✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if HELTUN shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Community photos
Photos from members
No member photos yet.
Reviews
What members say
Sign in to rate Fan Coil Thermostat and share a photo.
No reviews yet.
Community
Be the first to start a thread about Fan Coil Thermostat
Threads post into the HELTUN community forum.
Sign in to start a thread in the HELTUN community.
Edit history
Loading edit history…
Certified
The HE-FT01 is HELTUN’s advanced programmable Z-Wave thermostat for heating/cooling systems such as fan coil units, floor convectors, and wall, window, or ceiling mounted air conditioning units. The HE-FT01 thermostat is ‘impossibly thin’ on the wall while still being packed full of features, delivering highly accurate comfort control through proprietary technology and four built-in sensors. You can monitor and control the HE-FT01 from anywhere in the world using a Z-Wave hub and your smartphone.* And because it uses Z-Wave Plus version 2, Smart Start, S2 Security and 700 platform technologies, the HE-FT01 can be placed up to 100 meters away from the hub and is a snap to install. Best of all, the built-in Power Consumption System precisely monitors how much energy you used during any particular day, week or month, helping you save money on energy costs while staying comfortable all year long. The HELTUN HE-FT01 is part of an entire line of smart, connected products designed to provide the best technology has to offer without compromising stylish living. (*hub and smartphone not included)
Want to buy adds it to your wish list and follows HELTUN for updates. I own it adds it to your collection.
The HE-FT01 is HELTUN’s advanced programmable Z-Wave thermostat for heating/cooling systems such as fan coil units, floor convectors, and wall, window, or ceiling mounted air conditioning units. The HE-FT01 thermostat is ‘impossibly thin’ on the wall while still being packed full of features, delivering highly accurate comfort control through proprietary technology and four built-in sensors. You can monitor and control the HE-FT01 from anywhere in the world using a Z-Wave hub and your smartphone.* And because it uses Z-Wave Plus version 2, Smart Start, S2 Security and 700 platform technologies, the HE-FT01 can be placed up to 100 meters away from the hub and is a snap to install. Best of all, the built-in Power Consumption System precisely monitors how much energy you used during any particular day, week or month, helping you save money on energy costs while staying comfortable all year long. The HELTUN HE-FT01 is part of an entire line of smart, connected products designed to provide the best technology has to offer without compromising stylish living. (*hub and smartphone not included)
Hardware platform
ZGM130
Short description
Advanced Programmable Z-Wave Plus v2 Thermostat for Fan Coil Heating/Cooling Systems—with S2 security and Smart Start on the Z-Wave 700 platform.
Product identifier
HE-FT01
Countries / regions
India, Malaysia, Singapore, United Arab Emirates, Brazil, Russian Federation, Australia, Japan, China, European Union, South Africa, Chile, Republic of Korea, Israel, United States of America, Hong Kong
Supports smart start
Yes
Certification number
ZC12-20010025
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_CONFIGURATION_V4
Supported multilevel sensors
Multilevel Sensor Type Air temperature
Supported / controlled meter types
Meter Type Rate Type Description Electric meter
Value updatable by consumer by rf thermostat hvac systems supported value heat only cool only ventilation control multi stage thermostat modes value heat cool auto fan only auto changeover energy save heat energy save cool thermostat power source value power stealing (hard wired 24 v) mains powered (120 v/240 v) switch type value dry contact neutral wire required switch load capacity current value 5x5 a association groups
Group Number Maximum Nodes Supported End Point ID Group Name Profile Description 1
From to description 0 0 switch off auto correction 1 0 if thermostat is connected to a z wave gateway, the time and day will be periodically polled and corrected from the gateway 2 time format time format 3 1 0 1 1 from to description 0 0 24 hour format 1 0 12 hour (am/pm) format 6 degree mode degree mode (c/f) floor and air temperature, as well as set point and all parameters will be indicated in the chosen mode. factory default value is degrees celsius (0). 3 1 0 1 0 from to description 0 0 celsius 1 0 fahrenheit 31 sensors report time sensors consecutive reporting interval, minutes. when the device is connected to the z wave gateway (controller), it periodically sends to the gateway reports from its room & floor temperature, humidity and light sensors even if there are not changes in the values. this parameter defines the interval between consecutive reports. the value can be adjusted from 1 min to 120 min. note: if the sensor readings change, the device will send the report to the gateway regardless of this parameter value. in order not to increase traffic on your network, it is not recommended to reduce the value of this parameter. we recommend to reduce the value of this parameter only in case of poor connection, when reports from the device does not always reach the gateway. 2 1 1 120 10 from to description 1 120 the value can be adjusted from 1 to 120 minutes 3 weekday week day. this parameter allows manually adjustment of the day of the week in case if the thermostat is not connected to any z wave gateway or parameter 09 (auto correction) is selected as 0. 3 1 1 7 1 from to description 1 0 monday 2 0 tuesday 3 0 wednesday 4 0 thursday 5 0 friday 6 0 saturday 7 0 sunday 4 hour this parameter allows manual adjustment of time in hours (24 hours). 2 1 0 23 0 from to description 0 23 manual adjustment of time hours (24 hours). 5 minute this parameter allows manual adjustment of the time in minutes (60 minutes)) 2 1 0 59 0 from to description 0 59 manual adjustment of time minutes (60 minutes) 44 evening start time evening start time for the temperature schedules. format: hhmm. e.g.08:00 should be sent as 0800. 2 2 0 2359 1800 from to description 0 2359 evening start time. format: hhmm (from 00:00 to 23:59) 45 night start time night start time for the temperature schedules. format: hhmm. e.g.08:00 should be sent as 0800. 2 2 0 2359 2300 from to description 0 2359 night start time. format: hhmm (from 00:00 to 23:59) 9 auto brightness display auto brightness control the he ft01 can adjust its display brightness automatically depending on the ambient room brightness. 3 1 0 1 1 from to description 0 0 manual control: inactive level brightness will be set to the level defined by parameter 10. 1 0 automatic brightness control. 8 temp hysteresys this parameter defines the hysteresis value for temperature control. the he ft01 will stabilize the temperature with the selected hysteresis. for example, if the set point is set for 25°c and hysteresis is set for 0.5°c, the he ft01 will change the state to idle if the temperature reaches 25.0°c. it will change the state to heating if the temperature becomes lower than 24.5°c, and will change the state to cooling if the temperature rises beyond 25.5°c. the hysteresis value can be changed from 0.2°c to 10.0°c range in celsius mode, and 0.3°f to 18.0°f in fahrenheit. the factory default value is 0.5°c (0.9°f). 2 1 2 100 5 from to description 2 100 temperature hysteresis value (°c x 10) 17 reserved parameter reserved by the manufacturer. setting this parameter will have no impact on dut functionality. 2 1 0 1 0 from to description 0 1 parameter reserved by the manufacturer. setting this parameter will have no impact on dut functionality. 23 reserved parameter reserved by the manufacturer. setting this parameter will have no impact on dut functionality. 2 1 0 1 0 from to description 0 1 parameter reserved by the manufacturer. setting this parameter will have no impact on dut functionality. 24 reserved parameter reserved by the manufacturer. setting this parameter will have no impact on dut functionality. 2 1 0 1 0 from to description 0 1 parameter reserved by the manufacturer. setting this parameter will have no impact on dut functionality. 25 reserved parameter reserved by the manufacturer. setting this parameter will have no impact on dut functionality. 2 1 0 1 0 from to description 0 1 parameter reserved by the manufacturer. setting this parameter will have no impact on dut functionality. 41 time mode operation this parameter determines the climate mode (heating or cooling) to which he ft01 will switch when the time operating mode is selected. 3 1 1 3 1 from to description 1 0 the thermostat will go to heating & cooling mode 2 0 the thermostat goes to heating mode 3 0 the thermostat goes to cooling mode 42 morning start time morning start time for the temperature schedules. format: hhmm. e.g.08:00 should be sent as 0800. 2 2 0 2359 600 from to description 0 2359 morning start time. format: hhmm (from 00:00 to 23:59) 43 day start time day start time for the temperature schedules. format: hhmm. e.g.08:00 should be sent as 0800. 2 2 0 2359 900 from to description 0 2359 day start time. format: hhmm (from 00:00 to 23:59) 7 air temp correction this parameter defines the offset value for room air temperature. if the internal air temperature sensor is not correctly calibrated, then manual calibration can be accomplished by adjusting the values up to ±9.5°c (±17°f). this value will be added or subtracted from the internal air temperature sensor reading. 1 1 95 95 0 from to description 95 95 air temperature offset value (°c x 10) texts