✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Popp & Co. shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Be the first to start a thread about Mold Detector
Threads post into the Popp & Co. community forum.
Sign in to start a thread in the Popp & Co. community.
Edit history
Loading edit history…
Certified
This device measures the three air quality parameters temperature, humidity and dew point an reports them to a central controller. Beside this, the device can directly control groups of other Z-Wave devices on over- and undershooting a set temperature and/or humidity parameter. This can be used to establish control loops for temperature and humidity. The device wakes up every 4 minutes to measure the values and it will send unsolicited reports when values change. Additionally, the device will report all values on request. The mold detector is actively monitoring the danger of mold in a room based on the temperature and humidity and will issue alarm warnings when critical air conditions met. Wireless Alarm and red and a green blinking LED will indicate a mold condition. This local LED warning function is also available when the device is not included in any Z-Wave network and works stand alone.
Want to buy adds it to your wish list and follows Popp & Co. for updates. I own it adds it to your collection.
This device measures the three air quality parameters temperature, humidity and dew point an reports them to a central controller. Beside this, the device can directly control groups of other Z-Wave devices on over- and undershooting a set temperature and/or humidity parameter. This can be used to establish control loops for temperature and humidity. The device wakes up every 4 minutes to measure the values and it will send unsolicited reports when values change. Additionally, the device will report all values on request. The mold detector is actively monitoring the danger of mold in a room based on the temperature and humidity and will issue alarm warnings when critical air conditions met. Wireless Alarm and red and a green blinking LED will indicate a mold condition. This local LED warning function is also available when the device is not included in any Z-Wave network and works stand alone.
Hardware platform
ZM5101
Short description
The device measures environmental parameters and will warn when the air in the room will allow growth of mold.
Product identifier
POPE700878
Countries / regions
European Union
Supports smart start
Yes
Certification number
ZC10-19026384
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 6
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported multilevel sensors
Multilevel Sensor Type Moisture
Supported notification types
Notification Type Event / State Water Alarm
Value 1 battery type value 1/aa color value white firmware updatable value updatable by consumer by rf sensors value moisture supported notification types value water alarm association groups
Group Number Maximum Nodes Supported End Point ID Description 2
From to description 200 1000 1/10 degree 0 0 disabled 7 humidity upper watermark value this parameter defines a relative humidity. if the measured relative humidity surpasses this watermark a basic command is sent into association group 4 0 1 0 0 0 from to description 0 0 disabled 10 100 % 4 periodic reports this parameter defines the time interval to send an unsolicited report. if the value is set to 0, there will be no periodic reports sent to the controller. however, reports on temperature/humidity changes, managed by configuration parameters 1 and 2, may still be active. 0 2 0 0 43200 from to description 0 0 disabled 900 1 seconds 8 humidity lower watermark value this parameter defines a relative humidity. if the measured temperature drops below this relative humidity a basic command is sent into association group 5 0 1 0 0 0 from to description 0 0 disabled 1 90 % 9 low temperature trigger basic set command value this defines what basic command shall be sent out into association group 3 0 1 0 0 1 from to description 0 1 value 5 temperature upper watermark value this parameter defines a temperature. if the measured temperature surpasses this watermark a basic command is sent into association group 2. 0 2 0 0 0 from to description 0 0 disabled 1 1000 1/10 degree 10 high temperature trigger basic set command value this defines what basic command shall be sent out into association group 2 0 1 0 0 0 from to description 0 1 value 11 low humidity trigger basic set command value this defines what basic command shall be sent out into association group 5 0 1 0 0 1 from to description 0 1 value texts