✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Aeotec shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Companion app is actively updated
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Aeotec Smart Dimmer 6 is a low-cost Z-Wave Dimmer plug-in module specifically used to enable Z-Wave command and control (on/off/dim) of any plug-in tool. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. Its surface has a Smart RGB LED, which can be used for indicating the output load status or strength of the wireless signal. You can configure its indication colour according to your favour. The Smart Dimmer 6 is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
Want to buy adds it to your wish list and follows Aeotec for updates. I own it adds it to your collection.
Aeotec Smart Dimmer 6 is a low-cost Z-Wave Dimmer plug-in module specifically used to enable Z-Wave command and control (on/off/dim) of any plug-in tool. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. Its surface has a Smart RGB LED, which can be used for indicating the output load status or strength of the wireless signal. You can configure its indication colour according to your favour. The Smart Dimmer 6 is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
Hardware platform
ZM5101
Short description
Smart Dimmer 6 is a plug-in on/off/dim switch module that also provides energy metering.
Association groups
Group Number Maximum Nodes Supported End Point ID Description 1
Product identifier
ZW099-C16
Countries / regions
European Union
Certification number
ZC10-15100026
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 3
Supports explorer frames
Yes
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
From to description 0 0 overload protection disabled 1 1 overload protection is enabled 92 induce an automatic report this parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in percentage. 0 1 0 0 5 from to description 0 100 the threshold can be set from 0 to 100 percent. 83 configure the led indication status when it is in night light mode this parameter is used to configure the led indication status when the current mode is night light mode. 0 4 0 0 1774619 from to description 65536 16777215 set the indication value of blue led. 0 255 set the indication value of red led. 256 65535 set the indication value of green led. 84 configure the brightness level for the led indication this parameter is used to configure the brightness level for the led indication. brightness level range is 0 to 100%. 0 1 0 0 50 from to description 0 100 brightness level range is 0 to 100%. 91 induce an automatic report this parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in wattage. 0 2 0 0 25 from to description 0 32767 the threshold can be set from 0 to 32767 watt. 112 set the interval time of sending report. this parameter is used to set the interval time of sending report in report group 2. (the unit of time is second). 0 4 0 0 600 from to description 0 268435456 interval seconds 113 set the interval time of sending report. this parameter is used to set the interval time of sending report in report group 3. (the unit of time is second). 0 4 0 0 600 from to description 0 268435456 interval seconds 200 partner id this parameter is used to configure the partner id. (0== aeon labs standard product, 1~255== others). 0 1 0 0 0 from to description 0 0 aeon labs standard product 1 255 partner id of partner product 103 to set which report need to be sent. this parameter is used to configure which reports need to be sent in report group 3. the values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent. for example, instantaneous current is the value 2 and instantaneous watts is the value 4, so setting parameter 103 to a value of 6 will result in both instantaneous current and instantaneous watts to be reported. see the full description of the parameter values for other possible settings. 0 4 0 0 0 from to description 2 2 report instantaneous current (amperes) 4 4 report instantaneous watts 8 8 report accumulated k wh 1 1 report instantaneous voltage 111 set the interval time of sending report. this parameter is used to set the interval time of sending report in report group 1. (the unit of time is second). 0 4 0 0 600 from to description 0 268435456 interval seconds 255 reset to default factory setting this parameter is used to reset product to default factory setting. (there are just 2 values can be used). 0 4 0 0 0 from to description 1431655765 1431655765 reset the product to default factory setting and be excluded from the z wave network. 1 1 reset all configuration parameters to default setting. 252 enable/disable lock configuration this parameter is used to enable/disable lock all configuration parameters. (0 =disable, 1 = enable) 0 1 0 0 0 from to description 0 0 all configuration parameters are configurable. 1 1 all configuration parameters are not configurable (locked). 254 device tag this parameter is used to save the device tag, which will be written/ assigned in factory/ manufacturer. 0 2 0 0 0 from to description 0 32767 device tag 90 enable/disable the function of parameter 91 and 92. this parameter is used to enable/disable the function of parameter 91 and 92 (1=enabled, 0=disabled). 0 1 0 0 1 from to description 0 0 configuration parameters 91 and 92 are disabled 1 1 configuration parameters 91 and 92 are enabled 80 enable/disable to send notifications to associated devices to associated devices. this parameter is used to enable/disable to send notifications to associated devices (in group 1) when the state of smart dimmer’s load is changed. (0=send nothing, 1=send hail cc, 2=send basic report cc). 0 1 0 0 0 from to description 0 0 send nothing (disabled) 1 1 send hail command 2 2 send basic report command 81 configure the state of led this parameter is used to configure the led state when the smart dimmer is in energy mode/momentary indicate mode/night light mode. 0 1 0 0 0 from to description 2 2 the state of led will the same with night light mode state configured by parameter 83. 0 0 the state of led will follow with the output load state(energy mode) 1 1 the state of led will follow with the output load state, but will turn off after 5 seconds if there is no any switch action.(momentary indicate mode) 102 to set which report need to be sent. this parameter is used to configure which reports need to be sent in report group 2. the values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent. for example, instantaneous current is the value 2 and instantaneous watts is the value 4, so setting parameter 102 to a value of 6 will result in both instantaneous current and instantaneous watts to be reported. see the full description of the parameter values for other possible settings. 0 4 0 0 0 from to description 1 1 report instantaneous voltage 4 4 report instantaneous watts 8 8 report accumulated k wh 2 2 report instantaneous current (amperes) 101 to set which report need to be sent. this parameter is used to configure which reports need to be sent in report group 1. the values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent. for example, instantaneous current is the value 2 and instantaneous watts is the value 4, so setting parameter 101 to a value of 6 will result in both instantaneous current and instantaneous watts to be reported. see the full description of the parameter values for other possible settings. 0 4 0 0 0 from to description 2 2 report instantaneous current (amperes) 4 4 report instantaneous watts 1 1 report instantaneous voltage 8 8 report accumulated k wh texts