Plug-Control is a universal, Z-Wave Plus™ compatible, remotely controlled outlet adapter. This device may be applied wherever you want to control electrical devices with up to 2500W load. Plug-Control is equipped with a power and energy metering function. It uses a LED ring to visualize the current load with colour changing illumination and operating mode. This is the smallest and most attractive device of this type available in the world. Plug-Control may be operated using the B-button located on its casing or via any Z-Wave™ compatible controller.
Want to buy adds it to your wish list and follows Nice for updates. I own it adds it to your collection.
✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Nice shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Community photos
Photos from members
No member photos yet.
Reviews
What members say
Sign in to rate Plug-Control E/F and share a photo.
No reviews yet.
Community
Be the first to start a thread about Plug-Control E/F
Plug-Control is a universal, Z-Wave Plus™ compatible, remotely controlled outlet adapter. This device may be applied wherever you want to control electrical devices with up to 2500W load. Plug-Control is equipped with a power and energy metering function. It uses a LED ring to visualize the current load with colour changing illumination and operating mode. This is the smallest and most attractive device of this type available in the world. Plug-Control may be operated using the B-button located on its casing or via any Z-Wave™ compatible controller.
Hardware platform
ZM5202
Short description
Plug-Control is a universal, Z-Wave Plus™ compatible, remotely controlled outlet adapter. This device may be applied wherever you want to control electrical devices with up to 2500W load.
Product identifier
FGWPx-102
Countries / regions
European Union
Certification number
ZC10-22047083
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_SENSOR_MULTILEVEL_V5
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported multilevel sensors
Multilevel Sensor Type Power
Supported notification types
Notification Type Event / State Power Management
Value white association groups
Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
Supported / controlled meter types
Meter Type Rate Type Description Electric meter
From to description 0 0 function inactive 1 1 function activated 3 overload safety switch this function allows to turn off the controlled device in case of exceeding the defined power. controlled device will be turned off even if “always on” function is active (parameter 1). controlled device can be turned back on via b button or sending a control frame. by default this function is inactive. caution! the device has a protection that will turn the load off in the case of detecting current greater than 110% of rated current (>12 a). it is a safety function and it cannot be turned off. after its activation the load can be turned on back again by pressing the b button or sending a control frame. this function is independent of overload safety switch set in the parameter no. 3. 1 2 0 30000 0 from to description 0 0 function inactive 10 30000 (1.0 3000.0 w, step 0.1 w) power threshold 10 high priority power report this parameter determines the minimum percentage change in active power that will result in sending power report to the main controller with the highest priority in the z wave network. by default, plug control immediately sends the power report if the power load changes by 80%. 1 1 1 100 80 from to description 1 99 power change in percent 100 100 reports are disabled 2 remember device status before the power failure this parameter determines how plug control will react in the event of power supply failure (e.g. power outage or taking out from the electrical outlet). after the power supply is back on, plug control can be restored to previous state or remain switched off. this parameter is ignored in „always on” mode the device automatically turns on after plugging it into the socket. 1 1 0 1 0 from to description 0 0 device remains switched off 1 1 device restores the state from before the power failure 23 the response after exceeding defined power values this parameter defines the way that 3rd association group devices are controlled. depends on the actual measured power (as parameters 21 and 22 settings). 1 1 1 6 6 from to description 1 1 turn the associated devices on, once the power drops below down value (parameter 21) 2 2 turn the associated devices off, once the power drops below down value (parameter 21) 3 3 turn the associated devices on, once the power rises above up value (parameter 22) 4 4 turn the associated devices off, once the power rises above up value (parameter 22) 5 5 combination of 1 and 4. turn the associated devices on, once the power drops below down value (parameter 21). turn the associated devices off, once the power rises above up value (parameter 22). 6 6 combination of 2 and 3. turn the associated devices off, once the power drops below down value (parameter 21). turn the associated devices on, once the power rises above up value (parameter 22). 24 switch on value „on/off” association groups the value of basic set command frame sent to the devices associated in „on/off” association groups (2, 3). „on/off (button)” association group in accordance with parameter 20. „on/off (power)” association group in accordance with parameter 23. 1 2 0 255 255 from to description 0 99 sent value 255 255 sent value 31 response to alarm frames this parameter defines how plug control will respond to alarms (device’s status change). in case of values 1 or 2 plug control is operating normally and led ring signals an alarm through time defined in parameter 32 or until the alarm is cancelled. in case of values 5 to 50 plug control does not report status change, power changes, ignores basic set command frames. after time defined in parameter 32 or after the alarm cancellation, connected device is set to the previous state. 1 1 0 50 0 from to description 0 0 no reaction 1 1 turn connected device on 2 2 turn connected device off 5 50 (0.5 5.0 s, step 0.1 s) cyclically change device state with set period 41 led ring colour when controlled device is on when set to 1 or 2, led ring colour will change depending on active power and parameter 40. other colours are set permanently and do not depend on power consumption. 1 1 0 9 1 from to description 6 6 blue 8 8 cyan 3 3 white 7 7 yellow 9 9 magenta 0 0 illumination turned off completely 1 1 colour changes continuously depending on active power 4 4 red 2 2 colour changes in steps depending on active power 5 5 green 43 led ring colour at the z wave network alarm detection this parameter defines the illumination colour in case of z wave alarm. 1 1 0 9 2 from to description 0 0 illumination turned off completely 1 1 no change in colour. led ring colour is determined by settings of parameters 41 or 42 2 2 led ring flashes red/blue/white 3 3 white 4 4 red 5 5 green 6 6 blue 7 7 yellow 8 8 cyan 9 9 magenta 42 led ring colour when controlled device is off this parameter defines the illumination colour after turning off. 1 1 0 9 0 from to description 9 9 magenta 8 8 cyan 7 7 yellow 6 6 blue 5 5 green 4 4 red 3 3 white 0 0 illumination turned off completely 1 1 led ring is illuminated with a colour corresponding to the last measured power, before the controlled device was turned off 50 associations in z wave network security mode this parameter defines how commands are sent in specified association groups: as secure or non secure. parameter is active only in z wave network security mode. this parameter does not apply to 1st „lifeline” group. 1 1 0 3 3 from to description 0 0 none of the groups sent as secure 1 1 2nd group sent as secure 2 2 3rd group sent as secure 3 3 2nd and 3rd group sent as secure texts