✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Secure shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Sign in to start a thread in the Secure community.
Edit history
Loading edit history…
Certified
SIR 321 is a Z-Wave Plus countdown timer with one relay and support of duration base schedule that can be used to control any electrical appliances rated up to 3 kW. With an external temperature sensor, SIR 321 can measure room temperature and send temperature report on regular interval or delta temperature change as per configuration. It forms part of central heating control system, it can be operated by any third party controllers using ‘Binary Switch command class’ commands. SIR 321 will act as a repeater once added into the Z- Wave network, providing an alternative communication route for units which otherwise would not be within communication distance of each other. SIR 321 has a fail-safe mode where by the relay is turned OFF if another 'Binary switch SET' or 'Basic SET' command has not been received within 60 minutes.
Want to buy adds it to your wish list and follows Secure for updates. I own it adds it to your collection.
SIR 321 is a Z-Wave Plus countdown timer with one relay and support of duration base schedule that can be used to control any electrical appliances rated up to 3 kW. With an external temperature sensor, SIR 321 can measure room temperature and send temperature report on regular interval or delta temperature change as per configuration. It forms part of central heating control system, it can be operated by any third party controllers using ‘Binary Switch command class’ commands. SIR 321 will act as a repeater once added into the Z- Wave network, providing an alternative communication route for units which otherwise would not be within communication distance of each other. SIR 321 has a fail-safe mode where by the relay is turned OFF if another 'Binary switch SET' or 'Basic SET' command has not been received within 60 minutes.
Hardware platform
ZM5202
Short description
SIR 321 is a Z-Wave Plus countdown timer having one relay and support of duration base schedule that can be used to control any electrical appliances, it can measure and report room temperature.
Product identifier
MAX10Y-376
Countries / regions
European Union
Certification number
ZC10-20127001
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 2
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
Supported multilevel sensors
Multilevel Sensor Type Air temperature
Value white switch load capacity watts value 3000 watts firmware updatable value not updatable ip (ingress protection) rated switch load capacity current value 13 amps resistive or 3 amps inductive association groups
Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 3
From to description 0 127 unsolicited multilevel sensor report in °c scale 128 255 unsolicited multilevel sensor report in °f scale 5 cut off temperature when temperature reaches at cut off temperature point than relay will be switched off. in case of °f scale: minimum value is 320 and maximum value is 2120 (in 0.1 °f resolution) 1 2 0 1000 0 from to description 0 0 cut off temperature feature is disable 1 1000 cut off temperature value in °c (in 0.1 °c resolution) 1 enable/disable fail safe timer for any non zero value fail safe timer of 60 minutes starts after valid 'switch binary set' or 'basic set' command, timer is reloaded with 60 minutes on every successful communication with the controller. in case of communication failure with the controller for 60 minutes. fail safe timer will switch off the relay and communication failure indicated on rf led. 1 1 127 127 0 from to description 127 1 enable fail safe timer. 0 0 diable fail safe timer. 1 127 enable fail safe timer. 4 delta configuration temperature report configuration of delta temperature for delta temperature change based reporting. in case of °f scale: minimum value is 0 and maximum value is 500 (in 0.1 °f resolution) 1 2 0 100 0 from to description 0 0 delta temperature reporting is disable 1 100 delta temperature value in °c (in 0.1 °c resolution) texts