This in-wall dual relay switch module is a transceiver which is a Z-Wave Plus™ enabled device and is fully compatible with any Z-Wave™ enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. There are many kind of application by using the module to switch AC power On and Off, one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. This in-wall switch module is able to detect Instant power wattage and overload current (7.5A) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status.
Long descriptionThis in-wall dual relay switch module is a transceiver which is a Z-Wave Plus™ enabled device and is fully compatible with any Z-Wave™ enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. There are many kind of application by using the module to switch AC power On and Off, one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. This in-wall switch module is able to detect Instant power wattage and overload current (7.5A) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status. From to description 1 1 relay1 can be controlled and will report. 2 2 relay2 can be controlled and will report 3 3 relay1 and relay2 can be controlled and report. 1 watt meter report period if the setting is configured for 1hour (set value =720), the pan04 will report its instant power consumption every 1 hour to the node of correspond group. the maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). 0 2 0 0 720 from to description 1 32767 each value is a 5 second period. 2 kwh meter report period if the setting is configured for 1hour (set value =6), the pan04 will report its accumulated power consumption (kw/h) every 1 hour to the node of correspond group. the maximum interval to report its accumulated power consumption (kw/h) is 227.55 days (10min*32767/1440=227.55 days). 0 2 0 0 6 from to description 1 32767 each value is one 10 minute period. 4 edge or pulse mode or edge toggl e mode edge mode: this mode is suitable for the bi stable wall switch that has indicator point on the switch, and the same position correspond to same state of relay1 and relay2. if the pan04 relay change the state because of receiving z wave rf command, it may need two times of change (switch on to off or switch off to on) to let relay back to the correspond state. pulse mode: this mode is suitable for the toggle type wall switch to swap the state of relay1 or relay2. edge toggle mode: this mode is suitable for the normal bi stable switch, every time when change the state of the wall switch will also swap the state of relay1 or relay2. 0 1 0 0 1 from to description 1 1 edge mode 2 2 pulse mode 3 3 edge toggle mode 9 rf off command mode whenever a switch off command, basic set 、 binary switch set 、 switch all off, is received, it could be interpreted as 4 kinds of commands. 1. switch off : it switches to off state. the default setting is switch off. 2. ignore : the switch off command will be ignored. 3. switch toggle : it switches to the inverse of current state. 4. switch on : it switches to on state. 0 1 0 0 0 from to description 0 0 switch off 1 1 ignore 2 2 switch toggle 3 3 switch on 10 existence of endpoint3 multi channel command is a good way to control relay1 and relay2 of pan04 individually. the endpoint3 of pan04 is related to both relay1 and relay2. in some condition it becomes redundant in multi channel command class. when the existence of endpoint3 is set as 2, the endpoint3 will be disabled. the default value is 1. endpoint1 and endpoint2 are fixed, only endpoint3 is dynamic. 0 1 0 0 1 from to description 1 1 endpoint 3 exists 2 2 no endpoint 3 5 threshold of current for load caution this is a warning when the current of load over the preset threshold value, if the setting value is 750, when the load current of relay1 or relay2 over this value, pan04 will send current meter report to the node of correspond group, the range of the setting value is from 10 to 750, and the default value is 750. 0 2 0 0 750 from to description 10 750 each value is 0.01 a, e.g. 750*0.01 a = 7.5 a 6 threshold of kwh for load caution this is a warning when the kwh of load over the preset threshold value, if the setting value is 10000, when the accumulated power consumption of relay1 or relay2 over this value, pan04 will send kwh meter report command to the node of correspond group, minimum value is 1 kwh and default value is 10000 k wh. 0 2 0 0 10000 from to description 1 10000 kwh load caution meter report threshold value 7 restore switch state mode whenever the ac power return from lost, pan04 will restore the switch state which could be switch off、last switch state、switch on. the default setting is last switch state. 0 1 0 0 1 from to description 0 0 switch off 1 1 last switch state 2 2 switch on 8 auto off timer whenever pan11 switches to on, the auto off timer begin to count down. after the timer decrease to zero, it will switch off automatically. however if auto off timer is set as 0, the auto off function will be disabled. the default setting is 0. 0 2 0 0 0 from to description 0 0 disable auto off function 1 32767 each value is the number of seconds for the auto off timer. textsID Description Value 1