The MIMO2+ module provides two voltage inputs and two relay outputs (either can be wired normally open or normally closed). Z-Wave™ messages can be used to read the inputs and control the outputs. The inputs are very configurable for different trigger conditions and can even be mapped to control the outputs. The module includes a button for Z-Wave™ inclusion/exclusion and an LED for various status indications. The functionality of the SIG1 and SIG2 inputs is: - Analog Triggering: Various trigger conditions can be set for high-to-low and low-to-high transitions. This provides great flexibility for capturing digital or analog events in a wide variety of applications. The trigger status can be automatically sent to the controller. - Associations: Each input can be associated with up to two other Z-Wave™ devices, so that, for example, an associated device will automatically turn on (or off) based on the occurrence of a trigger event. Voltage Reporting: The analog input voltage levels can also be sent to the controller. The physical outputs are relays that are typically activated by Z-Wave™ commands. However, the user can override Z-Wave™ control by configuring the input trigger conditions to be mapped to the output relays via logical AND/OR functions.
Long descriptionThe MIMO2+ module provides two voltage inputs and two relay outputs (either can be wired normally open or normally closed). Z-Wave™ messages can be used to read the inputs and control the outputs. The inputs are very configurable for different trigger conditions and can even be mapped to control the outputs. The module includes a button for Z-Wave™ inclusion/exclusion and an LED for various status indications. The functionality of the SIG1 and SIG2 inputs is: - Analog Triggering: Various trigger conditions can be set for high-to-low and low-to-high transitions. This provides great flexibility for capturing digital or analog events in a wide variety of applications. The trigger status can be automatically sent to the controller. - Associations: Each input can be associated with up to two other Z-Wave™ devices, so that, for example, an associated device will automatically turn on (or off) based on the occurrence of a trigger event. Voltage Reporting: The analog input voltage levels can also be sent to the controller. The physical outputs are relays that are typically activated by Z-Wave™ commands. However, the user can override Z-Wave™ control by configuring the input trigger conditions to be mapped to the output relays via logical AND/OR functions. Value updatable by consumer by rf switch load capacity current value 10 a / 24 vdc (relays) switch load capacity volt ampere value 16 v (inputs / signal), 24 v (outputs / relays) sensors value motion/no motion (binary) open/closed (binary) switch type value dry contact association groupsGroup Number Maximum Nodes Supported End Point ID Description 1 From to description 128 127 set this value to trigger between thresholds 4 sig 1 lower threshold, high (must be less than upper threshold low and greater than lower threshold low) reference technical appendix triggering notes for visual's. (signed value in the range 0 to 255; convert values over 127 to a signed 1 byte value, or if your controller supports entering the value in hexadecimal you may use the hex value.) 0 1 0 0 112 from to description 128 127 set this value to set the lower threshold high number 6 sig 1 upper threshold, high sig1 upper threshold, high use this to set the upper threshold high number. reference technical appendix triggering notes for visual's. (signed value in the range 0 to 255; convert values over 127 to a signed 1 byte value, or if your controller supports entering the value in hexadecimal you may use the hex value.) 0 1 0 0 1 from to description 128 127 set this to set the upper threshold, high number 9 sig 2 multilevel trigger settings b7: trigger between thresholds (1=true) b6: periodic sends (=0) or send when change of trigger (=1) b5 b0: periodic send interval for lifeline (30s resolution, 0=no periodic sends) reference technical appendix triggering notes for visual's. (signed value in the range 0 to 255; convert values over 127 to a signed 1 byte value, or if your controller supports entering the value in hexadecimal you may use the hex value.) 0 1 0 0 88 from to description 128 127 set this value to trigger between thresholds 5 sig 1 lower threshold, low sig 1 lower threshold, low reference technical appendix triggering notes for visual's. (signed value in the range 0 to 255; convert values over 127 to a signed 1 byte value, or if your controller supports entering the value in hexadecimal you may use the hex value.) 0 1 0 0 128 from to description 128 127 set this to set the lower threshold low number. 10 sig 2 lower threshold, high (must be less than upper threshold low and greater than lower threshold low) reference technical appendix triggering notes for visual's. (signed value in the range 0 to 255; convert values over 127 to a signed 1 byte value, or if your controller supports entering the value in hexadecimal you may use the hex value.) 0 1 0 0 112 from to description 128 127 set this value to set the lower threshold high number 1 relay 1 configuration this sets the configuration of relay 1 to be latching, or to toggle back to off/open after a specified amount of time. (signed value in the range 0 to 255; convert values over 127 to a signed 1 byte value, or if your controller supports entering the value in hexadecimal you may use the hex value.) 0 1 0 0 0 from to description 128 127 set this value to the amount of time in 100ms increments for the relay to remain closed/on before automatically returning to the open/off state. for example, a value of 2 = 0.2 seconds. 0 0 the relay will remain latched in the position it is commanded to (open/off or closed/on) 2 relay 2 configuration this sets the configuration of relay 2 to be latching, or to toggle back to off/open after a specified amount of time. (signed value in the range 0 to 255; convert values over 127 to a signed 1 byte value, or if your controller supports entering the value in hexadecimal you may use the hex value.) 0 1 0 0 5 from to description 128 127 set this value to the amount of time in 100ms increments for the relay to remain closed/on before automatically returning to the open/off state. for example, a value of 2 = 0.2 seconds. 0 0 the relay will remain latched in the position it is commanded to (open/off or closed/on) 7 sig 1 upper threshold, low (must be greater than lower threshold high and less than upper threshold high) reference technical appendix triggering notes for visual's. (signed value in the range 0 to 255; convert values over 127 to a signed 1 byte value, or if your controller supports entering the value in hexadecimal you may use the hex value.) 0 1 0 0 2 from to description 128 127 set this to set the upper threshold low number 11 sig 2 lower threshold, low sig 2 lower threshold, low reference technical appendix triggering notes for visual's. (signed value in the range 0 to 255; convert values over 127 to a signed 1 byte value, or if your controller supports entering the value in hexadecimal you may use the hex value.) 0 1 0 0 128 from to description 128 127 set this to set the lower threshold low number. textsID Description Value 1