Long descriptionFlush 2 relays module is used for switching on or off two electrical devices (e.g. lights, fans, etc ...). The module can be controlled either through Z-Wave network or through the wall switches. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module measures power consumption of two electrical devices and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network. From to description 0 0 mono stable switch type (push button) 1 1 bi stable switch type 43 power reporting in watts by time interval for q2 set value means time interval (0 – 32535) in seconds, when power report is send. 0 2 0 0 300 from to description 0 0 reporting disabled 1 32535 = 1 second – 32535 seconds. reporting enabled, power report is send with time interval set by entered value. 63 output q1 switch selection set value means the type of the device that is connected to the q1 output. the device type can be normally open (no) or normally close (nc). 0 1 0 0 0 from to description 0 0 when system is turned off the output is 0 v (nc). 1 1 when system is turned off the output is 230 v (no). 42 power reporting in watts by time interval for q1 set value means time interval (0 – 32535) in seconds, when power report is send. 0 2 0 0 300 from to description 0 0 reporting disabled 1 32535 = 1 second – 32535 seconds. reporting enabled, power report is send with time interval set by entered value. 120 digital temperature sensor reporting if digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. 0 1 0 0 5 from to description 0 0 reporting disabled 1 127 0,1 deg.c 12.7 deg.c. step is 0,1 deg.c 41 power reporting in watts on power change for q2 set value means percentage, set value from 0 – 100 = 0% 100% 0 1 0 0 10 from to description 0 0 reporting disabled 1 100 1% 100% reporting enabled. power report is send (push) only when actual power in watts in real time changes for more than set percentage comparing to previous actual power in watts, step is 1%. note: if power changed is less than 1 w, the report is not send (pushed), independent of percentage set. 64 output q2 switch selection set value means the type of the device that is connected to the q2 output. the device type can be normally open (no) or normally close (nc). 0 1 0 0 0 from to description 0 0 when system is turned off the output is 0 v (nc). 1 1 when system is turned off the output is 230 v (no). 110 temperature sensor offset settings set value is added or subtracted to actual measured value by sensor. 0 2 0 0 32536 from to description 32536 32536 offset is 0.0 deg.c 1 100 value from 0.1 deg.c to 10.0 deg.c is added to actual measured temperature. 1001 1100 value from 0.1 deg.c to 10.0 deg.c is subtracted to actual measured temperature. 1 input 1 switch type input 1 switch type 0 1 0 0 1 from to description 1 1 bi stable switch type 0 0 mono stable switch type (push button) 11 automatic turning off output q1 after set time when relay q1 is on it goes automatically off after time defined by this parameter. timer is reset to zero each time the module receive on command regardless from where it comes (push button, associated module, controller,..). 0 2 0 0 0 from to description 0 0 auto off disabled 1 32535 1second (0,01s) – 32535 seconds (325,35s) auto off enabled with define time, step is 1s or 10ms according to parameter nr.15 10 activate / deactivate functions all on/all off activate / deactivate functions all on/all off flush 2 relays module responds to commands all on / all off that may be sent by the main controller or by other controller belonging to the system. 0 2 0 0 255 from to description 255 255 all on active, all off active 0 0 all on is not active all off is not active 1 1 all on is not active all off active 2 2 all on active all off is not active textsID Description Value 1