The Vivint Element Smart Thermostat has an elegantly simple design making it easy for anyone to use. It’s hidden display comes to life when you need it, providing clear information and simple controls. This simplicity purposefully masks Element’s true intelligence. Element works in concert with the Vivint SkyControl system, leveraging an unmatched understanding of home routines and activity levels. Element automatically and dynamically adjusts to match home activities and ensure a personalized balance of comfort & energy savings. Because Element uses the latest in Z-Wave technology, it is compatible with all common heating & cooling systems without the need for any new wiring. It can also be wirelessly updated, ensuring it will continue to evolve to meet consumers’ ever-changing comfort & energy savings needs.
Long descriptionThe Vivint Element Smart Thermostat has an elegantly simple design making it easy for anyone to use. It’s hidden display comes to life when you need it, providing clear information and simple controls. This simplicity purposefully masks Element’s true intelligence. Element works in concert with the Vivint SkyControl system, leveraging an unmatched understanding of home routines and activity levels. Element automatically and dynamically adjusts to match home activities and ensure a personalized balance of comfort & energy savings. Because Element uses the latest in Z-Wave technology, it is compatible with all common heating & cooling systems without the need for any new wiring. It can also be wirelessly updated, ensuring it will continue to evolve to meet consumers’ ever-changing comfort & energy savings needs. From to description 0 4 0 disabled 1 0.5 f 5 humidity reporting threshold the humidity threshold configuration set command sets the reporting threshold for changes in the relative humidity as detected by the thermostat. 0 1 0 0 2 from to description 0 3 0=disabled 1=3%rh 2=5%rh 3=10%rh 6 auxiliary/emergency the auxiliary/emergency configuration command enables or disables auxiliary / emergency heating in the thermostat. 0 1 0 0 0 from to description 0 1 0=disabled 1=enabled 7 thermostat swing temperature the thermostat swing temperature configuration command sets swing temperature on the thermostat. 0 1 0 0 2 from to description 1 8 the thermostat swing temperature is in units of 0.5 degrees fahrenheit. a value of 0x01 is 0.5 f and 0x02 is 1.0 f. the supported values may vary from thermostat to thermostat but typically the allowed values are 0.5 f (0x01) to 4.0 f (0x08). 8 thermostat diff temperature the thermostat differential temperature configuration command sets the differential temperature for multi stage hvac systems. 0 2 0 0 1028 from to description 0 0 "the thermostat differential mode determines which differential temperature to set. valid values are 0x00 (heat) or cool (0x01) the thermostat differential temperature is in units of 0.5 degrees fahrenheit. a value of 0x04 is 2.0 f and 0x06 is 3.0 f. the differential temperature must be an integer value. non integer values, such as 1.5 f (0x03), should not be used. the supported values may vary from thermostat to thermostat but typically, the allowed values are 2.0 f (0x04) to 6.0 f (0x0 c). " 4 c wire / battery status the c wire / battery status configuration report command returns the status of the thermostat power source. the power state is fixed when the thermostat joins the network. 0 1 0 0 0 from to description 1 2 c wire (0x01) or battery (0x02) 11 simple ui mode enable/disable the parameter is set the auxiliary simple mode. 0 1 0 0 0 from to description 0 1 0=normal 1=simple 10 temperature reporting filter the temperature reporting filter configuration command sets upper and lower bounds of the ambient temperature reporting. the thermostat will not report ambient temperature changes if the ambient temperature is below the upper bound or above the lower bound. 0 4 0 0 32000 from to description 0 0 "byte 1 is the lower bound and can be 0 to 124 byte 2 is the upper bound and can be 0 to 124 " 17 temperature calibration (ct200) this configuration is used to set the temperature offset of the thermostat. 0 1 0 0 0 from to description 6 6 the valid values are from 6 to 6. 2 hvac settings this parameter is used to set and retrieve the current hvac settings of the thermostat.. 0 4 0 0 0 from to description 0 0 "cooling type (0, 1, 2, 3) heating type (0, 1, 2, 3) heating fuel (1, 2, 3, 4, 5) number of heat stages (not heat pump) / number of aux stages (heat pump) (1, 2)  a terminal assignment (0, 1, 2, 3, 4) number of heat pump stages (1, 2)  o/b wire selection (1,2)  cooling stages (1, 2)" 9 thermostat recovery mode the thermostat recovery mode configuration command sets the hvac recovery mode type. the recovery mode determines when additional hvac stages are turned off as the ambient temperature returns to the target temperature. 0 1 0 0 2 from to description 1 2 the thermostat recovery mode can be either fast (0x01) or economy (0x02). 3 utility lock enable/disable the utility lock configuration set command enables or disables the utility lock. if the utility lock is enabled, the setpoint cannot be modified directly via the thermostat screen. 0 1 0 0 0 from to description 0 255 if set to 0, the utility lock is disabled, all other values will enable the utility lock. textsID Description Value 1