✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Zooz shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Community photos
Photos from members
No member photos yet.
Reviews
What members say
Sign in to rate UNIVERSAL RELAY and share a photo.
No reviews yet.
Community
Be the first to start a thread about UNIVERSAL RELAY
FEATURES: - Powerful dry contact NO/NC relays to control loads up to 20 A for NO - Perfect for DC motors, pumps, commercial gates, or HVAC equipment - Control up to 2 connected loads independently or together - Z-Wave or optional wall switch control (toggle or momentary type) - Monitor inputs independently from output control - Built-in timers for each relay to simplify automation - Built-in Z-Wave Plus signal repeater to extend network range - Powered by 12-24 V DC/AC or USB C port for easy set-up - Wall mounting and minimal design for clean installation - NEW 700 Z-Wave chip, S2 security, and SmartStart SPECS: - Model Number: ZEN17 - Z-Wave Signal Frequency: 908.42 MHz - Power: 12-24 V DC/AC or USB C (DON’T use laptop / tablet chargers) - Maximum Load: NO relays: 20 A, NC relays: 10 A - Inputs: dry contact or 12-24 V AC/DC (use 1 input type at a time!) - Range: Up to 200 feet line of sight - Operating Temperature: 32-104° F (0-40° C) - Installation and Use: Indoor only
Want to buy adds it to your wish list and follows Zooz for updates. I own it adds it to your collection.
FEATURES: - Powerful dry contact NO/NC relays to control loads up to 20 A for NO - Perfect for DC motors, pumps, commercial gates, or HVAC equipment - Control up to 2 connected loads independently or together - Z-Wave or optional wall switch control (toggle or momentary type) - Monitor inputs independently from output control - Built-in timers for each relay to simplify automation - Built-in Z-Wave Plus signal repeater to extend network range - Powered by 12-24 V DC/AC or USB C port for easy set-up - Wall mounting and minimal design for clean installation - NEW 700 Z-Wave chip, S2 security, and SmartStart SPECS: - Model Number: ZEN17 - Z-Wave Signal Frequency: 908.42 MHz - Power: 12-24 V DC/AC or USB C (DON’T use laptop / tablet chargers) - Maximum Load: NO relays: 20 A, NC relays: 10 A - Inputs: dry contact or 12-24 V AC/DC (use 1 input type at a time!) - Range: Up to 200 feet line of sight - Operating Temperature: 32-104° F (0-40° C) - Installation and Use: Indoor only
Hardware platform
ZGM130
Short description
2 Dry Contact NO-C-NC Relays with Adjustable 12-24 and Dry Contact Inputs: Add Z-Wave to Most Analog Devices
Product identifier
ZEN17
Countries / regions
United States of America
Supports smart start
Yes
Certification number
ZC12-21030204
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values Flag ReInclude 17
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
Supported notification types
Notification Type Event / State Smoke Alarm
Value gray switch type value dry contact electric load type value incandescent fluorescent mlv (magnetic) led inductive (e.g. motor) firmware updatable value updatable by consumer by rf loads controlled value 2 association groups
Group Number Maximum Nodes Supported End Point ID Group Name Description 1
From to description 2 2 hours 0 0 minutes 1 1 seconds 1 on off status after power failure set the on off status for the relays after power failure. 2 1 0 4 1 from to description 0 0 all relays forced to off (regardless of state prior to power outage) 1 1 all relays remember and restore on/off status after power failure (default) 2 2 all relays forced to on (regardless of state prior to power outage) 3 3 relay 1 remembers and restores on/off status after power failure, relay 2 forced to on 4 4 relay 2 remembers and restores on/off status after power failure, relay 1 forced to on. 24 dc motor mode sync r1 and r2 together to prevent them from being activated at the same time. 2 1 0 1 0 from to description 1 1 dc motor mode enabled (relay will check the status of the other relay aer being triggered and will shut the other relay off before activating so that only one of the relays is on at the same time) 0 0 dc motor mode disabled (relays will activate whenever they're triggered) 3 input type for relay 2 (s2) choose the wall switch or input type you want to connect to the s2 c terminals. click twice, holding the z wave button for 5 seconds the second time to change to garage mode manually. important: if you set this parameter to value 4 10, you’ll need to exclude and re include the device (without changing any settings) so that a child device is created for the input of your choice! 2 1 0 10 2 from to description 0 0 momentary for lights only 1 1 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down) 2 2 toggle switch (state changes whenever the switch is toggled) 3 3 garage door (momentary mode for z wave control) 4 4 leak alarm (water sensor) 5 5 heat alarm 6 6 motion alert 7 7 open/close alert (door sensor) 8 8 co alarm 9 9 co2 alarm 10 10 on/off report (dry contact switch/sensor) yes 2 input type for relay 1 (s1) choose the wall switch or input type you want to connect to the s1 c terminals. press and hold the z wave button for 5 seconds to change to garage mode manually. important: if you set this parameter to value 4 10, you’ll need to exclude and re include the device (without changing any settings) so that a child device is created for the input of your choice! 2 1 0 10 2 from to description 0 0 momentary for lights only 1 1 toggle switch (light on when the switch is toggled up, light off when the switch is toggled down); 2 2 toggle switch (state changes whenever the switch is toggled) 3 3 garage door (momentary mode for z wave control) 4 4 leak alarm (water sensor) 5 5 heat alarm 6 6 motion alert 7 7 open/close alert (door sensor) 8 8 co alarm 9 9 co2 alarm 10 10 on/off report (dry contact switch/sensor) yes 6 auto turn off timer for relay 1 use this parameter to set the time after which you want the device connected to relay 1 to automatically turn off once it has been turned on. the number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in par. 15). 2 4 0 65535 0 from to description 0 0 disabled 1 65535 minutes/seconds/hours 7 auto turn on timer for relay 1 use this parameter to set the time after which you want the device connected to relay 1 to automatically turn on once it has been turned off. the number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in par. 16). 2 4 0 65535 0 from to description 0 0 disabled 1 65535 minutes/seconds/hours 9 auto turn on timer for relay 2 use this parameter to set the time after which you want the device connected to relay 2 to automatically turn on once it has been turned off. the number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in par. 18). 2 4 0 65535 0 from to description 0 0 disabled 1 65535 minutes/seconds/hours 8 auto turn off timer for relay 2 use this parameter to set the time after which you want the device connected to relay 2 to automatically turn off once it has been turned on. the number entered as value corresponds to the number of minutes, seconds, or hours (set the unit in par. 17). 2 4 0 65535 0 from to description 0 0 disabled 1 65535 minutes/seconds/hours 10 input trigger for relay 1 choose if you’d like the connected input (switch) on s1 c / vc c to trigger the load connected to r1 or if you want to use the input reports for monitoring only and separate the output from the input. 2 1 0 1 1 from to description 0 0 input trigger disabled 1 1 input trigger enabled (default) 11 input trigger for relay 2 choose if you’d like the connected input (switch) on s2 c / vc c to trigger the load connected to r2 or if you want to use the input reports for monitoring only and separate the output from the input. 2 1 0 1 1 from to description 0 0 input trigger disabled 1 1 input trigger enabled (default) 5 led indicator control choose if you want the led indicator to turn on when any of the relays are on or if all of them are off, or if you want it to remain on or off at all times. 2 1 0 3 0 from to description 0 0 led indicator is on when all of the relays are off, led indicator is off when any of the relays is on (default); 1 1 led indicator is on when any of the relays is on, led indicator is off when all of the relays are off; 2 2 led indicator is always off; 3 3 led indicator is always on texts