Long descriptionQubino Mini Dimmer enables you to remotely control and dim all types of dimmable bulbs. It perfectly works on both the 2-wire system - (without neutral) and in a 3-wire system (with neutral). Its small size allows easy installation for professional installers and DIY users. With Mini Dimmer, you can connect and remotely control low wattage bulbs. There is no minimum load power required. From to description 0 0 momentary 1 1 on/off toggle switch 5 parameter no. 5 – working mode with this parameter, you can change the device presentation on the user interface. values (size is 1 byte dec): • default value 0 • 0 dimmer mode • 1 switch mode ⓘ note: after parameter change, first exclude the device (without setting parameters to default value) then wait at least 30s before reinclusion. 1 1 0 1 0 from to description 0 0 dimmer mode 1 1 switch mode 11 parameter no. 11 turn load 1 ( ) off automatically with timer if load ( ) is on, you can schedule it to turn off automatically after a period of time defined in this parameter. the timer is reset to zero each time the device receives an on or off command, either remotely (from the gateway (hub) or associated device) or locally from the switch. values (size is 2 byte dec): • default value 0 • 0 auto off disabled • 1 32536 = 1 32536 seconds auto off timer enabled for a given number of seconds. 1 2 0 32536 0 from to description 0 0 auto off disabled 1 32536 auto off timer enabled for a given number of seconds 60 parameter no. 60 – minimum dimming value the value set in this parameter determines the minimum dimming value (the lowest value which can be set on the device, when, for example, dimming lights with wall switch or slider in the gui (gateway hub)). values (size is 1 byte dec): • default value 0 = 0 % (minimum dimming value) • 1 98 = 1 % 98 %, step is 1 %. minimum dimming value is set by entering a value. ⓘ note: the minimum level may not be higher than the maximum level! 0 % min. dimming value is defined by the z wave multilevel device class. 1 1 0 98 0 from to description 0 0 0 % (minimum dimming value) 1 98 1 % 98 %, step is 1 %. minimum dimming value is set by entering a value. 71 parameter no. 71 – calibration trigger choose when will be the calibration procedure triggered. values (size is 1 byte dec): • default value 0 calibration done after power cycle if module is excluded • 1 – calibration done after power cycle regardless of inclusion status • 2 – force calibration. calibration will start immediately note: for additional information check ‘mini dimmer calibration’ under chapter 11. 1 1 0 2 0 from to description 0 0 calibration done after power cycle if module is excluded 1 1 calibration done after power cycle regardless of inclusion status 2 2 force calibration. calibration will start immediately 68 parameter no. 68 – dimming duration choose the time during which the device will transition from the current value to the new target value. this parameter applies to the association group 3. values (size is 1 byte dec): • default value 0 (dimming duration according to parameter 66) • 1 127 (from 1 to 127 seconds) ⓘ note: parameter is valid only in dimmer mode. in switch mode the parameter has no effect. 1 1 0 127 0 from to description 0 0 (dimming duration according to parameter 66) 1 127 (from 1 to 127 seconds) ⓘ note: parameter is valid only in dimmer mode. in switch mode the parameter has no effect. 61 parameter no. 61 – maximum dimming value the value set in this parameter determines the maximum dimming value (the highest value which can be set on the device, when, for example, dimming lights with wall switch or slider in the gui (gateway hub)). values (size is 1 byte dec): • default value 99 = 99 % (maximum dimming value) • 2 99 = 2 % 99 %, step is 1 %. maximum dimming value is set by entering a value. ⓘ note: the maximum level may not be lower than the minimum level! 99% max. dimming value is defined by the z wave multilevel device class. 1 1 2 99 99 from to description 99 99 99 % (maximum dimming value) 2 99 2 % 99 %, step is 1 %. maximum dimming value is set by entering a value. 66 parameter no. 66 – dimming time when key hold choose the time during which the dimmer will move between the min. and max. dimming values during a continuous press of the push button i1, by an associated device or through the ui controls (basic set, switch multilevel set). values (size is 2 byte dec): • default value 3 = 3 s • 1 127 = 1 second – 127 seconds • 128 – 253 = 1 minute – 126 minutes 1 2 1 253 3 from to description 1 127 1 second – 127 seconds 128 253 1 minute – 126 minutes 70 parameter no. 70 overload safety switch the function allows for turning off the controlled device in case of exceeding the defined power for more than 5s. controlled device can be turned back on by input i1 or sending a control frame. values (size is 2 byte dec): • default value 200 • 1 – 200 = 1 w – 200 w • 0 = function not active ⓘ note: this functionality is not an overload safety protection, please check the technical specifications chapter for more details. in case of overload the following message will be send towards the controller: • command class notification v5 • the alarm v1 type field set to 0x00 • notification type 0x08 and 0x08 (overload detected) 1 2 0 200 200 from to description 1 200 1 w – 200 w 0 0 function not active 67 parameter no. 67 – ignore start level choose whether the device should use (or disregard) the start dimming level value. if the device is configured to use the start level, it should start the dimming process from the currently set dimming level. this parameter is used with association group 3. values (size is 1 byte dec): • default value 0 • 0 – use the start level value • 1 ignore the start level value ⓘ note: parameter is valid only in dimmer mode. in switch mode the parameter has no effect. 1 1 0 1 0 from to description 0 0 use the start level value 1 1 ignore the start level value 65 parameter no. 65 – dimming time when key pressed (soft on/off) choose the time during which the device will move between the min. and max. dimming values by a short press of the push button i1. values (size is 1 byte dec): • default value 1 = 1 s • 1 127 = 1 seconds 127 seconds, step is 1 second 1 1 1 127 1 from to description 1 1 1 s 1 127 1 seconds 127 seconds, step is 1 second 73 parameter no. 73 – alarm/notification events this parameter defines the module behaviour in case it receives any alarm/notification events. values (size is 1 byte dec): • default value 0 – function not active • 1 – turn on • 2 – turn off • 3 – start blinking (output turns 1 s on, and 1 s off) ⓘ note: when value 3 is selected the default time interval of the blinking is 10 minutes. it can be stopped with a button press or sending a control frame. to adjust the time interval please refer to parameter 74 – alarm/notification time interval. 1 1 0 3 0 from to description 0 0 default value 0 – function not active 1 1 turn on 2 2 turn off 3 3 start blinking (output turns 1 s on, and 1 s off) 72 parameter no. 72 – calibration status (read only) parameter no. 72 – calibration status (read only) whit this parameter you can check the calibration status. values (size is 1 byte dec): • default value 2 – calibration failed • 1 – calibration was successful • 2 – calibration failed 1 1 1 2 2 from to description 1 1 calibration was successful 2 2 calibration failed 74 parameter no. 74 – alarm/notification time interval (dependant on parameter 73) this parameter defines the time interval of the blinking state, once the module receives an alarm/notification event. minimum step increase is 1 minute. values (size is 1 byte dec): • default value 10 = 10 minutes • 1 – 125 = 1 125 minutes ⓘ note: this parameter does not have any effect if parameter 73 is not set to value 3. 1 1 1 125 10 from to description 1 125 1 125 minutes 10 10 10 minutes textsID Description Value 1