Long descriptionAeotec MultiSensor 7 is a sensor with ambient light/UV, temperature, humidity, vibration and motion. From to description 0 0 disable 1 11 sensitivity range 7 vibration intensity reports used to enable/disable vibration intensity reports. if set to 1, vibration intensity will be sent to gateway when triggered. if set to 0, do not report. 3 1 0 1 0 from to description 0 0 disable 1 0 enable 5 motion report type set which command class will be sent when motion sensor is triggered or detriggered. 0 sends notification report 1 sends sensor binary report 2 sends notification and sensor binary report 3 1 0 2 2 from to description 0 0 sends notification report 1 0 sends sensor binary report 2 0 sends notification and sensor binary report 6 vibration sensor enable/disable used to enable/disable vibration sensor. 0 disable vibration 1~254 timeout set in minutes to reset vibration status 255 timeout set in minutes to reset vibration status 2 1 0 255 255 from to description 0 0 disable vibration 1 254 timeout set in minutes to reset vibration status 255 255 timeout set in minutes to reset vibration status 10 power status this value is readonly. used to report the power status (usb or battery powered) 0 when battery powered, the device will act as rss. 1 when usb cable insert, the device will act as lss. the device must be re included in the network to change the role type. 3 1 0 1 0 from to description 0 0 when battery powered, the device will act as rss. 1 0 when usb cable insert, the device will act as lss. yes 17 under heat group threshold (group4) set threshold of temperature. designed to control air conditioners or temperature controllers on or off. if measured temperature (this value) send basic set (0x00) to associated devices. e.g. value 155 means 15.5 c. value 600 means 60.0 f. 1 2 400 850 155 from to description 400 850 set threshold of temperature 46 low temperature report eable/disable alarm report for low temperature( 3 1 0 1 1 from to description 0 0 disable 1 0 enable 41 temperature threshold threshold = (value * 0.1) scale is determined by param64. 0 = disable. 2 1 0 255 10 from to description 0 255 threshold = (value * 0.1) scale is determined by param64. 0 = disable. 42 humidity threshold humidity range = 1% to 50%, 0 = disable. 2 1 0 50 5 from to description 0 50 humidity range = 1% to 50%, 0 = disable. 43 lux threshold 0 = disable 2 2 0 10000 250 from to description 0 10000 lux threshold 44 uv threshold 0 = disable 2 1 0 11 1 from to description 0 11 uv threshold 45 threshold check time set threshold check time in seconds if threshold is enable via param40. 1~65535 when usb powered 60~65535 when battery powered 2 2 1 65535 240 from to description 1 65535 set threshold check time in seconds 50 temperature lower limit set lower limit level for temperature set in scale of 0.1. scale is determined by param64. if (current measurement) < (lower limit), then report sensor. 1 2 400 1000 0 from to description 400 1000 set lower limit level for temperature 49 temperature upper limit set upper limit level for temperature set in scale of 0.1. scale is determined by param64. if (current measurement) > (upper limit), then report sensor. 1 2 400 1000 280 from to description 400 1000 set upper limit level for temperature 61 out of limit state this is read only and bit mask. out of the limit state of sensors. bit mask: 0 within limit 1 out of limit value: 1 temperature upper level 2 humidity upper level 4 lux upper level 8 uv upper level 16 temperature lower level 32 humidity lower level 64 lux lower level 128 uv lower level 4 1 0 255 0 from to description 0 0 within limit 1 0 temperature upper level 2 0 humidity upper level 4 0 lux upper level yes 52 humidity upper limit set humidity upper limit level. 2 1 0 100 60 from to description 0 100 set humidity upper limit level. 54 humidity recover limit set humidity recover limit level. refer to param 51. 2 1 1 50 5 from to description 1 50 set humidity recover limit level 55 lux upper limit set lux upper limit level. 2 2 0 30000 1000 from to description 0 30000 set lux upper limit level. 56 lux lower limit set lux lower limit level. 2 2 0 30000 100 from to description 0 30000 set lux lower limit level. 58 uv upper limit set uv upper limit level. 2 1 1 11 8 from to description 1 11 set uv upper limit level. 59 uv lower limit set uv lower limit level. 2 1 1 11 4 from to description 1 11 set uv lower limit level. 60 uv recover limit set uv recover limit level. refer to param 51. 2 1 1 5 1 from to description 1 5 set uv recover limit level. 64 temperature scale set the scale for temperature when reports. 0 celsius 1 fahrenheit 3 1 0 1 0 from to description 0 0 celsius 1 0 fahrenheit 81 led activity allow user to enable/disable led activity of specific reports sent by sensor. button press indicator is not affected by this. 0 disable 1 enable 3 1 0 1 1 from to description 0 0 disable 1 0 enable 67 lux recover limit set lux recover limit level. refer to param 51. 2 1 1 255 100 from to description 1 255 set lux recover limit level. 88 battery report indicator if led is enabled by param81, allow user to change the report color of battery. 0 disabled 1 red 2 blue 3 green 4 pink 5 cyan 6 purple 7 orange 8 yellow 9 white 3 1 0 9 0 from to description 0 0 disable. other value descriptions, please see above description box of this parameter. 82 motion sensor report indicator if led is enabled by param81, allow user to change the report color of motion sensor. 0 disabled 1 red 2 blue 3 green 4 pink 5 cyan 6 purple 7 orange 8 yellow 9 white 3 1 0 9 3 from to description 8 0 yellow 9 0 white 6 0 purple 7 0 orange 0 0 disable 1 0 red 2 0 blue 3 0 green 4 0 pink 5 0 cyan 83 temperature sensor report indicator if led is enabled by param81, allow user to change the report color of temperature sensor. 0 disabled 1 red 2 blue 3 green 4 pink 5 cyan 6 purple 7 orange 8 yellow 9 white 3 1 0 9 0 from to description 0 0 disable. other value descriptions, please see above description box of this parameter. 84 humidity sensor report indicator if led is enabled by param81, allow user to change the report color of humidity sensor. 0 disabled 1 red 2 blue 3 green 4 pink 5 cyan 6 purple 7 orange 8 yellow 9 white 3 1 0 9 0 from to description 0 0 disable. other value descriptions, please see above description box of this parameter. 85 lux sensor report indicator if led is enabled by param81, allow user to change the report color of lux sensor. 0 disabled 1 red 2 blue 3 green 4 pink 5 cyan 6 purple 7 orange 8 yellow 9 white 3 1 0 9 0 from to description 0 0 disable. other value descriptions, please see above description box of this parameter. 86 uv sensor report indicator if led is enabled by param81, allow user to change the report color of uv sensor. 0 disabled 1 red 2 blue 3 green 4 pink 5 cyan 6 purple 7 orange 8 yellow 9 white 3 1 0 9 0 from to description 0 0 disable. other value descriptions, please see above description box of this parameter. 87 vibration sensor report indicator if led is enabled by param81, allow user to change the report color of vibration sensor. 0 disabled 1 red 2 blue 3 green 4 pink 5 cyan 6 purple 7 orange 8 yellow 9 white 3 1 0 9 2 from to description 0 0 disable. other value descriptions, please see above description box of this parameter. 89 wakeup report indicator if led is enabled by param81, allow user to change the report color of wakeup. 0 disabled 1 red 2 blue 3 green 4 pink 5 cyan 6 purple 7 orange 8 yellow 9 white 3 1 0 9 8 from to description 0 0 disable. other value descriptions, please see above description box of this parameter. 90 communication indicator if led is enabled by param81, allow user to change indicator color when receiving communication from gateway or other devices. 0 disabled 1 red 2 blue 3 green 4 pink 5 cyan 6 purple 7 orange 8 yellow 9 white 3 1 0 9 0 from to description 0 0 disable. other value descriptions, please see above description box of this parameter. 11 motion group control(group2) set control of other devices on group2 based on motion trigger. 0 send basic set (0x ff) when motion is triggered to associated device send basic set (0x00) when motion is untriggered to associated device 1 send basic set (0x00) when motion is triggered send basic set (0x ff) when motion is untriggered 2 send basic set (0x ff) when motion is triggered, nothing when motion untriggered. 3 send basic set (0x00) when motion is triggered, nothing when motion untriggered. 4 send basic set (0x00) when motion is untriggered, nothing when motion triggered. 5 send basic set (0x ff) when motion is untriggered, nothing when motion triggered. 6 send basic set (value is configured by parameter 12) when motion is triggered to associated devices. send basic set (value is configured by parameter 12) when motion is untriggered. 3 1 0 6 0 from to description 1 0 send basic set (0x00) when motion is triggered send basic set (0x ff) when motion is untriggered 2 0 send basic set (0x ff) when motion is triggered, nothing when motion untriggered. 3 0 send basic set (0x00) when motion is triggered, nothing when motion untriggered. 4 0 send basic set (0x00) when motion is untriggered, nothing when motion triggered. 5 0 send basic set (0x ff) when motion is untriggered, nothing when motion triggered. 6 0 send basic set (value is configured by parameter 12) when motion is triggered to associated devices. send basic set (value is configured by parameter 12) when motion is untriggered. 0 0 send basic set (0x ff) when motion is triggered to associated device send basic set (0x00) when motion is untriggered to associated device 204 uv offset value can add or minus this setting value to calibrate uv when checked. 1 1 10 10 0 from to description 10 10 offset value range 10 10. 1 beaming enable/disable used to enable/disable beaming. if set to 1, fli r commands will be supported. but the device must be re included into the network to activate it. 0 disable 1 enable 3 1 0 1 1 from to description 0 0 disable 1 0 enable 48 sensor limit control this value is bit mask. used to enable/disable measurement reports for various sensors that is more than the upper limit value or less than the lower limit value. 1 temperature upper level 2 humidity upper level 4 lux upper level 8 uv upper level 16 temperature lower level 32 humidity lower level 64 lux lower level 128 uv lower level 4 1 0 255 0 from to description 1 0 temperature upper level 0 0 disable 2 0 humidity upper level 103 automatic report checklist 3 checklist 3 for automatic timed report. when the corresponding item is selected, it will be checked when timeout setting by param113. 1 battery 16 uv 32 temperature 64 humidity 128 lux 4 1 0 241 0 from to description 1 0 battery. other value descriptions, please see above description box of this parameter. 201 temperature offset value can add or minus this setting value to calibrate temperature when checked. scale is defined by param64. e.g. value 15 means 1.5 c or 1.5 f. 1 2 200 200 0 from to description 200 200 temperature offset value 202 humidity offset value can add or minus this setting value to calibrate humidity when checked. unit: %. 1 1 100 100 0 from to description 100 100 humidity offset value 203 lux offset value can add or minus this setting value to calibrate lux when checked. 1 2 10000 10000 0 from to description 10000 10000 lux offset value textsID Description Value 8