Aeotec TriSensor is a universal Z-Wave Plus compatible product, consists of temperature, lighting and motion sensors, powered by a CR123A battery. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. By the built-in motion sensor, an alam will be sent to the gateway when the motion sensor is triggered.
Want to buy adds it to your wish list and follows Aeotec for updates. I own it adds it to your collection.
✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Aeotec shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Companion app is actively updated
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Aeotec TriSensor is a universal Z-Wave Plus compatible product, consists of temperature, lighting and motion sensors, powered by a CR123A battery. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. By the built-in motion sensor, an alam will be sent to the gateway when the motion sensor is triggered.
Hardware platform
ZM5101
Short description
Aeotec TriSensor has motion detector, ambient temperature and ambient light sensor in one which based on Z-Wave™Plus technology.
Product identifier
ZWA005-S
Countries / regions
Singapore
Certification number
ZC10-19026380
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported multilevel sensors
Multilevel Sensor Type Air temperature
Supported notification types
Notification Type Event / State Home Security
Value cr123 a color value white firmware updatable value updatable by consumer by rf sensors value motion/no motion (binary) air temperature luminance supported notification types value home security battery quantity value 1 association groups
Group Number Maximum Nodes Supported End Point ID Description 2
From to description 1 32767 unit: second. 7 temperature alarm value this parameter is configured the threshold value that alarm level for temperature. when the current ambient temperature value is larger than this configuration value, device will send a basic set = 0x ff to nodes associated in group 3. if current temperature value is less than this value, device will send a basic set = 0x00 to nodes associated in group 3. value = [value] × 0.1(celsius / fahrenheit) 0 2 0 0 239 from to description 400 850 value = [value] * 0.1(celsius / fahrenheit) 10 led indicate disable this parameter is configured the led light on disable or enable. ‘1’ – enable led blink when device detects a motion event. ‘0’ – disable led blink. this configuration is not affect inclusion, exclusion and reset. 0 1 0 0 1 from to description 0 1 ‘1’ – enable led blink when device detects a motion event. ‘0’ – disable led blink. this configuration is not affect inclusion, exclusion and reset. 11 led color for motion event report ‘0’ – disable. ‘0’ – disable. ‘1’ – red. ‘2’ –green. ‘3’ – blue. ‘4’ – yellow. ‘5’ – pink. ‘6’ – cyan. ‘7’ – purple. ‘8’ – orange. 0 1 0 0 2 from to description 0 8 ‘0’ – disable. ‘1’ – red. ‘2’ – green. ‘3’ – blue. ‘4’ – yellow. ‘5’ – pink. ‘6’ – cyan. ‘7’ – purple. ‘8’ – orange. 3 motion sensitivity this parameter is configured the sensitivity that motion detect. 0 – pir sensor disabled. 1 – lowest sensitivity. 11– highest sensitivity. 0 1 0 0 11 from to description 0 11 0 – pir sensor disabled. 1 – lowest sensitivity. 11– highest sensitivity. 4 binary sensor report enable ‘0’ –disable sensor binary report when motion event is detected or cleared. ‘1’ –enable sensor binary report when motion event is detected or cleared. 0 1 0 0 0 from to description 0 1 ‘0’ –disable sensor binary report when motion event is detected or cleared. ‘1’ –enable sensor binary report when motion event is detected or cleared. 6 basic set value settings for group 2 ‘0’ – send basic set = 0x ff to devices associated in group 2 when motion event is triggered, send basic set = 0x00 to devices associated in group 2 when motion event is cleared. ‘1’– send basic set = 0x00 to devices associated in group 2 when motion event is triggered, send basic set = 0x ff to devices associated in group 2 when motion event is cleared. ‘2’ – send basic set = 0x ff to devices associated in group 2 when motion event is triggered. ‘3’ – send basic set = 0x00 to devices associated in group 2 when motion event is triggered. ‘4’ – send basic set = 0x00 to devices associated in group 2 when motion event is cleared. ‘5’ – send basic set = 0x ff to devices associated in group 2 when motion event is cleared. 0 1 0 0 0 from to description 0 5 ‘0’ – send basic set = 0x ff to devices associated in group 2 when motion event is triggered, send basic set = 0x00 to devices associated in group 2 when motion event is cleared. ‘1’– send basic set = 0x00 to devices associated in group 2 when motion event is triggered, send basic set = 0x ff to devices associated in group 2 when motion event is cleared. ‘2’ – send basic set = 0x ff to devices associated in group 2 when motion event is triggered. ‘3’ – send basic set = 0x00 to devices associated in group 2 when motion event is triggered. ‘4’ – send basic set = 0x00 to devices associated in group 2 when motion event is cleared. ‘5’ – send basic set = 0x ff to devices associated in group 2 when motion event is cleared. 31 light intensity offset value the current measuring light intensity value can be add and minus a value by this setting. 0 2 0 0 0 from to description 1000 1000 scale: lux. 100 light sensor calibrated coefficient this configuration defines the calibrated scale for ambient light intensity. because the method and position that the sensor mounted and the cover of sensor will bring measurement error, user can get more real light intensity by this parameter setting. user should run the steps as blows for calibrating 1) set this parameter value to default (assumes the sensor has been added in a z wave network). 2) place a digital luxmeter close to sensor and keep the same direction, monitor the light intensity value (vm) which report to controller and record it. the same time user should record the value (vs) of luxmeter. 3) the scale calibration formula: k = vm / vs. 4) the value of k is then multiplied by 1024 and rounded to the nearest whole number. 5) set the value getting in 5) to this parameter, calibrate finished. for example, vm = 300, vs = 2600, then k = 2600 / 300 = 8.6667 k = 8.6667 * 1024 = 8874.7 ≈ 8875 the parameter should be set to 8875. 0 2 0 0 1024 from to description 1 32767 scale: lux. 23 temperature sensor report interval this parameter is configured the time interval for temperature sensor report. this value is larger, the battery life is longer. and the temperature value changed is not obvious. unit: second. 0 2 0 0 3600 from to description 1 32767 unit: second. 24 light sensor report interval this parameter is configured the time interval for light sensor report. this value is larger, the battery life is longer. and the light intensity changed is not obvious. unit: second. 0 2 0 0 3600 from to description 1 32767 unit: second. 5 disable basic set to associated nodes this parameter is configured the enabled or disabled send basic set command to nodes that associated in group 2 and group 3. 0 – disabled all group basic set command 1 – enabled group 2 basic set command, group 3 basic set command is disabled. 2 – enabled group 3 basic set command, group 2 basic set command is disabled. 3 – enabled group 2 and group 3 basic set command. 0 1 0 0 3 from to description 0 3 0 – disabled all group basic set command 1 – enabled group 2 basic set command, group 3 basic set command is disabled. 2 – enabled group 3 basic set command, group 2 basic set command is disabled. 3 – enabled group 2 and group 3 basic set command. texts