✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if MCO Home shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Community photos
Photos from members
No member photos yet.
Reviews
What members say
Sign in to rate 9 in 1 MULTI-SENSOR and share a photo.
No reviews yet.
Community
Be the first to start a thread about 9 in 1 MULTI-SENSOR
Threads post into the MCO Home community forum.
Sign in to start a thread in the MCO Home community.
Edit history
Loading edit history…
Certified
The MCOHome A8-9 is a Z-Wave enabled multi-sensor that can completely monitor your environment and assist with all of your smart home needs. The 3.5 inch touch-screen display allows you to see the sensor information that is also reported to your Z-Wave gateway. The A8-9 includes temperature, humidity, motion and light level like many sensors, but goes far beyond by also providing particular matter (pollution), carbon dioxide, and volatile organic compound levels as well. Security and safety is further enhanced with a noise sensor and smoke detection providing an amazing NINE different sensors in one package.
Want to buy adds it to your wish list and follows MCO Home for updates. I own it adds it to your collection.
MCOHome A8-9 is a Z-Wave™ enabled multiple environmental monitoring sensor, with 3.5 inch TFT clear display and compliant to Z-Wave Plus™ standard. It is built in with Temperature, Humidity, PM2.5, CO2, VOC, PIR, illumination, Noise, Smoke sensor. Device can be added into any Z-Wave™ network, and is compatible with any other Z-Wave™ certified devices.
Hardware platform
ZM5202
Short description
MCOHome A8-9 is a Z-Wave™ enabled multiple environmental monitoring sensor.
Product identifier
A8-9
Countries / regions
United States of America
Certification number
ZC10-20096971
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 6
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Supported multilevel sensors
Multilevel Sensor Type Illuminance
Value white association groups
Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
From to description 0 32767 value=0 indicates turn off report , value>=1 indicates to report current illumination value when change >n*1 lux 1 parameter 1 this is the pm2.5 delta level which determine when to report the current pm2.5 value. 1 1 0 127 0 from to description 0 127 value=0 indicates turn off report , value>=1 indicates to report current pm2.5 value when change > n * 1ug/m3 9 parameter 9 this is the smoke delta level which determines when to report the current smoke value. 1 1 0 1 1 from to description 0 1 value=0 indicates turn off report , value=1 indicates report change 3 parameter 3 this is the temperature delta level which determines when to report the current temperature value. 1 1 0 127 0 from to description 0 127 value=0 indicates turn off report , value>=1 indicates to report current temperature value when change > n * 0.5℃ 7 parameter 7 this is the d b delta level which determines when to report the current noise value. 1 1 0 127 0 from to description 0 127 value=0 indicates turn off report , value>=1 indicates to report current noise value when change >n*1 d b 4 parameter 4 this is the humidity delta level which determines when to report the current humidity value. 1 1 0 127 0 from to description 0 127 value=0 indicates turn off report , value>=1 indicates to report current humidity value when change >n% 8 parameter 8 this is the pir delta level which determines when to report the current pir value. 1 1 0 1 0 from to description 0 1 value=0 indicates turn off report , value=1 indicates report change 5 parameter 5 this is the voc delta level which determines when to report the current voc value. 1 1 0 127 0 from to description 0 127 value=0 indicates turn off report , value>=1 127*5ppb report change 2 parameter 2 this is the co2 delta level which determines when to report the current co2 value. 1 1 0 127 0 from to description 0 127 value=0 indicates turn off report , value>=1 indicates to report current co2 value when change > n * 5ppm texts