This product can be included and operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Want to buy adds it to your wish list and follows Coolcam for updates. I own it adds it to your collection.
✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Coolcam shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Companion app is actively updated
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
This product can be included and operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Hardware platform
ZM5202
Short description
This device is an audible and visual alarm with 10 different sounds and it is based on Z-Wave™ Plus technology.
Product identifier
NAS-AB02ZE
Countries / regions
European Union
Supports smart start
Yes
Certification number
ZC10-18096227
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 7
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
Supported multilevel sensors
Multilevel Sensor Type General purpose
Supported notification types
Notification Type Event / State Home Security
Value 2 communications connections value none gateway has preferred partners sensors value open/closed (binary) supported notification types value home security siren battery type value cr123 a color value white firmware updatable value updatable by professional/technician association groups
Group Number Maximum Nodes Supported End Point ID Description 1
From to description 1 2 default siren on mode 8 alarm led enable this parameter defines the default led enable status when siren is on for alarm sound mode. if parameter is set to ‘0’, led will be disable. if parameter is set t0 ‘1’, led will be enable. when siren is on, the led will blink. 0 1 0 0 1 from to description 0 1 alarm mode switching 5 alarm sound index this parameter defines the alarm sound index for siren play different sound when alarm occurs. there are 10 different sound for user selection. 0 1 0 0 10 from to description 1 10 alarm sound index 3 door bell sound duration time this parameter defines the door bell sound duration time when siren receives a door/window sensor notification report or an alarm command (basic set = 0x02) from controller. the door bell sound will be played always if this parameter is set to ‘0x7 f’. the door bell sound will not be played if this parameter is set to ‘0’. other values are the door bell sound playing duration time. unit: time. the value for this parameter is unsigned value. 0 1 0 0 1 from to description 0 127 door bell sound duration time 4 door bell sound volume this parameter defines the output volume when siren plays alarm sound. door bell sound volume is divided into 3 stages: low (parameter is set to ‘1’), middle (parameter is set to ‘2’), high(parameter is set to ‘3’). default value is ‘1’. 0 1 0 0 1 from to description 1 3 door bell sound volume 6 door bell sound index this parameter defines the door bell sound index for siren play different sound when alarm occurs. there are 10 different sound for user selection. 0 1 0 0 9 from to description 1 10 door bell sound index 1 alarm sound volume this parameter defines the output volume when siren plays door bell sound. door bell sound volume is divided into 3 stages, low (parameter is set to ‘1’), middle (parameter is set to ‘2’), high (parameter is set to ‘3’). default value is ‘3’. 0 1 0 0 3 from to description 1 3 alarm sound volume 2 alarm sound duration time this parameter defines the alarm sound duration time when siren receive an alarm sensor notification report or an alarm command from controller. the duration time is divided into 5 stages: ◆ siren is not on (parameter is set to ‘0’), ◆ 30 second (parameter is set to ‘1’), ◆ 1 minute (parameter is set to ‘2’), ◆ 5 minute (parameter is set to ‘3’) ◆ siren is always on until battery is dead (parameter is set to ‘0x7 f’). default value is ‘2’. the value for this parameter is unsigned value. 0 1 0 0 2 from to description 127 127 always alarm 0 3 alarm sound duration time 9 door bell led enable this parameter defines the default led enable status when siren is on for door bell sound mode. if parameter is set to ‘0’, led will be disable. if parameter is set t0 ‘1’, led will be enable. when siren is on, the led will blink. 0 1 0 0 0 from to description 0 1 door bell led enable texts