✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if B.One shuts down the app or the servers. One thing to note: companion app hasn't been updated in over 2 years.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Companion app hasn't been updated in over 2 years
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Community photos
Photos from members
No member photos yet.
Reviews
What members say
Sign in to rate B.One Dual Relay and share a photo.
No reviews yet.
Community
Be the first to start a thread about B.One Dual Relay
Dual Relay is a Z-Wave power binary switch device based on Z-Wave enhanced 232 slave library V6.51.10. You can use it to control your home light or bulbs on/off. It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Relay Switch. It can also be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. It is a security Z-Wave plus device, so a security enabled controller is needed for take full advantage of all functionally for the Relay Switch. It also supports the Over The Air (OTA) feature for the product’s firmware upgrade. As soon as Dual Relay is removed from a Z-Wave network it will be restored into default factory setting.
Want to buy adds it to your wish list and follows B.One for updates. I own it adds it to your collection.
Dual Relay is a Z-Wave power binary switch device based on Z-Wave enhanced 232 slave library V6.51.10. You can use it to control your home light or bulbs on/off. It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Dual Relay Switch. It can also be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. It is a security Z-Wave plus device, so a security enabled controller is needed for take full advantage of all functionally for the Relay Switch. It also supports the Over The Air (OTA) feature for the product’s firmware upgrade. As soon as Dual Relay is removed from a Z-Wave network it will be restored into default factory setting.
Hardware platform
ZM5101
Short description
Z-Wave Dual Relay Switch
Product identifier
B1DR01-ZW-IN
Countries / regions
India
Certification number
ZC10-19116801
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 80
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_SCENE_ACTUATOR_CONF
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported notification types
Notification Type Event / State Heat Alarm
Value toggle z wave scene type value scene electric load type firmware updatable value updatable by consumer by rf supported notification types value heat alarm association groups
Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
From to description 0 0 send nothing 1 1 send hail cc 2 2 send basic cc report 3 3 send hail cc when using the manual switch to change the load state. 81 to set which notification would be sent to the associated nodes in association group 3 to set which notification would be sent to the associated nodes in association group 3 when using the external switch 1 to switch the loads. 0 1 0 0 1 from to description 0 0 send nothing 1 1 send basic set cc 82 to set which notification would be sent to the associated nodes in association group 4 to set which notification would be sent to the associated nodes in association group 4 when using the external switch 2 to switch the loads. 0 1 0 0 1 from to description 0 0 send nothing 1 1 send basic set cc 83 configure the state of led when it is in 3 modes configure the state of led when it is in 3 modes (energy mode, momentary indicate mode, night light mode) 0 1 0 0 0 from to description 0 0 energy mode. the led will follow the status (on/off). 1 1 momentary indicate mode. when the state of switch’s load changed, the led will follow the status (on/off) of its load, but the led will turn off after 5 seconds if there is no any switch action. 2 2 night light mode. the led will remain on state. 84 set the on/off time of the led when it is in night light mode. set the on/off time of the led when it is in night light mode. 0 4 0 0 301991936 from to description 16777216 16777276 the hour time of on 0 60 the minute time of off 256 316 the hour time of off 65536 65596 the minute time of on 86 set appointment 1 set the on time of output load. 0 4 0 0 8327680 from to description 0 60 the minute value of on time 256 316 the hour value of on time 65536 65543 the day value (mon to sun) 16777215 16777215 disable the setting. 16777216 16777216 enable the setting. 87 set appointment 2 set the off time of output load. 0 4 0 0 8327680 from to description 0 60 the minute value of on time 256 316 the hour value of on time 65536 65543 the day value (mon to sun) 16777215 16777215 disable the setting. 16777216 16777216 enable the setting. 120 configure the external switch mode for s1. configure the external switch mode for s1. 0 1 0 0 0 from to description 0 0 enter automatic identification mode 1 1 2 state switch mode 2 2 3 way switch mode 3 3 momentary push button mode 121 configure the external switch mode for s2. configure the external switch mode for s2. 0 1 0 0 0 from to description 0 0 enter automatic identification mode 1 1 2 state switch mode 2 2 3 way switch mode 3 3 momentary push button mode 4 overheat protection. output load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100 ℃. 0 1 0 0 0 from to description 0 0 disable 1 1 enable 252 lock/unlock configuration parameters lock/unlock configuration parameters. 0 1 0 0 0 from to description 0 0 unlock 1 1 lock 122 set the control destination for external switch s1 set the control destination for external switch s1 0 1 1 3 3 from to description 1 1 control the output loads of itself. 2 2 control the other nodes 3 3 control the output loads of itself and other nodes. 123 set the control destination for external switch s2 set the control destination for external switch s2 1 1 1 3 3 from to description 1 1 control the output loads of itself. 2 2 control the other nodes. 3 3 control the output loads of itself and other nodes. 255 reset the dual relay switch reset the dual relay switch to factory default. 0 4 0 0 0 from to description 1431655765 1431655765 reset to factory default setting and removed from the z wave network 0 0 reset all configuration parameters to factory default setting texts