✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if FIBARO shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Be the first to start a thread about Smart Implant
Threads post into the FIBARO community forum.
Sign in to start a thread in the FIBARO community.
Edit history
Loading edit history…
Certified
FIBARO Smart Implant allows to enhance the functionality of wired sensors and other devices by adding Z-Wave network communication. You can connect binary sensors, analog sensors, DS18B20 temperature sensors or DHT22 humidity and temperature sensor to report their readings to the Z-Wave controller. It can also control devices by opening/closing output contacts independently of the inputs. Main features of FIBARO Smart Implant: - Compatible with any Z-Wave or Z-Wave Plus Controller, - Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 with PRNG-based encryption, - Allows for connecting sensors: o 6 DS18B20 sensors, o 1 DHT sensor, o 2 2-wire analog sensor, o 2 3-wire analog sensor, o 2 binary sensors. - Works as a Z-Wave signal repeater, - Built-in temperature sensor.
Want to buy adds it to your wish list and follows FIBARO for updates. I own it adds it to your collection.
FIBARO Smart Implant allows to enhance the functionality of wired sensors and other devices by adding Z-Wave network communication. You can connect binary sensors, analog sensors, DS18B20 temperature sensors or DHT22 humidity and temperature sensor to report their readings to the Z-Wave controller. It can also control devices by opening/closing output contacts independently of the inputs. Main features of FIBARO Smart Implant: - Compatible with any Z-Wave or Z-Wave Plus Controller, - Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 with PRNG-based encryption, - Allows for connecting sensors: o 6 DS18B20 sensors, o 1 DHT sensor, o 2 2-wire analog sensor, o 2 3-wire analog sensor, o 2 binary sensors. - Works as a Z-Wave signal repeater, - Built-in temperature sensor.
Hardware platform
ZM5101
Short description
FIBARO Smart Implant allows to enhance the functionality of wired sensors and other devices by adding Z-Wave network communication.
Product identifier
FGBS-222
Countries / regions
China
Supports smart start
Yes
Certification number
ZC10-20036877
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 25
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported multilevel sensors
Multilevel Sensor Type General purpose
Supported notification types
Notification Type Event / State Home Security
Value white sensors value open/closed (binary) general purpose supported notification types value home security system association groups
Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
From to description 1 1 reversed (out1 2nd output, out2 1st output) 0 0 default (out1 1st output, out2 2nd output) 41 input 2 sent scenes this parameter defines which actions result in sending scene id and attribute assigned to them (see 9: activating scenes). parameter is relevant only if parameter 20 is set to 2 or 3. 0 1 0 8 0 from to description 1 1 key pressed 1 time 2 2 key pressed 2 time 4 4 key pressed 3 time 8 8 key hold down and key released 49 input 1 value sent to 2nd association group when deactivated this parameter defines value sent to devices in 2nd association group when in1 input is deactivated (using basic command class). 0 2 0 255 0 from to description 0 255 value send to devices 52 input 2 value sent to 3rd association group when activated this parameter defines value sent to devices in 3rd association group when in2 input is triggered (using basic command class). 0 2 0 255 255 from to description 0 255 value send to devices 54 input 2 value sent to 3rd association group when deactivated this parameter defines value sent to devices in 2nd association group when in2 input is deactivated (using basic command class). 0 2 0 255 0 from to description 0 255 value send to devices 64 analog inputs periodical reports this parameter defines reporting period of analog inputs value. periodical reports are independent from changes in value (parameter 63). parameter is relevant only for analog inputs (parameter 20 or 21 set to 4 or 5). 0 2 0 32400 0 from to description 60 32400 (60s 9h) 0 0 periodical reports disabled 65 internal temperature sensor minimal change to report this parameter defines minimal change (from the last reported) of internal temperature sensor value that results in sending new report. 0 2 0 255 5 from to description 1 255 (0.1 25.5°c) 0 0 reporting on change disabled 66 internal temperature sensor periodical reports this parameter defines reporting period of internal temperature sensor value. periodical reports are independent from changes in value (parameter 65). 0 2 0 32400 0 from to description 60 32400 (60s 9h) 0 0 periodical reports disabled 67 external sensors minimal change to report this parameter defines minimal change (from the last reported) of external sensors values (ds18 b20 or dht22) that results in sending new report. parameter is relevant only for connected ds18 b20 or dht22 sensors. 0 2 0 255 5 from to description 1 255 (0.1 25.5 units, 0.1) 0 0 reporting on change disabled 68 external sensors periodical reports this parameter defines reporting period of analog inputs value. periodical reports are independent from changes in value (parameter 67). parameter is relevant only for connected ds18 b20 or dht22 sensors. 0 2 0 32400 0 from to description 60 32400 (60s 9h) 0 0 periodical reports disabled 150 input 1 sensitivity this parameter defines the inertia time of in1 input in alarm modes. adjust this parameter to prevent bouncing or signal disruptions.parameter is relevant only if parameter 20 is set to 0 or 1 (alarm mode). 0 1 0 100 10 from to description 1 100 (10ms 1000ms, 10ms step) 151 input 2 sensitivity this parameter defines the inertia time of in2 input in alarm modes. adjust this parameter to prevent bouncing or signal disruptions. parameter is relevant only if parameter 21 is set to 0 or 1 (alarm mode). 0 1 0 100 10 from to description 1 100 (10ms 1000ms, 10ms step) 152 input 1 delay of alarm cancellation this parameter defines additional delay of cancelling the alarm on in1 input. parameter is relevant only if parameter 20 is set to 0 or 1 (alarm mode). 0 2 0 3600 0 from to description 1 3600 (in seconds) 0 0 no delay 153 input 2 delay of alarm cancellation this parameter defines additional delay of cancelling the alarm on in2 input. parameter is relevant only if parameter 21 is set to 0 or 1 (alarm mode). 0 2 0 3600 0 from to description 1 3600 (in seconds) 0 0 no delay 154 output 1 logic of operation this parameter defines logic of out1 output operation. 0 1 0 1 0 from to description 1 1 contacts normally closed / open when active 0 0 contacts normally open / closed when active 155 output 2 logic of operation this parameter defines logic of out2 output operation. 0 1 0 1 0 from to description 1 1 contacts normally closed / open when active 0 0 contacts normally open / closed when active 156 output 1 auto off this parameter defines time after which out1 will be automatically deactivated. 0 2 0 27000 0 from to description 1 27000 (0.1s 45min, 0.1s step) 0 0 auto off disabled 157 output 2 auto off this parameter defines time after which out2 will be automatically deactivated. 0 2 0 27000 0 from to description 1 27000 (0.1s 45min, 0.1s step) 0 0 auto off disabled 24 inputs orientation this parameter allows reversing operation of in1 and in2 inputs without changing the wiring. use in case of incorrect wiring. 0 1 0 1 0 from to description 1 1 reversed (in1 2nd input, in2 1st input) 0 0 default (in1 1st input, in2 2nd input) 47 input 1 value sent to 2nd association group when activated this parameter defines value sent to devices in 2nd association group when in1 input is triggered (using basic command class). 0 2 0 255 255 from to description 0 255 value send to devices 63 analog inputs minimal change to report this parameter defines minimal change (from the last reported) of analog input value that results in sending new report. parameter is relevant only for analog inputs (parameter 20 or 21 set to 4 or 5). 0 1 0 100 5 from to description 1 100 (0.1 10 v, 0.1 v step) 0 0 reporting on change disabled texts