Long descriptionOomi MultiSensor looks like a motion sensor and it acts like one too. But it’s also so much more. Installing this 1 piece of Z-Wave® technology is the same as installing 6 pieces of Z-Wave technology. Your home control network will immediately understand motion, temperature, humidity, light, Ultraviolet and Vibration readings wherever MultiSensor installed. Those intelligent readings will equate to intelligence automation. And intelligent automation will give you the perfect, smart home. Short descriptionOomi MultiSensor is a Z-Wave motion sensor, temperature sensor, humidity sensor, lighting sensor, ultraviolet sensor and vibration sensor, all in one package. From to description 0 0 disable waking up for 10 minutes when re power on (battery mode) the multi sensor. 1 1 enable waking up for 10 minutes when re power on (battery mode) the multi sensor. 4 enable/disable the function of motion sensor. this parameter is used to enable/disable the function of motion sensor. 1. value=0, disable. 2. value=1, enable. 0 1 0 0 0 from to description 1 1 enable the function of motion sensor. 0 0 disable the function of motion sensor. 5 which command would be sent when the motion sensor triggered. this parameter is used to configure that which command would be sent when the motion sensor triggered. 1. value=1, send basic set cc. 2. value=2, send sensor binary report cc. 0 1 0 0 1 from to description 1 1 send basic set cc. 2 2 send sensor binary report cc. 41 threshold change in temperature to induce an automatic report. threshold change in temperature to induce an automatic report. note: 1. when the unit is celsius, threshold=value. 2. when the unit is fahrenheit, threshold=value*1.8 the accuracy is 0.1. 0 2 0 0 256 from to description 0 65535 threshold of temperature. 42 threshold change in humidity to induce an automatic report. threshold change in humidity to induce an automatic report. 0 1 0 0 10 from to description 0 100 threshold of humidity 43 threshold change in luminance to induce an automatic report. threshold change in luminance to induce an automatic report. 0 2 0 0 100 44 threshold change in battery level to induce an automatic report. threshold change in battery level to induce an automatic report. 0 1 0 0 10 from to description 0 100 threshold of battery level. 0 1000 threshold of luminance 113 the interval time of sending reports in report group 3 this parameter is used to configure the interval time of the sensor report in report group 3. 0 4 0 0 3600 from to description 5 2678400 the range of interval time is 5 to 2678400. 201 temperature calibration. the calibration value = standard value measure value. e.g. if measure value =25.3℃ and the standard value = 23.2℃, so the calibration value= 23.2℃ 25.3℃= 2.1℃ (0x ffeb). if the measure value =30.1℃ and the standard value = 33.2℃, so the calibration value= 33.2℃ 30.1℃=3.1℃ (0x001 f). 0 1 0 0 0 from to description 32768 32767 the range of calibration value is 32768 to 32767. 203 luminance sensor calibration. the calibration value = standard value measure value. e.g. if measure value =800 lux and the standard value = 750 lux, so the calibration value= 750 – 800= 50 (0x ffce). if the measure value =850 lux and the standard value = 900 lux, so the calibration value= 900 – 850=50 (0x0032). 0 2 0 0 0 from to description 32768 32767 the range of calibration value is 32768 to 32767. 111 the interval time of sending reports in report group 1 this parameter is used to configure the interval time of the sensor report in report group 1. 0 4 0 0 3600 from to description 5 2678400 the range of interval time is 5 to 2678400. 112 the interval time of sending reports in report group 2. this parameter is used to configure the interval time of the sensor report in report group 2. 0 4 0 0 3600 from to description 5 2678400 the range of interval time is 5 to 2678400. 202 humidity sensor calibration. the calibration value = standard value measure value. e.g. if measure value =80 rh and the standard value = 75 rh, so the calibration value= 75 rh – 80 rh= 5 rh (0x fffb). if the measure value =85 rh and the standard value = 90 rh, so the calibration value= 90 rh – 85 rh=5 rh (0x0005). 0 1 0 0 0 from to description 32768 32767 the range of calibration value is 32768 to 32767. 204 ultraviolet sensor calibration. the calibration value = standard value measure value. e.g. if measure value =9 and the standard value = 8, so the calibration value= 8 – 9= 1 (0x fe). if the measure value =7 and the standard value = 9, so the calibration value= 9 – 7=2 (0x02). 0 1 0 0 0 from to description 11 11 the range of calibration value is 11 to 11. 252 enable/disable all configuration parameters to be locked this parameter is used to enable/disable all configuration parameters to be locked. (0 =disable, 1 = enable) 0 1 0 0 0 from to description 0 0 disable all configuration parameters to be locked. 1 1 enable all configuration parameters to be locked. 255 reset to default factory setting this parameter is used to reset product to default factory setting. (there are just 2 values can be used). 0 4 0 0 0 from to description 1 1 resets all configuration parameters to default setting. 1431655765 1431655765 reset the product to default factory setting and be excluded from the z wave network. 45 threshold change in ultraviolet to induce an automatic report. threshold change in ultraviolet to induce an automatic report. 0 1 0 0 2 from to description 0 11 threshold of ultraviolet. 46 enable/disable to send the alarm report of low temperature this parameter is used to enable/disable to send the alarm report of low temperature(< 15℃) 1, value=0, disable. 2, value=1, enable (note: the multi sensor will report the multi level temperature cc with the value=0x ffff to controller if the current temperature is less than 15℃). 0 1 0 0 0 from to description 1 1 enable to send the alarm report of low temperature(&amp;lt; 15℃) 0 0 disable to send the alarm report of low temperature(&amp;lt; 15℃) 3 timeout of the motion sensor this parameter is used to set the timeout for the motion sensor. note: (1), the time unit is second if the value range is in 1 to 255. (2), if the value range is in 256 to 15300, the time unit will be minute and its value should follow the below rules: a), interval time =value/60, if the interval time can be divided by 60 and without remainder. b), interval time= (value/60) +1, if the interval time can be divided by 60 and has remainder. (3), other values will be ignored. 0 2 0 0 240 from to description 1 255 the unit of timeout is second. 256 15300 the unit of timeout is minute. textsID Description Value 2