NEVOTON DCM-5.1.1-Z - is a Z-Wave device which is intended for industrial and household sensors with electrical outputs of different types (e.g., 4-20 mA, 0-10V, dry contact, and thermocouples and thermistors). The data collecting module NEVOTON DCM-5.1.1-Z can manage with 5 sensors at the same time, as well as it is able to control one external device (has one switching relay). List of the types of respondents sensors corresponds to the modern equipment of industrial automation: 1. Platinum thermistor 50, 100, 500, 1000. Accuracy: 0,1°С, measurement error: above 0,1% 2. Copper thermistor 50, 100, 500, 1000. Accuracy: 0,1°С, measurement error: above 0,1% 3. Thermocouples: R,S,B,J,T,E,K,N,A,L,M types. Accuracy: 1°С, measurement error: above 0,1% 4. DC current signal 0..5 mA. Measurement error: above 0,1% 5. DC current signal 0..20 mA. Measurement error: above 0,1% 6. DC current signal 4..20 mA. Measurement error: above 0,1% 7. DC voltage signal 0..10 V. Measurement error: above 0,1% 8. DC voltage signal -50..+50 mV Measurement error: above 0,1% 9. DC voltage signal 0..1 V Measurement error: above 0,1% 10. Dry contact 11. Flap position sensor 0..900 Ohm 12. Flap position sensor 0..2000 Ohm
Long descriptionNEVOTON DCM-5.1.1-Z - is a Z-Wave device which is intended for industrial and household sensors with electrical outputs of different types (e.g., 4-20 mA, 0-10V, dry contact, and thermocouples and thermistors). The data collecting module NEVOTON DCM-5.1.1-Z can manage with 5 sensors at the same time, as well as it is able to control one external device (has one switching relay). List of the types of respondents sensors corresponds to the modern equipment of industrial automation: 1. Platinum thermistor 50, 100, 500, 1000. Accuracy: 0,1°С, measurement error: above 0,1% 2. Copper thermistor 50, 100, 500, 1000. Accuracy: 0,1°С, measurement error: above 0,1% 3. Thermocouples: R,S,B,J,T,E,K,N,A,L,M types. Accuracy: 1°С, measurement error: above 0,1% 4. DC current signal 0..5 mA. Measurement error: above 0,1% 5. DC current signal 0..20 mA. Measurement error: above 0,1% 6. DC current signal 4..20 mA. Measurement error: above 0,1% 7. DC voltage signal 0..10 V. Measurement error: above 0,1% 8. DC voltage signal -50..+50 mV Measurement error: above 0,1% 9. DC voltage signal 0..1 V Measurement error: above 0,1% 10. Dry contact 11. Flap position sensor 0..900 Ohm 12. Flap position sensor 0..2000 Ohm Short descriptionNEVOTON DCM-5.1.1-Z - is a Z-Wave Input-Output module 5th channel which is intended for industrial and household sensors with electrical outputs of different types (e.g., 4-20 mA, 0-10V, dry contact, and thermocouples and thermistors).