FIBARO CO Sensor is an ultra-light, compact, battery-powered carbon monoxide detector, designed to be placed on a wall. Its high sensitivity allows to detect the presence of the carbon monoxide (CO) gas at the early stage in order to prevent carbon monoxide poisoning. Alarm is signalled with a built-in siren, blinking LED indicator and by sending commands to Z-Wave network devices. Additionally, the device is equipped with a temperature sensor.
Want to buy adds it to your wish list and follows FIBARO for updates. I own it adds it to your collection.
✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if FIBARO shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
FIBARO CO Sensor is an ultra-light, compact, battery-powered carbon monoxide detector, designed to be placed on a wall. Its high sensitivity allows to detect the presence of the carbon monoxide (CO) gas at the early stage in order to prevent carbon monoxide poisoning. Alarm is signalled with a built-in siren, blinking LED indicator and by sending commands to Z-Wave network devices. Additionally, the device is equipped with a temperature sensor.
Hardware platform
ZM5101
Short description
FIBARO CO Sensor is a compact, wall-mounted, battery-powered carbon monoxide detector.
Product identifier
FGCD-001
Countries / regions
Australia
Certification number
ZC10-19076622
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_SENSOR_ALARM
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported multilevel sensors
Multilevel Sensor Type Air temperature
Supported notification types
Notification Type Event / State CO Alarm
Value 1 battery type value cr123 a color value white firmware updatable value updatable by consumer by rf sensors value air temperature carbon monoxide supported notification types value co alarm association groups
Group Number Maximum Nodes Supported End Point ID Description 1
From to description 0 0 both actions disabled 1 1 tampering (opened casing) 2 2 exceeding the temperature 3 3 both actions enabled 3 led diode indications this parameter allows to set the actions which result in led diode indications. this parameter does not apply to the most important actions, such as co alarm, malfunction alarm and low battery alarm. 0 1 0 0 0 from to description 0 0 all actions disabled 1 1 tampering (opened casing) 2 2 exceeding the temperature 4 4 lack of z wave range 4 acoustic signals this parameter allows to set the actions which result in acoustic signals. this parameter does not apply to the most important actions, such as co alarm, malfunction alarm and low battery alarm. 0 1 0 0 0 from to description 0 0 all actions disabled 1 1 tampering (opened casing) 2 2 exceeding the temperature 4 4 lack of z wave range 10 commands sent to 2nd association group (co alarm) this parameter defines commands sent to devices associated in 2nd association group (co alarm). values of specified commands may be set in parameters 11 and 12. 0 1 0 0 3 from to description 1 1 basic on 2 2 basic off 3 3 basic on & basic off 11 value of basic on command sent to 2nd association group this parameter defines the value of basic on command sent to devices in 2nd association group after the co alarm activation. 1 99 forcing level of associated devices 255 setting associated devices to the last remembered state or turning them on 0 2 0 0 255 from to description 0 99 forcing level of associated devices 255 255 setting associated devices to the last remembered state or turning them on 17 co level required for sending basic off command to 4th association group this parameter defines the maximum level of co concentration below which falling will result in starting the timer set in parameter 18. 0 2 0 0 25 from to description 10 400 co concentration level in ppm 23 co meter activation this parameter activates reporting the value of co concentration level to the main z wave controller. 0 1 0 0 1 from to description 0 0 disabled 1 1 enabled 25 co level reporting hysteresis this parameter defines a minimum change in co concentration level which results in sending a new value to the main z wave controller. 0 1 0 0 2 from to description 2 6 10 ppm 30 ppm, each 5 ppm texts