Long descriptionThe Aeotec by Aeon Labs MultiSensor Gen5 looks like a motion sensor and it acts like one too. But it’s also so much more. Installing this 1 piece of Z-Wave technology is the same as installing 4 pieces of Z-Wave technology. Your home control network will immediately understand motion, temperature, humidity and light readings wherever Multisensor installed. Those intelligent readings will equate to intelligence automation. And intelligent automation will give you the perfect, smart home. Short descriptionAeon Labs MultiSensor Gen5 is a Z-Wave motion sensor, temperature sensor, humidity sensor, and lighting sensor all in one package. From to description 1431655765 1431655765 reset the product to default factory setting and be excluded from the z wave network. 1 1 resets all configuration parameters to default setting. 4 enable/disable the function of motion sensor. this parameter is used to enable/disable the function of motion sensor. 1. value=0, disable. 2. value=1, enable. 0 1 0 0 0 from to description 0 0 disable the function of motion sensor. 1 1 enable the function of motion sensor. 41 threshold change in temperature to induce an automatic report. threshold change in temperature to induce an automatic report. note: 1. when the unit is celsius, threshold=value. 2. when the unit is fahrenheit, threshold=value*1.8 the accuracy is 0.1. 0 2 0 0 1 from to description 0 65535 threshold of temperature. 112 the interval time of sending reports in report group 2. this parameter is used to configure the interval time of the sensor report in report group 2. the time unit is second. 0 4 0 0 1800 from to description 5 2678400 the range of interval time is 5 to 2678400. 3 timeout of the motion sensor this parameter is used to set the timeout for the motion sensor. note: (1), the time unit is second if the value range is in 1 to 255. (2), if the value range is in 256 to 15300, the time unit will be minute and its value should follow the below rules: a), interval time =value/60, if the interval time can be divided by 60 and without remainder. b), interval time= (value/60) +1, if the interval time can be divided by 60 and has remainder. (3), other values will be ignored. 0 2 0 0 240 from to description 1 255 the unit of timeout is second. 256 15300 the unit of timeout is minute. 113 the interval time of sending reports in report group 3 this parameter is used to configure the interval time of the sensor report in report group 3. the time unit is second. 0 4 0 0 1800 from to description 5 2678400 the range of interval time is 5 to 2678400. 252 enable/disable all configuration parameters to be locked this parameter is used to enable/disable all configuration parameters to be locked. (0 =disable, 1 = enable) 0 1 0 0 0 from to description 1 1 enable all configuration parameters to be locked. 0 0 disable all configuration parameters to be locked. 43 threshold change in luminance to induce an automatic report. threshold change in luminance to induce an automatic report. 0 2 0 0 100 from to description 0 1000 threshold of luminance 42 threshold change in humidity to induce an automatic report. threshold change in humidity to induce an automatic report. 0 2 0 0 5 from to description 0 100 threshold of humidity 111 the interval time of sending reports in report group 1 this parameter is used to configure the interval time of the sensor report in report group 1. the time unit is second. 0 4 0 0 1800 from to description 5 2678400 the range of interval time is 5 to 2678400. 44 threshold change in battery level to induce an automatic report. threshold change in battery level to induce an automatic report. 0 2 0 0 5 from to description 0 100 threshold of battery level. 5 which command would be sent when the motion sensor triggered. this parameter is used to configure that which command would be sent when the motion sensor triggered. 1. value=1, send basic set cc. 2. value=2, send sensor binary report cc. 0 1 0 0 1 from to description 2 2 send sensor binary report cc. 1 1 send basic set cc. 46 enable/disable to send the alarm report of low temperature this parameter is used to enable/disable to send the alarm report of low temperature(< 15℃) 1, value=0, disable. 2, value=1, enable (note: the multi sensor will report the multi level temperature cc with the value=0x ffff to controller if the current temperature is less than 15℃). 0 1 0 0 0 from to description 0 0 disable to send the alarm report of low temperature(&amp;amp;amp;amp;amp;amp;amp;amp;lt; 15℃) 1 1 enable to send the alarm report of low temperature(&amp;amp;amp;amp;amp;amp;amp;amp;lt; 15℃) 2 enable/disable waking up for 10 minutes when re power on (battery mode) the multi sensor. this parameter is used to enable/disable waking up for 10 minutes when re power on (battery mode) the multi sensor. 1. value = 0, disable. 2. value =others, enable. 0 1 0 0 0 from to description 0 0 disable waking up for 10 minutes when re power on (battery mode) the multi sensor. 1 1 enable waking up for 10 minutes when re power on (battery mode) the multi sensor. textsID Description Value 1