✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Nice shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Smoke-Control is a universal, optical Z-Wave™ smoke detector. A fire alarm is signaled by sound, visual indicator blinking, and sending Z-Wave alarm and control commands. The optical sensor detects smoke at an early stage of fire, often before flames appear and the temperature rises significantly. Moreover, the device has a built-in temperature sensor, a programmable indicator of exceeding the set temperature level. Smoke-Control is designed to be placed on a wall or ceiling. Visual indicator signals fire operating mode and are used to see if the device is within the Z-Wave network. Smoke-Control is designed to operate in confined spaces under normal conditions (lacking smoke, dust, condensed water vapor).
Want to buy adds it to your wish list and follows Nice for updates. I own it adds it to your collection.
Smoke-Control is a universal, optical Z-Wave™ smoke detector. A fire alarm is signaled by sound, visual indicator blinking, and sending Z-Wave alarm and control commands. The optical sensor detects smoke at an early stage of fire, often before flames appear and the temperature rises significantly. Moreover, the device has a built-in temperature sensor, a programmable indicator of exceeding the set temperature level. Smoke-Control is designed to be placed on a wall or ceiling. Visual indicator signals fire operating mode and are used to see if the device is within the Z-Wave network. Smoke-Control is designed to operate in confined spaces under normal conditions (lacking smoke, dust, condensed water vapor).
Hardware platform
ZM5202
Short description
Smoke-Control is a universal, optical Z-Wave™ smoke detector. A fire alarm is signaled by sound, visual indicator blinking, and sending Z-Wave alarm and control command
Association groups
Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 2
Product identifier
FGSD-002
Countries / regions
European Union
Certification number
ZC10-22047080
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_SENSOR_ALARM
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported multilevel sensors
Multilevel Sensor Type Air temperature
Supported notification types
Notification Type Event / State Smoke Alarm
From to description 1 3 smoke control sensitivity 2 z wave notifications status this parameter allows to activate excess temperature and/or casing opening notifications sent to the main controller. 1 1 0 2 0 from to description 0 2 z wave notifications status 3 visual indicator notifications status this parameter allows to activate visual indications but does not apply to major alarms, such as fire, trouble and low battery alarm. 1 1 0 7 0 from to description 0 7 visual indicator notifications status 4 sound notifications status this parameter allows to activate sound signals but does not apply to major alarms, such as fire, trouble and low battery alarm. 1 1 0 7 0 from to description 0 7 sound notifications status 5 configuration of control frames in basic command class this parameter defines which frames will be sent in the 2 nd association group (smoke alarm). the values of basic on and basic off frames may be defined as described in further parameters. 1 1 0 2 0 from to description 0 2 configuration of control frames in basic command class 6 basic on frame value basic on frame is sent in case of smoke presence detection and fire alarm triggering. its value is defined by the parameter. 1 2 0 255 255 from to description 0 255 basic on frame value 7 basic off frame value basic off frame is sent in case of fire alarm cancellation. its value is defined by the parameter 1 2 0 255 0 from to description 0 255 basic off frame value 8 alarm broadcast a value other than 0 means that alarms are being sent in broadcast mode, i.e. to all devices within smoke control’s range. 1 1 0 3 0 from to description 0 3 alarm broadcast 10 temperature report interval time interval between consecutive temperature reports. report is sent when new temperature value is different from the one previously reported according to the set hysteresis (parameter 21). temperature reports can be also sent as a result of polling. 1 2 0 8640 1 from to description 0 8640 temperature report interval 11 temperature report hysteresis the temperature report will only be sent if there is a difference in temperature value from the previous value reported, defined in this parameter (hysteresis). temperature reports can be also sent as a result of polling. 1 1 1 100 10 from to description 1 100 temperature report hysteresis texts