Long descriptionQuad.Switch CT4R is a miniature micromodule to operate in AC mains. On AC mains it operates with the common neutral load. It has the following features • Four Relay switches enable ON/OFF control of Regular loads. • Typical Regular relay loads (4R) are light sources (incandescent bulbs, CFL, LED lamps… etc), heaters, fans, air-conditioners, fridges, door openers, and other utility appliances. • The Quad switch CT4R also operates as a repeater within the Z-Wave network it is associated with. Value updatable by professional/technician loads controlled value 4 neutral wire required switch load capacity current value 8 a switch load capacity volt ampere value 100 vac 240 vac switch load capacity watts value 2000 w electric load type value incandescent fluorescent led inductive (e.g. motor) association groupsGroup Number Maximum Nodes Supported End Point ID Description 1 From to description 0 1 0: memory, 1: switch s2 1 240 1 minute to 240 minutes (4 hours) 6 auto off for load l2 this parameter decides the on time duration for load2 (l2). it ranges from 1 minute to 240 minutes i.e. 4 hours. auto off counting starts as soon as l2 is turned on either via s2 or gui. once duration expires the l2 turned off automatically. setting this value to 0 (zero) will disable auto off functionality. 0 1 0 0 0 from to description 1 240 1 minute to 240 minutes (4 hours) 2 power on state for load2 (l2) this parameter decides the power on state (when the module is powered on) of load2 (l2). this parameter provides two options either power on to memory (previous state as it was before power off) or present switch position. 0 1 0 0 0 from to description 0 1 0: memory, 1: switch s2 8 auto off for load l4 this parameter decides the on time duration for load4 (l4). it ranges from 1 minute to 240 minutes i.e. 4 hours. auto off counting starts as soon as l4 is turned on either via s4 or gui. once duration expires the l4 turned off automatically. setting this value to 0 (zero) will disable auto off functionality. 0 1 0 0 0 from to description 1 240 1 minute to 240 minutes (4 hours) 9 combine relays/endpoints this parameter is designed to combine two or more relays to handle higher wattage load current. 1: l1 only operates with s1 and gui master. 2: l1 & l2 only operates with s1 and gui master. 3: l1, l2, & l3 only operates with s1 and gui master. 4: l1, l2, l3, & l4 only operates with s1 and gui master. default: 1 l1 only operates with s1 and gui master 0 1 0 0 1 from to description 1 4 1,2,3,4 17 local switch s3 enable/disable this parameter makes local switch s3 either enable or disable. by default, this is set to 1 (enable s3). 0 1 0 0 1 from to description 0 1 0: disable, 1: enable 10 switch s1 behavior this parameter defines the behaviour of switch s1. if set to 0, it behaves like a regular switch (i.e. putting a switch to on position will turn on l1 and putting to off position will turn off l1) and if set to 1, it behaves like a toggle switch (i.e. putting the switch to either on or off position makes l1 toggle). default: 0 regular switches (i.e. on to on and off to off) 0 1 0 0 0 from to description 0 1 0: regular switch (i.e. on to on and off to off), 1: toggle switch (on to toggle and off to toggle) 11 switch s2 behaviour this parameter defines the behaviour of switch s2. if set to 0, it behaves like the regular switch (i.e. putting the switch to on position will turn on l2 and putting to off position will turn off l2) and if set to 1, it behaves like a toggle switch (i.e. putting the switch to either on or off position makes l2 toggle). default: 0 regular switches (i.e. on to on and off to off) 0 1 0 0 0 from to description 0 1 0: regular switch (i.e. on to on and off to off), 1: toggle switch (on to toggle and off to toggle) 3 power on state for load3 (l3) this parameter decides the power on state (when the module is powered on) of load3 (l3). this parameter provides two options either power on to memory (previous state as it was before power off) or present switch position. 0 1 0 0 0 from to description 0 1 0: memory, 1: switch s3 4 power on state for load4 (l4) this parameter decides the power on state (when the module is powered on) of load4 (l4). this parameter provides two options either power on to memory (previous state as it was before power off) or present switch position. upcoming parameter 05, 06, 07, 08 comes in conflict with parameter 09 when set to value 02, 03, 04. parameter 09 designed to combine multiple relays to handle a higher wattage load. the user must set this parameter to 0, before enabling relay combination via parameter 09 to avoid a hazardous situation. 0 1 0 0 0 from to description 0 1 0: memory, 1: switch s4 1 power on state for load1 (l1) this parameter decides the power on state (when the module is powered on) of load1 (l1). this parameter provides two options either power on to memory (previous state as it was before power off) or present switch position. 0 1 0 0 0 from to description 0 1 0: memory, 1: switch s1 5 auto off for load l1 this parameter decides the on time duration for load1 (l1). it ranges from 1 minute to 240 minutes i.e. 4 hours. auto off counting starts as soon as l1 is turned on either via s1 or gui. once duration expires the l1 turned off automatically. setting this value to 0 (zero) will disable auto off functionality. 0 1 0 0 0 from to description 1 240 1 minute to 240 minutes (4 hours) textsID Description Value 5