✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Aeotec shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Companion app is actively updated
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Aeotec Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch. The Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
Want to buy adds it to your wish list and follows Aeotec for updates. I own it adds it to your collection.
Aeotec Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status. It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Nano Switch. The Nano Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
Hardware platform
ZM5101
Short description
Aeotec Nano Switch is a Z-Wave Smart Switch specifically used to enable Z-Wave command and control (on/off) of any wall switches also provides energy metering.
Product identifier
ZW116-F
Countries / regions
India
Certification number
ZC10-18106251
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 4
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_SCENE_ACTUATOR_CONF
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported notification types
Notification Type Event / State Heat Alarm
Supported / controlled meter types
Meter Type Rate Type Description Electric meter
Value scene firmware updatable value updatable by consumer by rf supported meter type value electric energy supported notification types value heat alarm power management electric load type value incandescent fluorescent mlv (magnetic) elv (electronic) led dimmable led inductive (e.g. motor) switch type value toggle association groups
Group Number Maximum Nodes Supported End Point ID Description 1
From to description 0 0 disable 1 1 enable 84 set the on/off time of the led when it is in night light mode. set the on/off time of the led when it is in night light mode. 0 1 0 0 301991936 from to description 0 60 the minute time of off 256 316 the hour time of off 65536 65596 the minute time of on 16777216 16777276 the hour time of on 86 set appointment 1 set the on time of output load. 0 4 0 0 8327680 from to description 0 60 the minute value of on time 256 316 the hour value of on time 65536 65543 the day value (mon to sun) 16777215 16777215 disable the setting. 16777216 16777216 enable the setting. 83 configure the state of led when it is in 3 modes configure the state of led when it is in 3 modes (energy mode, momentary indicate mode, night light mode) 0 1 0 0 0 from to description 0 0 energy mode. the led will follow the status (on/off). 1 1 momentary indicate mode. when the state of switch’s load changed, the led will follow the status (on/off) of its load, but the led will turn off after 5 seconds if there is no any switch action. 2 2 night light mode. the led will remain on state. 100 set parameter 101 103 to default value. set parameter 101 103 to default value. 0 1 0 0 0 from to description 0 0 reset the parameter 101 103 101 to set which reports need to be sent in report group 1. to set which reports need to be sent in report group 1. 0 4 0 0 0 from to description 1 1 send meter report of energy (k wh) 2 2 send meter report of wattage (w) 4 4 send meter report of voltage (v) 8 8 send meter report of current (a) 92 set the threshold value of wattage. threshold change in wattage (in terms of percentage) to induce an automatic report. 0 1 0 0 5 from to description 0 100 the thershold value range is 0 to 100 103 to set which reports need to be sent in report group 3. to set which reports need to be sent in report group 3. 0 1 0 0 0 from to description 1 1 send meter report of voltage (v) 2 2 send meter report of current (a) 4 4 send meter report of wattage (w) 8 8 send meter report of energy (k wh) 122 set the control destination for external switch set the control destination for external switch 0 1 0 0 3 from to description 1 1 control the output loads of itself. 2 2 control the other nodes 3 3 control the output loads of itself and other nodes. 252 lock/unlock configuration parameters lock/unlock configuration parameters. 0 1 0 0 0 from to description 0 0 unlock 1 1 lock 255 reset the nano switch reset the nano switch to factory default. 0 4 0 0 0 from to description 0 0 reset all configuration parameters to factory default setting 1431655765 1431655765 reset to factory default setting and removed from the z wave network 3 current overload protection. output load will be turned off automatically after 30 seconds and if the current overrun 15.5 a. 0 1 0 0 1 from to description 0 0 disable 1 1 enable 121 configure the external switch mode for s2. configure the external switch mode for s2. 0 1 0 0 0 from to description 0 0 enter automatic identification mode 1 1 2 state switch mode 2 2 3 way switch mode 3 3 momentary push button mode 80 to set which notification would be sent to the associated devices (group 1) to set which notification would be sent to the associated devices (group 1) when the state of nano dimmer’s load is changed. 0 1 0 0 3 from to description 0 0 send nothing 1 1 send hail cc 2 2 send basic report cc 3 3 send hail cc when using the manual switch to change the load state. 82 to set which notification would be sent to the associated nodes in association group 4 to set which notification would be sent to the associated nodes in association group 4 when using the external switch 2 to switch the loads. 0 1 0 0 1 from to description 0 0 send nothing 1 1 send basic set cc 87 set appointment 2 set the off time of output load. 0 4 0 0 8327680 from to description 0 60 the minute value of on time 256 316 the hour value of on time 65536 65543 the day value (mon to sun) 16777215 16777215 disable the setting. 16777216 16777216 enable the setting. 90 enables/disables parameter 91 and 92 below: enables/disables the function of parameter 91 and 92. 0 1 0 0 0 from to description 0 0 disable 1 1 enable 110 set parameter 111 113 to default value. set parameter 111 113 to default value. 0 1 0 0 0 from to description 0 0 reset the parameter 111 113 120 configure the external switch mode for s1. configure the external switch mode for s1. 0 1 0 0 0 from to description 0 0 enter automatic identification mode 1 1 2 state switch mode 2 2 3 way switch mode 3 3 momentary push button mode 81 to set which notification would be sent to the associated nodes in association group 3 to set which notification would be sent to the associated nodes in association group 3 when using the external switch 1 to switch the loads. 0 1 0 0 1 from to description 0 0 send nothing 1 1 send basic set cc 91 set the threshold value of wattage. threshold change in wattage (in terms of wattage) to induce an automatic report. 0 2 0 0 25 from to description 0 60000 the thershold value range is 0 to 60000 102 to set which reports need to be sent in report group 2. to set which reports need to be sent in report group 2. 0 1 0 0 0 from to description 1 1 send meter report of energy (k wh) 2 2 send meter report of wattage (w) 4 4 send meter report of voltage (v) 8 8 send meter report of current (a) 111 set the interval of automatic report for report group 1. set the interval of automatic report for report group 1. 0 4 0 0 10 from to description 1 2147483647 the range of interval time is 1 to 2147483647. 112 set the interval of automatic report for report group 2. set the interval of automatic report for report group 2. 0 4 0 0 600 from to description 1 2147483647 the range of interval time is 1 to 2147483647. 113 set the interval of automatic report for report group 2. set the interval of automatic report for report group 3. 0 4 0 0 600 from to description 1 2147483647 the range of interval time is 1 to 2147483647. texts