FIBARO Roller Shutter 3 is a device designed to control roller blinds, awnings, venetian blinds, gates and other single phase, Ac powered devices. Roller Shutter 3 allows precise positioning of roller blinds or venetian blind lamellas. The device is equipped with power and energy monitoring. It allows to control connected devices either via the Z-Wave™ network or via a switch connected directly to it.
Want to buy adds it to your wish list and follows Nice for updates. I own it adds it to your collection.
✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Nice shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
FIBARO Roller Shutter 3 is a device designed to control roller blinds, awnings, venetian blinds, gates and other single phase, Ac powered devices. Roller Shutter 3 allows precise positioning of roller blinds or venetian blind lamellas. The device is equipped with power and energy monitoring. It allows to control connected devices either via the Z-Wave™ network or via a switch connected directly to it.
Hardware platform
ZM5101
Short description
FIBARO Roller Shutter 3 is a device designed to control roller blinds, awnings, venetian blinds, gates and other single phase, Ac powered devices.
Association groups
Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
Product identifier
FGR-223
Countries / regions
European Union
Supports smart start
Yes
Certification number
ZC10-22047078
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_NOTIFICATION_V8
Supported notification types
Notification Type Event / State Power Management
Supported / controlled meter types
Meter Type Rate Type Description Electric meter
From to description 0 2 switch type 2 inputs orientation this parameter allows reversing the operation of switches connected to s1 and s2 without changing the wiring. 1 1 0 1 0 from to description 0 1 inputs orientation 3 outputs orientation this parameter allows reversing the operation of q1 and q2 without changing the wiring (in case of invalid motor connection) to ensure proper operation. 1 1 0 1 0 from to description 0 1 outputs orientation 4 alarm configuration 1st slot this parameter determines to which alarm frames and how the device should react. the parameters consist of 4 bytes, three most significant bytes are set according to the official z wave protocol specification. 1 4 0 4 0 from to description 0 4 alarm configuration 1st slot 5 alarm configuration 2nd slot (water) this parameter determines to which alarm frames and how the device should react. the parameters consist of 4 bytes, three most significant bytes are set according to the official z wave protocol specification. 1 4 0 4 0 from to description 0 4 alarm configuration 2nd slot (water) 9 s1 switch scenes sent this parameter determines which actions result in sending scene ids assigned to them. 1 1 0 8 0 from to description 0 8 s1 switch scenes sent 6 alarm configuration 3rd slot (smoke) this parameter determines to which alarm frames and how the device should react. the parameters consist of 4 bytes, three most significant bytes are set according to the official z wave protocol specification. 1 4 0 4 0 from to description 0 4 alarm configuration 3rd slot (smoke) 7 alarm configuration 4th slot (co) this parameter determines to which alarm frames and how the device should react. the parameters consist of 4 bytes, three most significant bytes are set according to the official z wave protocol specification. 1 4 0 4 0 from to description 0 4 alarm configuration 4th slot (co) 8 alarm configuration 5th slot (heat) this parameter determines to which alarm frames and how the device should react. the parameters consist of 4 bytes, three most significant bytes are set according to the official z wave protocol specification. 1 4 0 4 0 from to description 0 4 alarm configuration 5th slot (heat) 10 s2 switch scenes sent this parameter determines which actions result in sending scene ids assigned to them. 1 1 0 8 0 from to description 0 8 s2 switch scenes sent 11 measuring power consumed by the device itself this parameter determines whether the power metering should include the amount of active power consumed by the device itself. 1 1 0 1 0 from to description 0 1 measuring power consumed 17 operating mode this parameter allows adjusting operation according to the connected device. 1 1 1 6 1 from to description 1 6 operating mode 23 time of down movement this parameter determines time needed for roller blinds to reach the bottom. for modes with positioning value is set automatically during calibration, otherwise it must be set manually 1 4 1 65535 6000 from to description 1 65535 time of down movement texts