Built with premium components for better performance, these motion sensors provide instant and reliable performance as part of your security system. Ness is a leading developer of low power, highly reliable wireless solutions, including a wide range of intelligent wireless security, sensing and home automation devices.
Want to buy adds it to your wish list and follows Ness for updates. I own it adds it to your collection.
✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Ness shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Community photos
Photos from members
No member photos yet.
Reviews
What members say
Sign in to rate Ness Z-Wave LUX PIR Sensor and share a photo.
No reviews yet.
Community
Be the first to start a thread about Ness Z-Wave LUX PIR Sensor
Built with premium components for better performance, these motion sensors provide instant and reliable performance as part of your security system. Ness is a leading developer of low power, highly reliable wireless solutions, including a wide range of intelligent wireless security, sensing and home automation devices.
Hardware platform
ZGM130
Short description
The LUX Z-Wave Radio PIR allows you to improve the safety and security of your home and family easily and effectively.
Product identifier
ZA-117001
Countries / regions
Australia
Supports smart start
Yes
Certification number
ZC12-21060233
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Read-only Flag Advanced Size Min Value Max Value Default Value Parameter Values 6
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
Supported multilevel sensors
Multilevel Sensor Type Air temperature
Supported notification types
Notification Type Event / State Home Security
Value white battery type value cr123 a+ battery quantity value 2 association groups
Group Number Maximum Nodes Supported End Point ID Group Name Description 1
From to description 0 0 disable luminance value scanning, no report 1 60 lux luminance value 2 motion alarm retrigger modes this option will select how the motion alarm retrigger duration timer (cpn#1) to be reset. range: 0~1. value = 0, in this mode, the motion alarm retrigger duration timer (cpn#1) will be reset to zero once the motion event is detected. hence, the motion alarm retrigger duration timer will start recounting which extends the retrigger duration. this mode will extend the battery life and reduce unnecessary motion alarm reports (default). value = 1, in this mode, the motion alarm retrigger duration timer (cpn#1) would not be reset once the motion event has detected. the motion alarm reports will be enabled to send once the motion alarm retrigger duration timer has expired. in this mode, it will report the motion alarm event with greater fidelity. this setting might be used where the device will be used for automation tasks. 2 yes yes 1 0 1 0 from to description 0 0 motion alarm retrigger duration timer (cpn#1) will be reset to zero once the motion event is detected 1 1 motion alarm retrigger duration timer (cpn#1) would not be reset once the motion event has detected 9 temperature scale setting option to select the temperature scale type reported in celsius or fahrenheit. range: 0~1. value = 0 celsius (c): value = 1 fahrenheit (f). 2 yes 1 0 1 0 from to description 0 0 celsius 1 1 fahrenheit 11 night light on based on ambient light level meas range: 0~1. value = 0 night light on only when sense detects total darkness (default). value = 1 night light on only when a small amount of light is detected. 2 yes yes 1 0 1 0 from to description 0 0 night light on only when sense detects total darkness (default) 1 1 night light on only when a small amount of light is detected 8 temperature scheduled report interval the temperature value report interval time is based on 30 minutes per kick. the value n related to the time in minutes is n x 30 minutes. range: 0~120. default: 6 (6x30 =180 minutes). value = 0 disable temperature scheduled report. 2 yes yes 1 0 120 6 from to description 0 0 disable temperature scheduled report 1 120 n x 30 minutes temperature scheduled report 7 temperature change threshold this parameter determines the change in temperature value resulting in sending temperature value report. range: 0~80 (10 = 1.0 °c or °f; 20 = 2.0 °c). value > 0 and <10 set as 10. default: 10. value = 0 disable temperature value scanning, no report. note: the temperature value is scanned every 5 minutes. a temperature report will be sent if a change over the set threshold valueis detected. 2 yes 1 0 80 10 from to description 0 10 no report sent 11 80 temperature range from 1 80°c 10 night light on duration range: 0~1. value = 0 night light on for 10 seconds (default). value = 1 night light on for 30 seconds. 2 yes yes 1 0 1 0 from to description 0 0 night light on for 10 seconds 1 1 night light on for 30 seconds 1 motion alarm retrigger duration the duration in seconds that the motion alarm would not be sent since last motion alarm reported. the motion alarm report is enabled only when the duration timer has expired. range: 10~3600; default: 240; value = 10 disable motion alarm report. any valid value that great than 10 enable motion alarm report. 2 yes 2 10 3600 240 from to description 10 10 disable motion alarm report 11 3600 enable motion alarm report 3 motion clear duration the period of time in seconds to send motion clear report after motion alarm has reported in security mode. range: 0~3600; default: 10; value = 0 disable motion clear report. 2 yes 2 0 3600 10 from to description 0 0 disable motion clear report 1 3600 enable motion clear report 4 low battery setting report battery low warning message when battery level reaches this value (percentage). range: 10~50 (10%~50%) 2 yes 1 10 50 10 from to description 10 50 low warning message when battery level reaches this value texts