RGBW-Control is a universal, Z-Wave Plus™ compatible RGB/RGBW controller. The device uses PWM output signal, allowing it to control LED, RGB, RGBW strips, halogen lights and other resistive loads. It can also measure active power and energy consumed by the load. Controlled devices may be powered by 12 or 24V DC. Inputs support momentary/toggle switches and 0-10V analog sensors, like temperature sensors, humidity sensors, light sensors etc.
Want to buy adds it to your wish list and follows Nice for updates. I own it adds it to your collection.
✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Nice shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
RGBW-Control is a universal, Z-Wave Plus™ compatible RGB/RGBW controller. The device uses PWM output signal, allowing it to control LED, RGB, RGBW strips, halogen lights and other resistive loads. It can also measure active power and energy consumed by the load. Controlled devices may be powered by 12 or 24V DC. Inputs support momentary/toggle switches and 0-10V analog sensors, like temperature sensors, humidity sensors, light sensors etc.
Hardware platform
ZM5101
Short description
RGBW-Control is a universal, Z-Wave Plus™ compatible RGB/RGBW controller. The device uses PWM output signal, allowing it to control LED, RGB, RGBW strips, halogen lights and other resistive loads
Product identifier
FGRGBW-442
Countries / regions
European Union
Supports smart start
Yes
Certification number
ZC10-22047077
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_SWITCH_COLOR_V3
Supported multilevel sensors
Multilevel Sensor Type Voltage
Supported notification types
Notification Type Event / State Power Management
Value white association groups
Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 2
Supported / controlled meter types
Meter Type Rate Type Description Electric meter
From to description 0 0 device remains switched off 1 1 device restores the state from before the power failure 23 input 4 operating mode this parameter allows to choose mode of 4th input (in4). change it depending on connected device. 1 1 0 4 2 from to description 1 1 analog input with internal pull up (sensor multilevel) 2 2 momentary switch (central scene) 3 3 toggle switch: switch state on every input change (central scene) 4 4 toggle switch: contact closed – on, contact opened – off (central scene) 0 0 analog input without internal pull up (sensor multilevel) 31 alarm configuration 2nd slot this parameter determines to which alarm frames and how the device should react. the parameters consist of 4 bytes, three most significant bytes are set according to the official z wave protocol specification. x – channels summarized: 1/2/3/4 channel are equal to values 1/2/4/8. y – sequence number: 1 10 (parameter 157). 1 4 0 2147483647 100597760 from to description 0 255 [lsb] – action 256 65535 event/state parameters 65536 16777215 notification status 16777216 2147483647 [msb] – notification type 63 analog inputs reports and output change on input change this parameter defines minimal change (from the last reported) of analog input voltage that results in sending new report and change in the output value. parameter is relevant only for analog inputs (parameter 20, 21, 22 or 23 set to 0 or 1). 1 2 0 100 5 from to description 0 0 reporting on change disabled 1 100 0.1 10 v, 0.1 v step 65 energy reports on change this parameter determines the minimum change in consumed energy that will result in sending new energy report to the main controller. energy reports are sent no often than every 30 seconds. 1 2 0 500 10 from to description 0 0 reports are disabled 1 500 (0.01 5 k wh) change in energy 150 inputs led colour control mode this parameter determines how connected switches control led strips. 1 1 0 1 0 from to description 0 0 rgbw mode (every input controls output with the same number, in1‑out1, in2‑out2, in3‑out3, in4‑out4) 1 1 hsb and white mode (inputs works in hsb color model, in1‑h (hue), in2‑s (saturation), in3‑b (brightness), in4‑white (out4) 151 local control transition time this parameter determines time of smooth transition between 0% and 100% when controlling with connected switches. 1 2 0 254 3 from to description 0 0 instantly 1 127 1 s 127 s, 1 s step 128 254 1 min 127 min, 1 min step 152 remote control transition time this parameter determines time needed to change the state between current and target values when controlling via z wave network. 1 2 0 254 0 from to description 0 0 instantly 1 127 1 s 127 s, 1 s step 128 254 1 min 127 min, 1 min step 154 on frame value for single click this parameter defines value sent to devices in association groups. the parameters consist of 4 bytes, each byte reserved for separate channel, from least significant (in1) to most significant (in4). applicable for basic set and switch multilevel set commands. 1 4 0 2147483647 2147483647 from to description 0 99 value for every byte (msb to lsb) 255 255 value for every byte (msb to lsb) 157 start programmed sequence setting this parameter will start programmed sequence with selected number. user can define own sequences via controller. while the sequence is active, the menu is unavailable. 1 1 0 10 0 from to description 0 0 sequence inactive 1 5 user defined sequence 6 6 fireplace sequence 7 7 storm sequence 8 8 rainbow sequence 9 9 aurora sequence 10 10 police (red white blue) sequence 155 off frame value for single click this parameter defines value sent to devices in association groups. the parameters consist of 4 bytes, each byte reserved for separate channel, from least significant (in1) to most significant (in4). applicable for basic set and switch multilevel set commands. 1 4 0 2147483647 0 from to description 0 99 value for every byte (msb to lsb) 255 255 value for every byte (msb to lsb) 156 on frame value for double click this parameter defines value sent to devices in association groups. the parameters consist of 4 bytes, each byte reserved for separate channel, from least significant (in1) to most significant (in4). applicable for basic set and switch multilevel set commands. 1 4 0 2147483647 1667457891 from to description 0 99 value for every byte (msb to lsb) 255 255 value for every byte (msb to lsb) texts