✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if FIBARO shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Community photos
Photos from members
No member photos yet.
Reviews
What members say
Sign in to rate Wall Roller Shutter and share a photo.
No reviews yet.
Community
Be the first to start a thread about Wall Roller Shutter
Threads post into the FIBARO community forum.
Sign in to start a thread in the FIBARO community.
Edit history
Loading edit history…
Certified
FIBARO Walli Roller Shutter is a smart wall switch designed to control motors of roller blinds, awnings, venetian blinds and other single phase, AC powered devices via Z-Wave network. It measures active power and energy consumed by the controlled load. You can install it with provided cover plate or other compatible. Main features of FIBARO Walli Roller Shutter: - Can be used with: o Roller blinds, o Venetian blinds, o Awnings, o Blind motors with electronic or mechanical limit switches. - Can be used with provided cover plate or one of the following: o GIRA – System 55 (Standard 55, E2, Event, Event Clear), o Legrand – Céliane, o Schneider – Odace. - Active power and energy consumption metering. - Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 Authenticated with PRNG-based encryption. - Works as Z-Wave signal repeater (all non-battery operated devices within the network will act as repeaters to increase reliability of the network). - May be used with all devices certified with the Z-Wave Plus certificate and should be compatible with such devices produced by other manufacturers.
Want to buy adds it to your wish list and follows FIBARO for updates. I own it adds it to your collection.
FIBARO Walli Roller Shutter is a smart wall switch designed to control motors of roller blinds, awnings, venetian blinds and other single phase, AC powered devices via Z-Wave network. It measures active power and energy consumed by the controlled load. You can install it with provided cover plate or other compatible. Main features of FIBARO Walli Roller Shutter: - Can be used with: o Roller blinds, o Venetian blinds, o Awnings, o Blind motors with electronic or mechanical limit switches. - Can be used with provided cover plate or one of the following: o GIRA – System 55 (Standard 55, E2, Event, Event Clear), o Legrand – Céliane, o Schneider – Odace. - Active power and energy consumption metering. - Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 Authenticated with PRNG-based encryption. - Works as Z-Wave signal repeater (all non-battery operated devices within the network will act as repeaters to increase reliability of the network). - May be used with all devices certified with the Z-Wave Plus certificate and should be compatible with such devices produced by other manufacturers.
Hardware platform
ZM5101
Short description
FIBARO Walli Roller Shutter is a smart wall switch designed to control motors of roller blinds, awnings, venetian blinds and other single phase, AC powered devices via Z-Wave network.
Product identifier
FGWREU-111
Countries / regions
European Union
Supports smart start
Yes
Certification number
ZC10-19056517
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 24
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_SWITCH_MULTILEVEL_V4
Supported notification types
Notification Type Event / State Power Management
Supported / controlled meter types
Meter Type Rate Type Description Electric meter
Value white electric load type value inductive (e.g. motor) loads controlled value 2 supported meter type value electric energy supported notification types value power management system switch load capacity current value 4 a for motors with compensated power factor (inductive loads); 13 a for resistive loads switch type value push button association groups
Group Number Maximum Nodes Supported End Point ID Description 1
From to description 0 0 default (1st button up, 2nd button down) 1 1 reversed (1st button down, 2nd button up) 25 outputs orientation this parameter allows reversing the operation of q1 and q2 without changing the wiring (e.g. in case of invalid motor connection). 0 1 0 0 0 from to description 0 0 (q1 – up, q2 – down)led disabled 1 1 reversed (q1 – down, q2 – up) 31 alarm configuration 2nd slot this parameter determines to which alarm frames and how the device should react. the parameters consist of 4 bytes, three most significant bytes are set according to the official z wave protocol specification. 0 4 0 0 0 from to description 1 1 [msb] – notification type 2 2 notification value 3 3 event/state parameters 4 4 [lsb] – action 41 second button – scenes sent this parameter determines which actions result in sending scene ids assigned to them. values can be combined (e.g. 1+2=3 means that scenes for single and double click are sent). enabling scenes for triple click disables entering the device in learn mode by triple clicking. 0 1 0 0 0 from to description 1 1 key pressed 1 time 2 2 key pressed 2 time 4 4 key pressed 3 time 8 8 key hold down and key released 60 power reports – include self consumption this parameter determines whether the power measurements should include power consumed by the device itself. 0 1 0 0 0 from to description 0 0 self consumption not included 1 1 self consumption included 11 led frame – colour when moving this parameter defines the led colour when the motor is running. 0 1 0 0 1 from to description 0 0 led disabled 1 1 white 2 2 red 3 3 green 4 4 blue 5 5 yellow 6 6 cyan 7 7 magenta 65 energy reports – on change this parameter defines minimal change (from the last reported) in measured energy that results in sending new report. 0 2 0 0 10 from to description 0 0 reporting on change disabled 1 500 (0.01 5k wh, 0.01k wh step) – minimal change 150 force calibration by setting this parameter to 2 the device enters the calibration mode. the parameter relevant only if the device is set to work in positioning mode (parameter 151 set to 1 or 2). 0 1 0 0 0 from to description 0 0 device is not calibratedv 1 1 device is calibrated 2 2 force device calibration 151 operating mode this parameter allows adjusting operation according to the connected device. 0 1 0 0 1 from to description 1 1 roller blind (with positioning) 2 2 venetian blind (with positioning) 5 5 roller blind with built in driver 6 6 roller blind with built in driver (impulse) 152 venetian blind – time of full turn of the slats for venetian blinds (parameter 151 set to 2) the parameter determines time of full turn cycle of the slats. the parameter is irrelevant for other modes. 0 4 0 0 150 from to description 0 65535 (0 655.35s, every 0.01s) time of turn 153 set slats back to previous position for venetian blinds (parameter 151 set to 2) the parameter determines slats positioning in various situations. the parameter is irrelevant for other modes. 0 1 0 0 1 from to description 0 0 slats return to previously set position only in case of the main controller operation 1 1 slats return to previously set position in case of the main controller operation, momentary switch operation, or when the limit switch is reached 2 2 slats return to previously set position in case of the main controller operation, momentary switch operation, when the limit switch is reached or after receiving the switch multilevel stop control frame 154 delay motor stop after reaching end switch the parameter determines the time after which the motor will be stopped after end switch contacts are closed. 0 2 0 0 10 from to description 1 255 (0.1s 25.5 seconds) 155 motor operation detection power threshold interpreted as reaching a limit switch. 0 2 0 0 10 from to description 0 0 no detection 1 255 (1 255 w) report interval 156 time of up movement this parameter determines the time needed for roller blinds to reach the top. for modes with positioning value is set automatically during calibration, otherwise, it must be set manually. 0 4 0 0 6000 from to description 1 65535 (0.01 655.35 seconds) 157 time of down movement this parameter determines the time needed for roller blinds to reach the bottom. for modes with positioning value is set automatically during calibration, otherwise, it must be set manually. 0 4 0 0 6000 from to description 1 65535 (0.01 655.35 seconds) texts