Long descriptionThis Z-Wave module is used to control the motor of blinds, rollers, shades, venetian blinds, etc … The module can be controlled either through a Z-Wave network or through the wall switch. Precise positioning is supported for motors equipped with mechanical or electronic end switches. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module measures power consumption of motor and support connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-Wave network. Short descriptionThe Qubino Flush Shutter is the world's smallest Z-Wave module able to control the motors of blinds, rollers, shades, venetian blinds, etc. From to description 1 1 slats return to previously set position in case of z wave control, push button operation or when the lower limit switch is reached 0 0 slats return to previously set position only in case of z wave control (not valid for limit switch positions) 10 activate/deactivate functions all on / all off flush shutter responds to commands all on / all off that may be sent by the main controller or by other controllers belonging to the system. 0 2 0 0 255 from to description 2 2 all on active all off is not active 0 0 all on is not active all off is not activ 1 1 all on is not active all off active 255 255 all on active, all off active 42 power reporting in watts by time interval for q1 or q2 set value means time interval (0 – 32767) in seconds, when power report is send. 0 2 0 0 0 from to description 1 32767 = 1 second 32767 seconds. reporting enabled, power report is send with time interval set by entered value 0 0 reporting disabled 71 operating modes this parameter defines selection between two available operating modes. note1: after parameter change, first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module! 0 1 0 0 0 from to description 1 1 venetian mode (up/down and slate rotation) 0 0 shutter mode 72 slats tilting full turn time this parameter defines the time necessary for slats to make full turn (180 degrees). 0 2 0 0 150 from to description 0 0 tilting time disabled 2 32767 = 0,01seconds 327,67 seconds 150 150 = 1,5 seconds 74 motor moving up/down time this parameter defines shutter motor moving time of complete opening or complete closing. note: important is that the reference position to manually set moving time is always shutter lower position! set parameter 74 to 0 and move the shutter (using up/down push buttons or main controller ui) to the lowest desired position. on this shutter position, set parameter 74 to time for complete opening or complete closing. at this point shutter can be moved up (open) for set time, but can't be moved down because this position is already set as lower shutter position. to change shutter lower position below already set (manual recalibration), parameter 74 must be set to 0 and repeat the procedure described above. in case shutter has limit switches, but anyhow you would like to limit opening/closing position by time, you can still do it. in case you put time that is longer that opening/closing real time limited by limit switches, shutter will stop at limit switch, but the module relay will switch off after define time, not by shutter limit switch. take in consideration that in this condition, the positioning with slider through ui will not show correct shutter position. 0 2 0 0 0 from to description 0 0 moving time disabled (working with limit switches) 1 32767 = 0,1 seconds 3276,7 seconds. after that time motor is stopped (relay goes to off state) 78 forced shutter calibration by modifying the parameters setting from 0 to 1 a shutter enters the calibration mode. 0 1 0 0 0 from to description 0 0 1 1 start calibration process (when calibration process is finished, completing full cycle up, down and up, set the parameter 78 (forced shutter calibration) value back to 0 110 temperature sensor offset settings set value is added or subtracted to actual measured value by sensor. 0 2 0 0 32536 from to description 32536 32536 offset is 0.0 degrees celsius 1 100 value from 0.1 degrees celsius to 10.0 degrees celsius is added to actual measured temperature 1001 1100 value from 0.1 degrees celsius to 10.0 degrees celsius is subtracted to actual measured temperature 120 temperature sensor reporting if digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. available configuration parameters (data type is 1 byte dec): • default value 5 = 0,5°c • 0 reporting disabled • 1 127 = 0,1°c 12,7°c, step is 0,1°c 0 1 0 0 5 from to description 5 5 = 0,5 degrees celsius 0 0 reporting disabled 1 127 = 0,1 degrees celsius 12,7 degees celsius; step is 0,1 degrees celsius 250 unsecure / secure inclusion flush shutter supports secure and unsecure inclusion. even if the controller does not support security command classes, a dimmer could be included as unsecure and keep all the functionality. 0 1 0 0 0 from to description 0 0 unsecure inclusion 1 1 secure inclusion textsID Description Value 2