✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if QUBINO shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Community photos
Photos from members
No member photos yet.
Reviews
What members say
Sign in to rate Qubino Flush 1D relay and share a photo.
No reviews yet.
Community
Be the first to start a thread about Qubino Flush 1D relay
Threads post into the QUBINO community forum.
Sign in to start a thread in the QUBINO community.
Edit history
Loading edit history…
Certified
Qubino Flush 1D relay with voltage free (dry contact) output contact. This Z-Wave module is used for switching on or off the electrical device (e.g. light, fan, etc ...). The module can be controlled either through Z-wave network or through the wall switch. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network. Output contact is voltage free (dry contact), so also loads with different power supply can be connected to the module. FEATURES: - The module has the option to connect a digital temperature sensor - small dimensions (WxHxD) 41,8x36,8x15,4mm - power supply is 110 - 230 VAC ±10% 50/60Hz, 24-30VDC - Electrical consumption 0,4W
Want to buy adds it to your wish list and follows QUBINO for updates. I own it adds it to your collection.
Qubino Flush 1D relay with voltage free (dry contact) output contact. This Z-Wave module is used for switching on or off the electrical device (e.g. light, fan, etc ...). The module can be controlled either through Z-wave network or through the wall switch. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network. Output contact is voltage free (dry contact), so also loads with different power supply can be connected to the module. FEATURES: - The module has the option to connect a digital temperature sensor - small dimensions (WxHxD) 41,8x36,8x15,4mm - power supply is 110 - 230 VAC ±10% 50/60Hz, 24-30VDC - Electrical consumption 0,4W
Hardware platform
ZM5202
Short description
Qubino Flush 1D relay is used for switching On or Off the electrical device. Output contact is voltage free (dry contact), so also loads with different power supply can be connected to the module.
Association groups
Group Number Maximum Nodes Supported End Point ID Description 1
Product identifier
ZMNHN
Countries / regions
European Union
Certification number
ZC10-15070017
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 1
Supports explorer frames
Yes
From to description 1 1 bi stable switch type 0 0 mono stable switch type (push button) 2 input 2 contact type defines the type of switch connected to input 2 0 1 0 0 0 from to description 0 0 no (normally open) input type 1 1 1 nc (normally close) input type 11 automatic turning off output after set time support automatic turning off output after set time. when relay is on it goes automatically off after time defined by this parameter. timer is reset to zero each time the module receive on command regardless from where it comes (push button, associated module, controller,..). 0 2 0 0 0 from to description 1 32535 1 – 32535 = 1second (0,01s) – 32535 seconds (325,35s) auto off enabled with define time, step is 1s or 10ms according to parameter nr.15 0 0 auto off disabled 10 activate / deactivate functions all on/all off support to activate / deactivate functions all on/all off flush 1 d relay module responds to commands all on / all off that may be sent by the main controller or by other controller belonging to the system. 0 2 0 0 255 from to description 255 255 all on active, all off active 0 0 all on is not active all off is not active 1 1 all on is not active all off active 2 2 all on active all off is not active 63 output switch selection support output switch selection set value means the type of the device that is connected to the output. the device type can be normally open (no) or normally close (nc). 0 1 0 0 0 from to description 1 1 when system is turned off the output is 230 v or 24 v (no). 0 0 when system is turned off the output is 0 v (nc). 100 enable / disable endpoint i2 or select notification type and event support enable / disable endpoint i2 or select notification type and event enabling i2, means that endpoint (i2) will be present on ui. disabling it will result in hiding the endpoint according to the parameter set value. additionally, a notification type and event can be selected for the endpoint. note: after parameter change module has to be reincluded into the network for the setting to take effect! 0 1 0 0 1 from to description 0 0 endpoint, i2 disabled 4 4 water alarm; water leak detected, unknown location. 6 6 smoke alarm; smoke detected, unknown location. 3 3 carbon dioxide; carbon dioxide detected, unknown location. 1 1 home security; motion detection, unknown location 5 5 heat alarm; overheat detected, unknown location. 2 2 carbon monoxide; carbon monoxide detected, unknown location. 110 temperature sensor offset settings defines temperature sensor offset settings set value is added or subtracted to actual measured value by sensor. 0 2 0 0 32536 from to description 1 100 value from 0.1 c to 10.0 c is added to actual measured temperature. 32536 32536 offset is 0.0 c 1001 1100 value from 0.1 c to 10.0 c is subtracted to actual measured temperature. 120 digital temperature sensor reporting defines the digital temperature sensor reporting if digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. 0 1 0 0 5 from to description 0 0 reporting disabled 1 127 0,1 c – 12,7 c, step is 0,1 c texts