✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if FIBARO shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Community photos
Photos from members
No member photos yet.
Reviews
What members say
Sign in to rate FIBARO Smoke Sensor and share a photo.
No reviews yet.
Community
Be the first to start a thread about FIBARO Smoke Sensor
Threads post into the FIBARO community forum.
Sign in to start a thread in the FIBARO community.
Edit history
Loading edit history…
Certified
The FIBARO Smoke Sensor is a universal, ultra-light, perfectly designed, optical Z-Wave smoke detector. Fire alarm is signaled by sound, visual indicator blinking and alarm reports sent to the other devices within Z-wave network. The optical sensor detects smoke at an early stage of fire, often before flames appear and temperature starts to rise significantly. Moreover, the device has a built-in temperature sensor, which is adjustable to allow detection of fire by exceeding given temperature threshold. The FIBARO Smoke Sensor is a battery powered device designed to be placed on the wall or ceiling. Visual indicator signals fire, operating mode and it is used to check if the device is within the Z-wave network using a built-in Z-Wave range tester. The Smoke Sensor is designed to operate in confined spaces, under normal conditions (lacking of smoke, dust or condensed water vapor). Product video: https://www.youtube.com/watch?v=50QGfkdUtns
Want to buy adds it to your wish list and follows FIBARO for updates. I own it adds it to your collection.
The FIBARO Smoke Sensor is a universal, ultra-light, perfectly designed, optical Z-Wave smoke detector. Fire alarm is signaled by sound, visual indicator blinking and alarm reports sent to the other devices within Z-wave network. The optical sensor detects smoke at an early stage of fire, often before flames appear and temperature starts to rise significantly. Moreover, the device has a built-in temperature sensor, which is adjustable to allow detection of fire by exceeding given temperature threshold. The FIBARO Smoke Sensor is a battery powered device designed to be placed on the wall or ceiling. Visual indicator signals fire, operating mode and it is used to check if the device is within the Z-wave network using a built-in Z-Wave range tester. The Smoke Sensor is designed to operate in confined spaces, under normal conditions (lacking of smoke, dust or condensed water vapor).
Hardware platform
ZM5202
Short description
A battery powered smoke detector which gives protection from flaming and smoldering fires.
Product identifier
FGSD-002
Countries / regions
Russian Federation
Certification number
ZC10-17015392
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_SENSOR_ALARM
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported multilevel sensors
Multilevel Sensor Type Air temperature
Value 1 battery type value cr123 a firmware updatable value updatable by consumer by rf sensors value air temperature smoke density association groups
Group Number Maximum Nodes Supported End Point ID Description 1
From to description 1 1 casing opening notification enabled 0 0 all notifications disabled 2 2 exceeding temperature threshold notification enabled 1 fibaro smoke sensor sensitivity there are 3 levels of sensitivity to smoke presence. level 1 means the highest sesitivity. rising the parameter value lowers the sensitivity to smoke presence. available settings: 1 3 1 high sensitivity 2 medium sensitivity 3 low sensitivity 0 1 0 0 2 from to description 2 2 medium sensitivity 1 1 high sensitivity 3 3 low sensitivity 31 excess temperature signaling interval time interval of signaling (visual indication/sound) excess temperature level. available setting: 1 8640 (multiply by 10 seconds) [10s 24 h] 1 8640 [10s 24h] caution parameter 31 is associated with parameters 2, 3 and 4 settings. their modification may have no effect if configured functionality is not activated in the corresponding parameter. 0 2 0 0 1 from to description 1 8640 [10s 24h] 10 configuration of control frames in basic command class this parameter defines which frames will be sent in the 2 nd association group (smoke alarm). the values of basic on and basic off frames may be defined as described in further parameters. available settings: 0 2 0 basic on & basic off enabled 1 basic on enabled 2 basic off enabled 0 1 0 0 0 from to description 0 0 basic on & basic off enabled 1 1 basic on enabled 2 2 basic off enabled 11 basic on frame value basic on frame is sent in case of smoke presence detection and fire alarm triggering. its value is defined by the parameter. available setting: 0 99, 255 0 turn off the device 1 99 set the device to 1 99 % 255 set the last status 0 2 0 0 255 from to description 0 0 basic off enabled 1 99 set the device to 1 99 % 255 255 set the last status 3 visual indicator notifications status this parameter allows to activate visual indications but does not apply to major alarms, such as fire, trouble and low battery alarm. available settings: 0 7 0 all notifications disabled 1 casing opening notification enabled 2 exceeding temperature threshold notification enabled 4 lack of z wave range notification parameter values may be combined, e.g. 1+2+4=7, means that all notifications are enabled. 0 1 0 0 0 from to description 1 1 casing opening notification enabled 2 2 exceeding temperature threshold notification enabled 0 0 all notifications disabled 4 4 lack of z wave range notification 4 saund notifications status this parameter allows to activate sound signals but does not apply to major alarms, such as fire, trouble and low battery alarm. available settings: 0 7 0 all notifications disabled 1 casing opening notification enabled 2 exceeding temperature threshold notification enabled 4 lack of z wave range notification parameter values may be combined, e.g. 1+2+4=7, means that all notifications are enabled. 0 1 0 0 0 from to description 4 4 lack of z wave range notification 0 0 all notifications disabled 1 1 casing opening notification enabled 2 2 exceeding temperature threshold notification enabled texts