The Multi sensor is designed for use with scenes in home automation systems, integrate motion, light, temperature and humidity sensors, powered by CR123A battery or USB cable. The Motion Sensor lets you know when movement is detected in a certain area and can trigger different actions in response to that movement (or lack of movement). It also lets you know the ambient temperature and humidity to trigger different actions to make you more comfort.
Want to buy adds it to your wish list and follows LEEDARSON for updates. I own it adds it to your collection.
✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if LEEDARSON shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
The Multi sensor is designed for use with scenes in home automation systems, integrate motion, light, temperature and humidity sensors, powered by CR123A battery or USB cable. The Motion Sensor lets you know when movement is detected in a certain area and can trigger different actions in response to that movement (or lack of movement). It also lets you know the ambient temperature and humidity to trigger different actions to make you more comfort.
Hardware platform
ZM5101
Short description
The Multi sensor is designed for use with scenes in home automation systems, integrate motion, light, temperature and humidity sensors, powered by CR123A battery or USB cable.
Product identifier
7A-SS-AABC-H0
Countries / regions
United States of America
Supports smart start
Yes
Certification number
ZC10-18066140
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 10
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported multilevel sensors
Multilevel Sensor Type Air temperature
Supported notification types
Notification Type Event / State Light sensor
Value updatable by consumer by rf sensors value motion/no motion (binary) air temperature luminance humidity battery quantity value 1 battery type value cr123 a supported notification types value luminance association groups
Group Number Maximum Nodes Supported End Point ID Description 2
From to description 10 50 low battery power level of alarm threshold values 100 set 101 ~ 104 to default. set 101 ~ 104 to default. 0 1 0 0 0 from to description 0 255 set 101 ~ 104 to default. 113 configuration luminance change threshold. configuration luminance change threshold. valid values: 1 65528(unit lx) 0 2 0 0 150 from to description 32767 1 luminance change threshold is 32767 to 65528 0 32766 luminance change threshold is 0 to 32766 103 the interval time of sending the luminance reporting. the interval time of sending the luminance reporting. if setting to 0 then the luminance reporting is disabled 1. valid values: 0x00 0x28 de80 2. the minimum interval time is 1 minutes. for example, if the value is set to be more than 1 and less than 60, the interval time is 1 minutes, if the value is set to be more than 60 and less than 120, the interval time is 2 minutes. 0 4 0 0 7200 from to description 0 0 the luminance reporting is disabled 1 2678400 the interval time of sending the luminance reporting is 31 days(2678400 seconds) 102 the interval time of sending the humidity reporting. the interval time of sending the humidity reporting. if setting to 0 then the humidity reporting is disabled 1. valid values: 0x00 0x28 de80 2. the minimum interval time is 1 minutes. for example, if the value is set to be more than 1 and less than 60, the interval time is 1 minutes, if the value is set to be more than 60 and less than 120, the interval time is 2 minutes. 0 4 0 0 7200 from to description 0 0 the humidity reporting is disabled 1 2678400 the interval time of sending the humidity reporting is 31 days(2678400 seconds) 104 the interval time of sending the battery level reporting. the interval time of sending the battery level reporting. if setting to 0 then the battery level reporting is disabled 1. valid values: 0x00 0x28 de80 2. the minimum interval time is 1 minutes. for example, if the value is set to be more than 1 and less than 60, the interval time is 1 minutes, if the value is set to be more than 60 and less than 120, the interval time is 2 minutes. 0 4 0 0 86400 from to description 0 0 the battery level reporting is disabled 1 2678400 the interval time of sending the battery level reporting is 31 days(2678400 seconds) 110 enable 111 ~ 114 temperature/humidity/luminance/ battery level change reporting. enable 111 ~ 114 temperature/humidity/luminance/ battery level change reporting. 0 = unable 1 = enable 0 1 0 0 0 from to description 0 0 unable 1 1 enable 111 configuration temperature change threshold. configuration temperature change threshold. valid values: 1 500(unit 0.1℃) 0 2 0 0 10 from to description 1 500 the temperature change threshold value(unit 0.1℃) 114 configuration battery level change threshold. configuration battery level change threshold. valid values: 1 100(unit %) 0 1 0 0 10 from to description 1 100 battery level change threshold value(unit)% 101 the interval time of sending the temperature reporting the interval time of sending the temperature reporting. if setting to 0 then the temperature reporting is disabled 1. valid values: 0x00 0x28 de80 2. the minimum interval time is 1 minutes. for example, if the value is set to be more than 1 and less than 60, the interval time is 1 minutes, if the value is set to be more than 60 and less than 120, the interval time is 2 minutes. 0 4 0 0 7200 from to description 0 0 the temperature reporting is disabled 1 2678400 the interval time of sending the temperature reporting is 31 days(2678400 seconds) texts