Long descriptionThe Inovelli dimmer switch is a Z-Wave in-wall dimmer that controls attached LED, CFL, & Incandescent lighting which can be highly customized to your liking at the switch itself with our unique config button and advanced firmware. The switch can also be used either with or without a neutral wire. Short descriptionThe Inovelli dimmer switch is a Z-Wave Plus switch equipped with S2 Encryption, SmartStart, allows full customization via our config button and has an RGB LED Bar. From to description 0 0 disabled 1 1 enabled 8 auto off timer automatically turns the switch off after x amount of seconds. example of how the values are used: 0 = disabled, 1 = 1 second, 32767 = 32767 seconds. 0 2 0 0 0 from to description 0 32767 automatically turns off after so many seconds 17 timeout for led notifications changes the amount of time the rgb bar shows the dim level if the led bar has been disabled. example of how the values are used: 0 = always off, 1 = 1 second after level is adjusted, 10 = 10 seconds after level is adjusted. 0 1 0 0 3 from to description 0 0 always off 1 10 seconds after dim level is adjusted 1 dimming speed how fast or slow the light turns on when you hold the switch (ie: dimming from 10 20%, 80 60%, etc). example of how the values are used: 0 = instant on, 1 = 1 second, 100 = 100 seconds. this parameter can be changed at the config button. note if using a dumb switch: this parameter will not work when pressing the dumb switch manually. 0 1 0 0 3 from to description 0 100 seconds 4 ramp rate (z wave) how fast or slow the light turns on when you turn on or off the switch remotely to bring from on to off or off to on. example of how the values are used: 0 = instant on, 1 = 1 second, 100 = 100 seconds. a value of 101 keeps this parameter in sync with parameter 1. 0 1 0 0 101 from to description 101 101 keeps in sync with parameter 1 0 0 instant on 1 100 seconds 3 ramp rate how fast or slow the light turns on when you press the switch 1x to bring from on to off or off to on. example of how the values are used: 0 = instant on, 1 = 1 second, 100 = 100 seconds. a value of 101 keeps this parameter in sync with parameter 1. 0 1 0 0 101 from to description 101 101 keeps in sync with parameter 1 0 0 instant on 1 100 seconds 10 default level (z wave) default dim level for the switch when controlled remotely (via an app or voice control). example of how the values are used: 0 = switch will return to level it was prior to being off, 1 = 1%, 100 = 100%. this parameter can be changed at the config button. 0 1 0 0 0 from to description 1 100 percentage 0 0 previous level 11 power on state when power is restored, the switch reverts to either on, off, or last level. example of how the values are used: 0 = off, 1 100 = specific % on. entering a value of 101 = returns the switch to the level before the power outage. this parameter can be changed at the config button. 0 1 0 0 0 from to description 101 101 turns on to last percentage level 0 0 off 1 100 turns on to a specific percentage level 5 minimum dim level minimum level the light switch will dim to (great for fixing flickering bulbs). example of how the values are used: 1= 1%, 2 = 2%, 45 = 45%. this parameter can be changed at the config button. 0 1 0 0 1 from to description 1 45 percentage 6 maximum dim level maximum level the light switch will dim to. example of how the values are used: 55= 55%, 56 = 56%, 100 = 100%. this parameter can be changed at the config button. 0 1 0 0 1 from to description 55 100 percentage 9 default level (local) default dim level for the switch when pressed locally (at the switch). example of how the values are used: 0 = switch will return to level it was prior to being off, 1 = 1%, 100 = 100%. this parameter can be changed at the config button. 0 1 0 0 0 from to description 0 0 previous level 1 100 percentage 2 dimming speed (z wave) how fast or slow the light turns on when you dim the switch remotely (ie: dimming from 10 20%, 80 60%, etc). example of how the values are used: 0 = instant on, 1 = 1 second, 100 = 100 seconds. a value of 101 keeps this parameter in sync with parameter 1. 0 1 0 0 101 from to description 1 100 seconds 101 101 keeps in sync with parameter 1 0 0 instant on textsID Description Value 6