From to description 1 1 trigger unable (default); trigger the relay and hub notification 0 0 trigger disable (only notification to hub according to set par 2) 6 ep1 auto turn off timer setting auto off timer value for relay one 2 4 0 65535 0 from to description 0 65535 ep1 auto turn off timer 1 restore state after power failure restore state after power failure: always off, always on or follow the status before power failure 2 1 0 4 1 from to description 0 0 all relays automatically turn off once power is restored 1 1 all relays remember the status prior to power outage and turns back to it 2 2 all relays turned on after power failure 3 3 r1 recovered, r2 on 4 4 r2 recovered, r1 – on 7 ep1 auto turn on timer setting auto on timer value for relay one 2 4 0 65535 0 from to description 0 65535 ep1 auto turn on timer 2 select switch one's type select switch one's type: switch or sensor 2 1 0 9 2 from to description 0 0 momentary switch 1 1 toggle switch (contact closed on, contact opened off) 2 2 toggle switch (device changes status when switch changes status) 3 3 garage door mode(toggle switch type for external switch (like in value 1) + built in 2 second auto off timer for z wave control (so if user turns the relay on from the z wave hub, it will automatically turn off after 2 seconds) 4 4 water alarm 5 5 heat alarm 6 6 smoke alarm 7 7 door alarm 8 8 co alarm 9 9 co2 alarm yes 3 select switch two's type select switch two's type: switch or sensor 2 1 0 9 2 from to description 0 0 momentary switch 1 1 toggle switch (contact closed on, contact opened off) 2 2 toggle switch (device changes status when switch changes status) 3 3 garage door mode(toggle switch type for external switch (like in value 1) + built in 2 second auto off timer for z wave control (so if user turns the relay on from the z wave hub, it will automatically turn off after 2 seconds) 4 4 water alarm 5 5 heat alarm 6 6 smoke alarm 7 7 door alarm 8 8 co alarm 9 9 co2 alarm yes 8 ep2 auto turn off timer setting auto off timer value for relay two 2 4 0 65535 0 from to description 0 65535 ep2 auto turn off timer 11 input 2 trigerring connect input and output or separate the output from the input for switch 2 2 1 0 1 1 from to description 0 0 trigger disable (only notification to hub according to set par 2) 1 1 trigger unable (default); trigger the relay and hub notification 9 ep2 auto turn on timer setting auto on timer value for relay two 2 4 0 65535 0 from to description 0 65535 ep2 auto turn on timer 5 led indicator indicator inverse, follow, always on or always off 2 1 0 3 0 from to description 0 0 led on when relay off, led off when relay on 1 1 led on when relay on, led off when relay off 2 2 led always off 3 3 led always on 24 sw1,sw2 setting dc motor mode: sync r1 and r2 together to prevent them from being activated at the same time 2 1 0 1 0 from to description 0 0 normal 1 1 union (only switch type1 < 4 && switch type2 < 4) if both switches off only one of them may be turned on. turning sw1 on : delayed 0.5 s, sw2 and r2 turned off first (immediately) turning sw2 on delayed 0.5s , sw1and r1 turned off first ( immediately ) the situation for dc motor control(sw1 control—right, sw2 control left. main switch can turn on and off only sw1 17 ep2 auto turn off timer unit setting auto off timer unit(minutes, seconds or hours) for relay two 2 1 0 2 0 from to description 2 2 hours 1 1 seconds 0 0 minutes textsID Description Value 8