Long descriptionThe Devolo HC Switch FM controls on/off function for one electrical device. It measures power consumption of the connected device, and can be paired with a digital temperature sensor (sold separately). It supports push-button/momentary switches and toggle switches (default). The connection of a digital temperature sensor means you can create complex scenes and control any device relative to a set temperature range. The Devolo HC Switch FM also acts as a Z-Wave repeater to improve the range and stability of the Z-Wave network. Short descriptionThe Devolo HC Switch FM is ideal for remotely controlling one light or electrical device (door lock, door opener, small appliances, etc.). Value air temperature neutral wire required color value white switch load capacity watts value 2300 w electric load type value incandescent elv (electronic) led inductive (e.g. motor) supported meter type value electric energy switch load capacity current value 10 a supported notification types value smoke alarm co alarm co2 alarm heat alarm water alarm home security power management gas alarm switch type value push button association groupsGroup Number Maximum Nodes Supported End Point ID Description 1 From to description 0 0 auto off disabled 1 32535 1 32535 seconds (or milliseconds – see parameter no. 15) auto off timer enabled for a given amount of seconds (or milliseconds) 100 enable / disable endpoint i2 or select the notification type and the notification event choose whether the endpoint i2 is disabled (and not shown on the ui) or enabled (and displayed on the ui). by enabling this endpoint (setting it to be either a notification sensor or a binary sensor), the user also selects a notification type and a notification event for which notification reports will be sent (in case the endpoint is configured as a notification sensor). endpoint device type selection: notification sensor (1 6): generic type sensor notification, specific type notification sensor sensor binary (9): generic type sensor binary, specific type not used values (size is 1 byte dec): note 1: after changing the values of the parameter, first exclude the device (without setting the parameters to their default values), then wait at least 30 seconds to re include the device! note 2: when the parameter is set to value 9 the notifications are sent for the home security notification type. 0 1 0 0 0 from to description 0 0 endpoint, i2 disabled 1 1 home security; motion detection, unknown location 2 2 co; carbon monoxide detected, unknown location 3 3 co2; carbon dioxide detected, unknown location 4 4 water alarm; water leak detected, unknown location 5 5 heat alarm; overheat detected, unknown location 6 6 smoke alarm; smoke detected, unknown location 9 9 sensor binary 63 choose normally closed or normally open for q⬆ load set value determines the type of the device connected to the q⬆ output. the output type can be normally open (no) or normally closed (nc). 0 1 0 0 0 from to description 0 0 when switch/device is off the output is 0 v (no). 1 1 when switch/device is off the output is 230 v (nc). 101 enable / disable endpoint i3 or select the notification type and the notification event choose whether the endpoint i3 is disabled (and not shown on the ui) or enabled (and displayed on the ui). by enabling this endpoint (setting it to be either a notification sensor or a binary sensor), the user also selects a notification type and a notification event for which notification reports will be sent (in case the endpoint is configured as a notification sensor). endpoint device type selection: notification sensor (1 6): generic type sensor notification, specific type notification sensor sensor binary (9): generic type sensor binary, specific type not used note 1: after changing the values of the parameter, first exclude the device (without setting the parameters to their default values), wait at least 30 seconds and then re include the device! note 2: when the parameter is set to the value 9 the notifications are sent for the home security notification type. 0 1 0 0 0 from to description 1 1 home security; motion detection, unknown location 2 2 co; carbon monoxide detected, unknown location 3 3 co2; carbon dioxide detected, unknown location 4 4 water alarm; water leak detected, unknown location 5 5 heat alarm; overheat detected, unknown location 0 0 endpoint, i2 disabled 6 6 smoke alarm; smoke detected, unknown location 9 9 sensor binary 110 temperature sensor offset settings set value is added to or subtracted from the actual measured value to adjust the temperature report sent by an external sensor (sold separately). this parameter only applies to celcius temperature unit (the fahrenheit unit is currently not supported). 0 2 0 0 32536 from to description 1 100 where 1 stands for 0.1 and 100 stands for 10.00 degrees added to the actual measurement 1001 1100 where 1001 stands for 0.1 degrees and 1100 stands for 10.0 degrees subtracted from the actual measurement 32536 32536 offset is 0 degrees. 2 input 2 contact type with this parameter, input 2 contact type is defined. 0 1 0 0 0 from to description 0 0 no (normally open) input type 1 1 nc (normally close) input type 3 input 3 contact type with this parameter, input 3 contact type is defined. 0 1 0 0 0 from to description 0 0 no (normally open) input type 1 1 nc (normally close) input type 120 temperature sensor reporting threshold if an external digital temperature sensor (sold separately) is connected to the device, it reports temperature readings based on the threshold defined in this parameter. this parameter only applies to the degrees temperature unit (the fahrenheit unit is currently not supported). 0 1 0 0 5 from to description 0 0 reporting disabled 1 127 where 1 stands for 0.1 and 127 stands for 12.7 degrees 5 5 0.5 degrees celsius 1 in wall switch type for load 1 (q⬆) to control i1 with this parameter, you can select between push button (momentary) and on/off toggle switch types. 0 1 0 0 1 from to description 1 1 on/off toggle switch 0 0 push button (momentary) 10 activate / deactivate all on / all off functionality devolo relay device responds to commands all on / all of 0 2 0 0 255 from to description 1 1 all on not active, all off active 2 2 all on active, all off not active 255 255 all on active, all off active 0 0 all on not active, all off not active 42 watt power consumption reporting time threshold for q⬆ load set value refers to the time interval with which power consumption in watts is reported (0 – 32535 seconds). if 300 is entered (by default), energy consumption reports will be sent to the gateway (hub) every 300 seconds (or 5 minutes). 0 2 0 0 300 from to description 0 0 power consumption reporting disabled 1 32535 1 32535 seconds. power consumption reporting enabled. report is sent according to time interval (value) set here. textsID Description Value 2