Long descriptionThe remotely operated FIBARO Smart Module are designed to turn electrical devices or circuits on and off. Smart Module allows to control one device or circuit. The compact size of the device allows for the product to be installed in the housings of other devices. The devices can be controlled either via the Z-Wave™ network or with buttons connected directly to them. From to description 0 0 relays remain switched off after restoring power 1 1 restore remembered state of relays after restoring power 2 2 restore remembered state of relays after restoring power, but for toggle switches (parameter 20/21 set to 1) set the same state as the current state of the switches 24 inputs orientation this parameter allows reversing operation of s1 and s2 inputs without changing the wiring. use in case of incorrect wiring. 1 1 0 1 0 from to description 0 0 default (s1 1st channel, s2 2nd channel) 1 1 reversed (s1 2nd channel, s2 1st channel) 31 alarm configuration 2nd slot this parameter determines to which alarm frames and how the device should react. the parameters consist of 4 bytes, three most significant bytes are set according to the official z wave protocol specification. default value [0x05, 0x ff, 0x00, 0x00] (water alarm, any notification, no action). the 4 bytes must be converted to a single decimal value to be entered in the gateway sending the configuration parameter value. example: event: home security (0x07) status: motion detected (0x08) parameter: none (0x00) action: turn on (0x01) = 0x07080001 which is 117964801 decimal to be entered in the gateway. 1 4 0 2147483647 100597769 from to description 0 255 [lsb] – action 256 65535 event/state parameters 65536 16777215 notification status 16777216 2147483647 [msb] – notification type 150 first channel – operating mode this parameter allows to choose operating mode for channel controlled with q/q1 output. for timed modes (value 1, 2 or 3), time is set with parameter 154 and reaction to input change is set with parameter 152. 1 1 0 3 0 from to description 0 0 standard operation 1 1 delayed off 2 2 auto off 3 3 flashing 152 first channel – reaction to input change in delayed/ auto off modes this parameter determines how the device reacts when changing state of s1 input in timed modes for first channel. 1 1 0 2 0 from to description 2 2 reset timer, start counting time from the beginning 1 1 no reaction, mode runs until it ends 0 0 cancel mode and set default state 154 first channel – time parameter for delayed/auto off and flashing modes this parameter allows to set time parameter used in timed modes for first channel. for delayed/ auto off modes it determines duration, for flashing mode it determines cycle period. 1 2 0 32000 5 from to description 0 0 0.1 seconds 1 32000 0.1 3200 seconds, 0.1s step 156 s1 input – switch on value sent to 2nd association group this parameter defines value sent with switch on command to devices in 2nd association group when using s1 input. 1 2 0 255 255 from to description 0 0 turn off 1 99 turn on and set level 255 255 turn on with last level 157 s1 input – switch off value sent to 2nd association group this parameter defines value sent with switch off command to devices in 2nd association group when using s1 input. 1 2 0 255 0 from to description 0 0 turn off 1 99 turn on and set level 255 255 turn on with last level 158 s1 input – double click value sent to 2nd association group this parameter defines value sent with double click command to devices in 2nd association group when using s1 input. 1 2 0 255 99 from to description 255 255 turn on with last level 0 0 turn off 1 99 turn on and set level 162 q/q1 output type this parameter determines type of q/q1 output. 1 1 0 1 0 from to description 1 1 normally closed (relay contacts closed turned off, opened when turned on) 0 0 normally open (relay contacts opened turned off, closed when turned on) textsID Description Value 8