Zula is a MOSFET-switching light device that supports the control of low-voltage halogen lamps with electronic transformers, dimmable compact fluorescent lights, and dimmable LED bulbs. It measures power consumption of the connected device. It supports momentary switches (by default) and toggle switches. It can work with or without the neutral line. Master Zula allows the easiest and quickest installation in all types of flush mounting boxes. Master Zula also acts as a Z-Wave™ repeater to improve the range and stability of the Z-Wave™ network.
Want to buy adds it to your wish list and follows Master for updates. I own it adds it to your collection.
✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Master shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Zula is a MOSFET-switching light device that supports the control of low-voltage halogen lamps with electronic transformers, dimmable compact fluorescent lights, and dimmable LED bulbs. It measures power consumption of the connected device. It supports momentary switches (by default) and toggle switches. It can work with or without the neutral line. Master Zula allows the easiest and quickest installation in all types of flush mounting boxes. Master Zula also acts as a Z-Wave™ repeater to improve the range and stability of the Z-Wave™ network.
Hardware platform
ZM5101
Short description
Zula is a MOSFET-switching light device that also supports control of low-voltage halogen lamps with electronic transformers, dimmable compact fluorescent lights, and dimmable LED bulbs. It can work with or without the neutral line (3 or 2-wire installation).
Product identifier
HZ61100
Countries / regions
Australia
Certification number
ZC10-21127066
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 72
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported notification types
Notification Type Event / State Power Management
Supported / controlled meter types
Meter Type Rate Type Description Electric meter
Value antique brass communications protocol value manufacturer proprietary protocol electric load type neutral wire required outdoor use switch load capacity current switch load capacity watts switch type value decorator paddle push association groups
Group Number Maximum Nodes Supported End Point ID Group Name Description 1
From to description 1 1 calibration was successful 2 2 calibration failed 1 parameter no. 1 – in wall switch type for load ( ) to control terminal i with this parameter, you can select between momentary and on/off toggle switch types. values (size is 1 byte dec): • default value 0 • 0 momentary switch • 1 on/off toggle switch 1 1 0 1 0 from to description 0 0 momentary switch 1 1 on/off toggle switch 5 parameter no. 5 – working mode with this parameter, you can change the device presentation on the user interface. values (size is 1 byte dec): • default value 0 • 0 dimmer mode • 1 switch mode ⓘ note: after parameter change, first exclude the device (without setting parameters to default value) then wait at least 30 seconds before re inclusion. 1 1 0 1 0 from to description 0 0 dimmer mode 1 1 switch mode 11 parameter no. 11 turn load ( ) off automatically with timer if load ( ) is on, you can schedule it to turn off automatically after a period of time defined in this parameter. the timer is reset to zero each time the device receives an on or off command, either remotely (from the gateway (hub) or associated device) or locally from the switch. values (size is 2 byte dec): • default value 0 • 0 auto off disabled • 1 32536 = 1 32536 seconds auto off timer enabled for a given amount of seconds 1 2 0 32536 0 from to description 0 0 auto off disabled 1 32536 1 32536 seconds auto off timer enabled for a given amount of seconds 61 parameter no. 61 – maximum dimming value the value set in this parameter determines the maximum dimming value (the highest value which can be set on the device, when, for example, dimming lights with wall switch or slider in the gui (gateway hub)). values (size is 1 byte dec): • default value 99 = 99 % (maximum dimming value) • 1 99 = 2 % 99 %, step is 1 %. maximum dimming value is set by entering a value. ⓘ note: the maximum level may not be lower than the minimum level! 1 1 1 99 99 from to description 1 99 2 % 99 %, step is 1 %. maximum dimming value is set by entering a value 65 parameter no. 65 – dimming time when key pressed (soft on/off) choose the time during which the device will move between the min. and max. dimming values by a short press of the momentary switch connected to terminal i. values (size is 1 byte dec): • default value 1 = 1 s • 1 127 = 1 seconds 127 seconds, step is 1 second 1 1 1 127 1 from to description 1 127 1 seconds 127 seconds, step is 1 second 66 parameter no. 66 – dimming time when key holdwag choose the time during which the dimmer will move between the min. and max. dimming values during a continuous press of the momentary switch connected to terminal i, by an associated device or through the ui controls (basic set, switch multilevel set). values (size is 2 byte dec): • default value 3 = 3 seconds • 1 127 = 1 second – 127 seconds • 128 – 253 = 1 minute – 126 minutes 1 2 1 253 3 from to description 1 127 1 second – 127 seconds 128 253 1 minute – 126 minutes 67 parameter no. 67 – ignore start level choose whether the device should use (or disregard) the start dimming level value. if the device is configured to use the start level, it should start the dimming process from the currently set dimming level. this parameter is used with association group 3. values (size is 1 byte dec): • default value 0 • 0 – use the start level value • 1 ignore the start level value ⓘ note: parameter is valid only in dimmer mode. in switch mode the parameter has no effect. 1 1 0 1 0 from to description 0 0 use the start level value 1 1 ignore the start level value 68 parameter no. 68 – dimming duration for associations choose the time during which the device will transition from the current value to the new target value. this parameter applies to the association group 3. values (size is 1 byte dec): • default value 0 (dimming duration according to parameter 66) • 1 127 (from 1 to 127 seconds) ⓘ note: parameter is valid only in dimmer mode. in switch mode the parameter has no effect. 1 1 0 127 0 from to description 1 127 (from 1 to 127 seconds) 70 parameter no. 70 overload safety switch the function allows for turning off the controlled device in case of exceeding the defined power for more than 5 s. controlled device can be turned back on by terminal i or sending a control frame. values (size is 2 byte dec): • default value 200 • 1 – 200 = 1 w – 200 w • 0 = function not active ⓘ note: this functionality is not an overload safety protection, please check the technical specifications chapter for more details. in case of overload the following message will be send towards the controller: • command class notification v5 • the alarm v1 type field set to 0x00 • notification type 0x08 and 0x08 (overload detected) 1 2 0 200 200 from to description 0 0 function not active 1 200 1 w – 200 w 71 parameter no. 71 – calibration trigger choose when will be the calibration procedure triggered. values (size is 1 byte dec): • default value 0 calibration done after power cycle if module is excluded • 1 – calibration done after power cycle regardless of inclusion status • 2 – force calibration. calibration will start immediately note: for additional information check ‘zula calibration’ under chapter 2. 1 1 0 2 0 from to description 1 1 calibration done after power cycle regardless of inclusion status 2 2 force calibration. calibration will start immediately 73 parameter no. 73 – alarm/notification events this parameter defines the module behaviour in case it receives any alarm/notification events. values (size is 1 byte dec): • default value 0 – function not active • 1 – turn on • 2 – turn off • 3 – start blinking (output turns 1 s on, and 1 s off) ⓘ note: when value 3 is selected the default time interval of the blinking is 10 minutes. it can be stopped with a button press or sending a control frame. to adjust the time interval please refer to parameter 74 – alarm/notification time interval. 1 1 0 3 0 from to description 1 1 turn on 2 2 turn off 3 3 start blinking (output turns 1 s on, and 1 s off) 74 parameter no. 74 – alarm/notification time interval (dependant on parameter 73) this parameter defines the time interval of the blinking state, once the module receives an alarm/notification event. minimum step increase is 1 minute. values (size is 1 byte dec): • default value 10 = 10 minutes • 1 – 125 = 1 125 minutes ⓘ note: this parameter does not have any effect if parameter 73 is not set to value 3. 1 1 0 125 10 from to description 1 125 1 125 minutes texts