✅ Future-proofBuilt to keep working — even if the maker walks away.
It works locally over Z-Wave, so it keeps running even if Master shuts down the app or the servers. Nothing here ties you to a single company's survival.
Works locally over Z-Wave — keeps running without the maker's cloud
Still in production
Based on how this device connects (local vs. cloud), whether it’s still sold and supported, and its app / subscription. A guide, not a guarantee.
Connectivity
Z-Wave
Prices
No prices yet — be the first to add one.
Community tags
Be the first to tag this page — tags appear right away. Try a theme, capability, or subject (e.g. WWII, heist, slow burn, time travel, A24).
Be the first to start a thread about ZOE SHUTTER E
Threads post into the Master community forum.
Sign in to start a thread in the Master community.
Edit history
Loading edit history…
Certified
The ZOE Shutter E controls the motors of blinds, rollers, shades, venetian blinds, etc. It measures power consumption of the connected device, and can be paired with a digital temperature sensor (sold separately). The connection of a digital temperature sensor means you can create complex scenes and control any device relative to a set temperature range. The ZOE Shutter E also acts as a Z-Wave repeater to improve the range and stability of the Z-Wave network. The ZOE Shutter E can be used in many different scenes, which can help make your life more comfortable. Get an idea for your next smart home project. Of course, there are countless of other options for how to use ZOE Shutter E to remotely control devices via your smartphone.
Want to buy adds it to your wish list and follows Master for updates. I own it adds it to your collection.
The ZOE Shutter E controls the motors of blinds, rollers, shades, venetian blinds, etc. It measures power consumption of the connected device, and can be paired with a digital temperature sensor (sold separately). The connection of a digital temperature sensor means you can create complex scenes and control any device relative to a set temperature range. The ZOE Shutter E also acts as a Z-Wave repeater to improve the range and stability of the Z-Wave network. The ZOE Shutter E can be used in many different scenes, which can help make your life more comfortable. Get an idea for your next smart home project. Of course, there are countless of other options for how to use ZOE Shutter E to remotely control devices via your smartphone.
Hardware platform
ZM5202
Short description
The ZOE Shutter E controls the motors of blinds, rollers, shades, venetian blinds, etc. It measures power consumption of the connected device, and can be paired with a digital temperature sensor (sold separately).
Product identifier
HZ07000
Countries / regions
European Union
Certification number
ZC10-20106992
Radio range z wave (m)
40
Configuration parameters
Parameter Number Name Description Format Size Min Value Max Value Default Value Parameter Values 71
Supports explorer frames
Yes
Supported command classes
Identifier Name Key Version COMMAND_CLASS_POWERLEVEL
Controlled command classes
Identifier Name Key Version COMMAND_CLASS_BASIC
Supported multilevel sensors
Multilevel Sensor Type Air temperature
Supported notification types
Notification Type Event / State Power Management
Supported / controlled meter types
Meter Type Rate Type Description Electric meter
Value inductive (e.g. motor) switch load capacity watts value 920 color value black window covering control features value position aware automatic calibration manual calibration supports horizontal blinds/louvers supports tilt motion supports up/down motion supports open/close motion switch load capacity current value 4 neutral wire required association groups
Group Number Maximum Nodes Supported End Point ID Group Name Description 1
From to description 0 0 shutter mode 1 1 venetian mode (up/down and slate rotation) 72 parameter no. 72 – slats tilting full turn time this parameter defines the time necessary for slats to make full turn (180 degrees). available configuration parameters (data type is 2 byte dec): • default value 150 = 1,5 seconds • 0 tilting time disabled • 1 32767 = 0,01seconds 327,67 seconds note: if time set is too high, this will result that after full turn, shutter will start move up or down, for time remaining 1 2 0 32767 150 from to description 0 0 tilting time disabled 1 32767 0.01seconds – 327.67 seconds 42 parameter no. 42 – power reporting in watts by time interval for q1 or q2 set value means time interval (0 – 32767) in seconds, when power report is send. available configuration parameters (data type is 2 byte dec): • default value 0 = reporting disabled • 0 reporting disabled • 1 32767 = 1 second 32767 seconds. reporting enabled, power report is send with time interval set by entered value. 1 2 0 32767 0 from to description 0 0 power consumption reporting disabled 1 32767 1 32767 seconds. power consumption reporting enabled. report is sent according to time interval (value) set here 78 parameter no. 78 forced shutter calibration by modifying the parameters setting from 0 to 1 a shutter enters the calibration mode. available configuration parameters (data type is 1 byte dec): • default value 0 • 1 start calibration process (when calibration process is finished, completing full cycle up, down and up, set the parameter 78 (forced shutter calibration) value back to 0. 1 1 0 1 0 from to description 1 0 start the calibration process. when the calibration process finishes (completing the full cycle up, down and up again), set the value of the parameter 78 (forced shutter calibration) back to 0. 10 parameter no. 10 activate/deactivate functions all on / all off available config. parameters (data type is 2 byte dec): • default value 255 • 255 all on active, all off active. • 0 all on is not active all off is not active • 1 all on is not active all off active • 2 all on active all off is not active zoe shutter responds to commands all on / all off that may be sent by the main controller or by other controllers belonging to the system. 1 2 0 255 255 from to description 0 0 all on not active, all off not active 1 1 all on not active, all off active 2 2 all on active, all off not active 255 255 all on active, all off active 73 parameter no. 73 – slats position this parameter defines slats position after up/down movement through z wave or push buttons. available configuration parameters (data type is 1 byte dec): • default value 1 • 0 slats return to previously set position only in case of z wave control (not valid for limit switch positions). • 1 slats return to previously set position in case of z wave control, push button operation or when the lower limit switch is reached. 1 1 0 1 0 from to description 1 1 slats return to the previously set position in case they were activated via the z wave gateway (hub), push button operation or when the lower limit switch is reached 0 0 slats return to the previously set position only after being activated via the z wave gateway (hub) (not valid for limit switch positions) 74 parameter no. 74 – motor moving up/down time complete opening or complete closing. available configuration parameters (data type is 2 byte dec): • default value 0 • 0 – moving time disabled (working with limit switches) • 1 32767 = 0,1seconds 3276,7seconds after that time motor is stopped (relay goes to off state) note: important is that the reference position to manually set moving time is always shutter lower position! set parameter 74 to 0 and move the shutter (using up/down push buttons or main controller ui) to the lowest desired position. on this shutter position, set parameter 74 to time for complete opening or complete closing. at this point shutter can be moved up (open) for set time, but can't be moved down because this position is already set as lower shutter position. to change shutter lower position below already set (manual recalibration), parameter 74 must be set to 0 and repeat the procedure described above. in case shutter has limit switches, but anyhow you would like to limit opening/closing position by time, you can still do it. in case you put time that is longer that opening/closing real time limited by limit switches, shutter will stop at limit switch, but the module relay will switch off after define time, not by shutter limit switch. take in consideration that in this condition, the positioning with slider through ui will not show correct shutter position. 1 2 0 32767 0 from to description 0 0 moving time disabled (working with limit switches) 1 32767 0.1 seconds – 3276.7 seconds 110 parameter no. 110 – temperature sensor offset settings set value is added or subtracted to actual measured value by sensor. available configuration parameters (data type is 2 byte dec): • default value 32536 • 32536 offset is 0.0 c • from 1 to 100 value from 0.1 °c to 10.0 °c is added to actual measured temperature. • from 1001 to 1100 value from 0.1 °c to 10.0 °c is subtracted to actual measured temperature. 1 2 0 32536 32536 from to description 1 100 where 1 stands for 0.1°c and 100 stands for 10.0°c added to the actual measurement. 1001 1100 where 1001 stands for 0.1°c and 1100 stands for 10.0°c subtracted from the actual measurement. 32536 32536 offset is 0 °c 120 parameter no. 120 – temperature sensor reporting threshold if digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. available configuration parameters (data type is 1 byte dec): • default value 5 = 0,5°c • 0 reporting disabled • 1 127 = 0,1°c 12,7°c, step is 0,1°c 1 1 0 127 5 from to description 0 0 reporting disabled 1 127 where 1 stands for 0.1°c and 127 stands for 12.7°c. texts