Long descriptionOomi by Fantem Water Sensor brings intelligence to a new level, one that is suited to both safety and convenience. It contains 4 sensing points, which would be more accurately to detect the presence and absence of water or detect whether there is water leak in some places of your home. The Water Sensor has an inbuilt buzzer that can play alarm sounds to let you know when the water is detected. The Water Sensor is also a security Z-Wave device that supports Over The Air (OTA) for firmware updates. Value updatable by consumer by rf ip (ingress protection) rated battery type value cr123 a sensors value air temperature water flow supported notification types value heat alarm water alarm home security battery quantity value 1 association groupsGroup Number Maximum Nodes Supported End Point ID Description 2 From to description 257 257 keep awake for 10 minutes for battery power mode. 256 256 keep sleep state for battery power mode 0 0 usb power mode 10 set the alarm time for the buzzer when the sensor is triggered. set the alarm time for the buzzer when the sensor is triggered. 0 4 0 0 101968650 from to description 1 255 repeated cycle of buzzer alarm. 256 65535 the time of buzzer keeping on state (msb) 65536 2147483647 the time of buzzer keeping off state 48 enable/disable the sensor report enable/disable the sensor report 0 1 0 0 0 from to description 0 0 disable 1 1 enable. 49 set the upper limit value (overheat). set the upper limit value (overheat). 0 4 0 0 68157696 from to description 0 0 celsius unit 1 1 fahrenheit unit 65536 2147483647 temperature value 50 set the lower limit value (under heat) set the lower limit value (under heat) 0 4 0 0 20971776 from to description 0 0 celsius unit 65536 2147483647 temperature value 1 1 fahrenheit unit 64 set the default unit of the automatic temperature report in parameter 101 103. set the default unit of the automatic temperature report in parameter 101 103. 0 1 0 0 1 from to description 0 0 the unit is celsius. 1 1 the unit is fahrenheit. 84 get the state of tilt sensor get the state of tilt sensor. note: this is a get only parameter. 0 1 0 0 0 from to description 1 1 the water sensor main unit is in vertical direction. 0 0 the water sensor main unit is in horizontal direction. 86 enable/ disable the buzzer. enable/ disable the buzzer. 0 1 0 0 1 from to description 1 1 enable 0 0 disable 88 to set which value of the basic set will be sent to the associated nodes in association group 3 when the sensor probe 1 is triggered. to set which value of the basic set will be sent to the associated nodes in association group 3 when the sensor probe 1 is triggered. 0 1 0 0 0 from to description 1 1 presence of water, send basic set 0x ff, absence of water, send basic set 0x00. 2 2 presence of water, send basic set 0x00, absence of water, send basic set 0x ff. 0 0 send nothing 94 to set which power source level is reported via the battery cc. to set which power source level is reported via the battery cc. 0 1 0 0 0 from to description 0 0 report the usb power level. 1 1 report the cr123 a battery level. 101 to set what unsolicited report would be sent to the lifeline group. to set what unsolicited report would be sent to the lifeline group. 0 1 0 0 3 from to description 3 3 battery report and multilevel sensor report for temperature are enabled. 1 1 battery report is enabled. 0 0 send nothing 2 2 multilevel sensor report for temperature is enabled. 111 to set the interval time of sending reports in report group 1 to set the interval time of sending reports in report group 1. note: 1. the unit of interval time is second if usb power. 2. if battery power, the minimum interval time is equal to wake up interval set by the wake up cc. 0 4 0 0 3600 from to description 5 2678400 available rang is 5 to 2678400 seconds. 135 to set which sensor report can be sent when the water leak event is triggered and if the receiving device is a non multichannel device. to set which sensor report can be sent when the water leak event is triggered and if the receiving device is a non multichannel device. 0 1 0 0 1 from to description 0 0 send nothing 1 1 send notification report to association group 1. 2 2 send configuration 0x88 report to association group 2. 3 3 send notification report to association group 1 and send configuration 0x88 report to association group 2. 136 when the parameter 0x87 is set to 2 or 3, it can get the sensor probes’ status through this configuration value. when the parameter 0x87 is set to 2 or 3, it can get the sensor probes’ status through this configuration value. note: this parameter is a get only parameter. 0 1 0 0 0 from to description 0 0 absence of water is triggered by probe 1. 2 2 presence of water is triggered by probe 2. 1 1 presence of water is triggered by probe 1. 252 enable/disable all configuration parameters to be locked enable/disable all configuration parameters to be locked. 0 1 0 0 0 from to description 1 1 enable. 0 0 disable 2 enable/disable waking up for 10 minutes when re power on (battery mode) the multi sensor. enable/disable waking up for 10 minutes when re power on (battery mode) the multi sensor. 0 1 0 0 0 from to description 0 0 disable 1 1 enable. 57 set the recover limit value of temperature sensor. note: 1. when the current measurement <= (upper limit – recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. after that the upper limit report would be disabled again until the measurement = (lower limit + recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. after that the lower limit report would be disabled again until the measurement >= (lower limit + recover limit). 3. high byte is the recover limit value. low byte is the unit (0x01=celsius, 0x02=fahrenheit). 0 2 0 0 5121 from to description 10 255 available rang is 1.0℉ to 25.5℉ 89 to set which value of the basic set will be sent to the associated nodes in association group 4 when the sensor probe 2 is triggered. to set which value of the basic set will be sent to the associated nodes in association group 4 when the sensor probe 2 is triggered. 0 1 0 0 0 from to description 2 2 presence of water, send basic set 0x00, absence of water, send basic set 0x ff. 0 0 send nothing. 1 1 presence of water, send basic set 0x ff, absence of water, send basic set = 0x00. 255 reset to factory defaults. reset to factory defaults. 0 4 0 0 0 from to description 1431655765 1431655765 reset the product to factory defaults. 1 1 reset all configuration parameters to factory defaults. 201 temperature sensor calibration temperature sensor calibration. note: 1. high byte is the calibration value. low byte is the unit (0x00=celsius, 0x01=fahrenheit) 2. the calibration value (high byte) contains one decimal point. e.g. if the value is set to 20 (0x1400), the calibration value is 2.0 ℃ (eu/au version) or if the value is set to 20 (0x1401), the calibration value is 2.0 ℉(us version) 3. the calibration value (high byte) = standard value measure value. e.g. if measure value =25.3℃ and the standard value = 23.2℃, so the calibration value= 23.2℃ 25.3℃= 2.1℃ (0x eb). if the measure value =30.1℃ and the standard value = 33.2℃, so the calibration value= 33.2℃ 30.1℃=3.1℃ (0x1 f). 0 2 0 0 1 from to description 128 127 available rang is 12.8℃ to 12.7℃. textsID Description Value 1