Long descriptionSA301-1 has 3 sets of input terminals and 3 sets of relay output. Through the Universal Module, the Z-Wave Controller can read the input signal from wired sensors and control the output of wired actuators. This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufactures. All mains operated nodes within the network will act as repeater regardless of vender to increase reliability of the network. From to description 128 127 values from 128~127 will tell the device to active in3 mode 1 in1 mode size =1, default value = 0x40 bit 7:corresponds to values in config 4, 5 0 = trigger on when voltage under low threshold, trigger off when over hi threshold 1 = trigger on when voltage over hi threshold, trigger off when under low threshold bit 6:in1 3.3 v pull high on/off , 0 = off, 1 = on bit 5 4 : fixed at 0. bit 3:1 = activate out3 relay when in1 trigger bit 2:1 = activate out2 relay when in1 trigger bit 1:1 = activate out1 relay when in1 trigger bit 0:fixed at 0. 1 1 128 127 64 from to description 128 127 values from 128~127 will tell the device to active in1 mode 2 out1 relay trigger on time size =1, default value = 0x05 (500ms) step of 100ms, ‘0’ = remain on 1 1 128 127 5 from to description 128 127 relay 1 turn on period 3 group 2 turn on time when triggered by in1 size =1, default value = 0x b4 (off after 180 secs) step of 1 sec, ‘0’ = remain on 1 1 128 127 76 from to description 128 127 group 2 turn on period. 17 tamper mode size =1, default value = 0x00 bit 3:1 = activate out3 relay when tamper bit 2:1 = activate out2 relay when tamper bit 1:1 = activate out1 relay when tamper 1 1 0 7 0 from to description 0 7 0: no activate relay out; 1: activate out1 relay when tamper; 2: activate out2 relay when tamper; 3: activate out1 & out2 relay when tamper; 4: activate out3 relay when tamper; 5: activate out1 & out3 relay when tamper; 6: activate out2 & out3 relay when tamper; 7: activate out1 & out2 & out3 relay when tamper 6 in2 mode size =1, default value = 0x40 bit 7:corresponds to values in config 9, 10 0 = trigger on when voltage under low threshold, trigger off when over hi threshold 1 = trigger on when voltage over hi threshold, trigger off when under low threshold bit 6:in2 3.3 v pull high on/off , 0 = off, 1 = on bit 5 4 : fixed at 0. bit 3:1 = activate out3 relay when in2 trigger bit 2:1 = activate out2 relay when in2 trigger bit 1:1 = activate out1 relay when in2 trigger bit 0:fixed at 0. 1 1 128 127 64 from to description 128 127 values from 128~127 will tell the device to active in2 mode 4 in1 hi threshold voltage trigger level size =1, default value = 0x19 (in1 trigger off when over 2500m v). step of 100m v. 1 1 128 127 25 from to description 128 127 high threshold voltage level for trigger on (or trigger off, depending on mode). 5 in1 low threshold voltage trigger level size =1 default value = 0x a (in1 trigger on when under 1000m v) 1 1 128 127 10 from to description 128 127 low threshold voltage level for trigger on (or trigger off, depending on mode). 9 in2 hi threshold voltage trigger level size =1, default value = 0x19 (in2 trigger off when over 2500m v). step of 100m v. 1 1 128 127 25 from to description 128 127 high threshold voltage level for trigger on (or trigger off, depending on mode). 8 group 3 turn on time when triggered by in2 size =1, default value = 0x b4 (off after 180 secs) step of 1 sec, ‘0’ = remain on 1 1 128 127 76 from to description 128 127 group 3 turn on period. 7 out2 relay trigger on time size =1, default value = 0x05 (500ms) step of 100ms, ‘0’ = remain on 1 1 128 127 5 from to description 128 127 relay 2 turn on period 10 in2 low threshold voltage trigger level size =1 default value = 0x a (in2 trigger on when under 1000m v) 1 1 128 127 10 from to description 128 127 low threshold voltage level for trigger on (or trigger off, depending on mode). textsID Description Value 1