From to description 0 0 0 0 dimmer mode 1 1 switch mode 1 input switch type available configuration parameters (data type is 1 byte dec): • default value 0 • 0 mono stable switch type (push button) • 1 bi stable switch type 0 1 0 0 0 from to description 1 1 bi stable switch type 0 0 mono stable switch type (push button) 10 activate / deactivate functions all on / all off din dimmer module responds to commands all on / all off that may be sent by the main controller or by other controller belonging to the system. 0 2 0 0 255 from to description 0 0 all on is not active, all off is not active 1 1 all on is not active, all off active 2 2 all on active, all off is not active 255 255 all on active, all off active 11 automatic turning off output after set time turns off the output after set time. 0 2 0 0 0 from to description 0 0 auto off disabled 1 32536 = 1second 32536 seconds auto off enabled with define time, step is 1 second 42 power reporting in watts by time interval set value means time interval (0 – 32767) in seconds, when power report is send. reporting enabled. power report is send with time interval set by entered value. please note, that too fast reporting can cause too much z wave traffic resulting in z wave poor response. 0 2 0 0 0 from to description 0 0 reporting disabled 1 32767 = 1 second 32767 seconds. reporting enabled. power report is send with time interval set by entered value. please note, that too fast reporting can cause too much z wave traffic resulting in z wave poor response 60 minimum dimming value the minimum level may not be higher than the maximum level! 1% min. dimming value is defined by z wave multilevel device class. when the switch type is selected as bi stable, it is not possible to dim the value between min and max. if switch multilevel set is set to the value “0”, the output is turned off. if switch multilevel set is set to the value “1”, the output is set to the minimum diming value. 0 1 0 0 1 from to description 1 1 = 1% (minimum dimming value) 1 98 = 1% 98%, step is 1%. minimum dimming values is set by entered value. 61 maximum dimming value the maximum level may not be lower than the minimum level! 99% max. dimming value is defined by z wave multilevel device class. when the switch type is selected as bi stable, it is not possible to dim the value between min and max. 0 1 0 0 99 from to description 99 99 = 99% (maximum dimming value) 2 99 = 2% 99%, step is 1%. maximum dimming values is set by entered value 65 dimming time (soft on/off) set value means time of moving the din dimmer between min. and max. dimming values by short press of push button i or controlled through ui (basic set). 0 2 0 0 100 from to description 100 100 = 1s 50 255 = 500 mseconds 2550 mseconds (2,55s), step is 10 mseconds 66 dimming time when key pressed time of moving the din dimmer between min. and max dimming values by continues hold of push button i or associated device. 0 2 0 0 3 from to description 3 3 = 3s 1 255 1 second 255 seconds 68 dimming duration this parameter is used with association group 3. the duration field must specify the time that the transition should take from the current value to the new target value. a supporting device should respect the specified duration value. 0 1 0 0 0 from to description 0 0 dimming duration according to parameter 66 1 127 from 1 to 127 seconds 110 temperature sensor offset settings set value is added or subtracted to actual measured value by sensor. available configuration parameters (data type is 2 byte dec): • default value = 32536 • 32536 = offset is 0.0 c • 1 100 = value from 0.1 °c to 10.0 °c is added to actual measured temperature. • 1001 1100 = value from 0.1 °c to 10.0 °c is subtracted to actual measured temperature. 0 2 0 0 32536 from to description 1001 1100 value from 0.1 degrees celsius to 10.0 degrees celsius to 10.0 degrees celsius to 10.0 degrees celsius is subtracted to actual measured temperature 32536 32536 offset is 0.0 degrees celsius 1 100 value from 0.1 degrees celsius to 10.0 degrees celsius is added to actual measured temperature 120 digital temperature sensor reporting digital temperature sensor reporting if digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. available configuration parameters (data type is 1 byte dec): • default value 5 = 0,5°c change • 0 = reporting disabled • 1 127 = 0,1°c 12,7°c, step is 0,1°c 0 1 0 0 5 from to description 1 127 = 0,1 degrees celsius 12,7 degrees celsius, step is 0,1 degrees celsius 5 5 0,5 degrees celsius change 0 0 reporting disabled 67 ignore start level this parameter is used with association group 3.a receiving device should respect the start level if the ignore start level bit is 0. a receiving device must ignore the start level if the ignore start level bit is 1. 0 1 0 0 0 from to description 0 0 respect start level 1 1 ignore start level textsID Description Value 2