✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Zooz shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Community photos
Photos from members
No member photos yet.
Reviews
What members say
Sign in to rate S2 ON/OFF SWITCH 700 and share a photo.
No reviews yet.
Community
Be the first to start a thread about S2 ON/OFF SWITCH 700
HIGHLIGHTS: - Manual or Z-Wave on/off control with instant status updates - NEW: 700 series Z-Wave chip for better range and faster control - Simple Direct 3-Way: connect with existing on/off switches in 3-way, 4-way, and 5-way set-ups, no add-on needed - Scene control: trigger actions with multi-tap (select hubs only) - Smart bulb mode: disable relay and control the light via Z-Wave - Remembers and restores on/off status after power failure - Adjustable LED indicator in 4 colors and 3 brightness levels - Works with LED and incandescent bulbs (don’t use with tubes) SPECS: - Model Number: ZEN76 - Z-Wave Signal Frequency: 908.42 MHz - Power: 120 VAC, 60 Hz - Maximum Load: 8 A, 150 W LED/CFL, 600 W incandescent, 960 W resistive (DON’T use with tube lights, fans, or receptacles) - Range: Up to 500 feet line of sight - Operating Temperature: 32-104° F (0-40° C) - Installation and Use: Indoor only
Want to buy adds it to your wish list and follows Zooz for updates. I own it adds it to your collection.
HIGHLIGHTS: - Manual or Z-Wave on/off control with instant status updates - NEW: 700 series Z-Wave chip for better range and faster control - Simple Direct 3-Way: connect with existing on/off switches in 3-way, 4-way, and 5-way set-ups, no add-on needed - Scene control: trigger actions with multi-tap (select hubs only) - Smart bulb mode: disable relay and control the light via Z-Wave - Remembers and restores on/off status after power failure - Adjustable LED indicator in 4 colors and 3 brightness levels - Works with LED and incandescent bulbs (don’t use with tubes) SPECS: - Model Number: ZEN76 - Z-Wave Signal Frequency: 908.42 MHz - Power: 120 VAC, 60 Hz - Maximum Load: 8 A, 150 W LED/CFL, 600 W incandescent, 960 W resistive (DON’T use with tube lights, fans, or receptacles) - Range: Up to 500 feet line of sight - Operating Temperature: 32-104° F (0-40° C) - Installation and Use: Indoor only
Hardware platform
ZGM130
Short description
700 Series Z-Wave Plus S2 On/Off Switch with Simple Direct 3-Way and 4-Way Patented Solution.
Product identifier
ZEN76
Countries / regions
United States of America
Supports smart start
Yes
Certification number
ZC12-21020182
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
Value incandescent led switch load capacity current value 8 switch load capacity watts value 600 color value white z wave scene type value central scene firmware updatable value updatable by consumer by rf neutral wire required association groups
Group Number Maximum Nodes Supported End Point ID Group Name Description 2
From to description 0 0 led indicator is on when switch is off, led indicator is off when switch is on (default) 1 1 led indicator is on when switch is on, led indicator is off when switch is of 2 2 led indicator is always off 3 3 led indicator is always on 3 auto turn off timer use this parameter to enable or disable the auto turn off timer function (the time after which you want the switch to automatically turn off once it has been turned on). 2 4 0 65535 0 from to description 0 0 timer disabled 1 65535 minutes 5 auto turn on timer use this parameter to enable or disable the auto turn on timer function (the time after which you want the switch to automatically turn on once it has been turned off). 2 4 0 65535 0 from to description 0 0 timer disabled 1 65535 minutes 10 enable or disable scene enable or disable scene control functionality for quick double tap triggers. 2 1 0 1 0 from to description 0 0 scene control disabled 1 1 scene control enabled 8 on off status after power failure set the on off status for the switch after power failure. 2 1 0 2 2 from to description 2 2 remembers and restores on/off status after power failure (default) 0 0 forced to off (regardless of state prior to power outage) 1 1 forced to on (regardless of state prior to power outage) 1 on/off paddle orientation choose if you want the upper paddle to turn the light on or turn the light off when tapped. 2 1 0 2 0 from to description 0 0 upper paddle turns the light on, lower paddle turns it off (default) 1 1 upper paddle turns the light off, lower paddle turns it on 2 2 any paddle turns light on/off. texts