✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if SE Devices shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Community photos
Photos from members
No member photos yet.
Reviews
What members say
Sign in to rate Standalone Relay 2-Pole and share a photo.
No reviews yet.
Community
Be the first to start a thread about Standalone Relay 2-Pole
Threads post into the SE Devices community forum.
Sign in to start a thread in the SE Devices community.
Edit history
Loading edit history…
Certified
The Standalone 2-Pole Relay is exclusively Z-Wave controllable, and designed to handle loads up to 1800W and be concealed inside Wall Boxes. The Relay switches both Live and Neutral phase, and makes it suitable for use in installation where this is required. The Relay can be used to switch both Heat Sources and Light fixtures. The product also contains a fail-safe mechanism which will switch the relay ON and OFF at fixed intervals, in case communication from a controlling device is lost. The Relay measures the immediate and accumulated power consumption of an attached load, which is reported at fixed intervals.
Want to buy adds it to your wish list and follows SE Devices for updates. I own it adds it to your collection.
The Standalone 2-Pole Relay is exclusively Z-Wave controllable, and designed to handle loads up to 1800W and be concealed inside Wall Boxes. The Relay switches both Live and Neutral phase, and makes it suitable for use in installation where this is required. The Relay can be used to switch both Heat Sources and Light fixtures. The product also contains a fail-safe mechanism which will switch the relay ON and OFF at fixed intervals, in case communication from a controlling device is lost. The Relay measures the immediate and accumulated power consumption of an attached load, which is reported at fixed intervals.
Hardware platform
ZM5202
Short description
Z-Wave controllable Standalone 1-Pole Relay (1800W) designed to be concealed in wall boxes.
Product identifier
AR2P
Countries / regions
European Union
Certification number
ZC10-18046086
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 4
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported multilevel sensors
Multilevel Sensor Type Power
Supported / controlled meter types
Meter Type Rate Type Description Electric meter
Value electric energy firmware updatable value updatable by professional/technician switch load capacity current value 7.85 switch load capacity watts value 1800 neutral wire required sensors value power voltage current electric load type value incandescent fluorescent mlv (magnetic) led inductive (e.g. motor) association groups
Group Number Maximum Nodes Supported End Point ID Description 2
From to description 0 32767 safety activation delay 5 safety off period the number of seconds to stay in off mode when safety is activated. the back unit turns on when the timer have elapsed. if value is 0, the back unit will not turn back on. the max limit is 32767 seconds (9 hours, 6 minutes and 7 seconds) 0 2 0 0 600 from to description 0 32767 safety off period 6 safety on period the number of seconds to stay in on mode when safety is activated. the back unit turns back off when the timer have elapsed (and continues to turn on and off alternately). if value is 0, the back unit will not turn on at all. the max limit is 32767 seconds (9 hours, 6 minutes and 7 seconds) 0 2 0 0 300 from to description 0 32767 safety on period texts